Search results for "Rumen"

showing 10 items of 5946 documents

Acoustic characterization of Silica aerogel clamped plates for perfect absorption purpose

2017

International audience; Silica aerogel has been widely studied as bulk material for its extremely low density and thermal conductivity. Plates or membranes made of this extremely soft materials exhibits interesting properties for sound absorption. A novel signal processing method for the characterization of an acoustic metamaterial made of silica aerogel clamped plates is presented. The acoustic impedance of a silica aerogel clamped plate is derived from the elastic theory for the flexural waves, while the transfer matrix method is used to model reflection and transmission coefficients of a single plate. Experimental results are obtained by using an acoustic impedance tube. The difference b…

Absorption (acoustics)Materials scienceAcoustics and UltrasonicsPhysics::Instrumentation and DetectorsTransfer-matrix method (optics)Physics::Optics01 natural sciencesCondensed Matter::Disordered Systems and Neural Networks03 medical and health sciences0302 clinical medicineThermal conductivityArts and Humanities (miscellaneous)0103 physical sciencesReflection coefficientComposite material030223 otorhinolaryngology010301 acousticsComputingMilieux_MISCELLANEOUSMetamaterialAerogel[PHYS.MECA]Physics [physics]/Mechanics [physics][PHYS.MECA.ACOU]Physics [physics]/Mechanics [physics]/Acoustics [physics.class-ph]Condensed Matter::Soft Condensed MatterReflection (mathematics)[PHYS.MECA] Physics [physics]/Mechanics [physics]Acoustic impedance[PHYS.MECA.ACOU] Physics [physics]/Mechanics [physics]/Acoustics [physics.class-ph]
researchProduct

Absorption spectrum of the and electronic transitions of ReF6

1999

Abstract The absorption spectra of the near-infrared and ultraviolet bands of ReF6 have been recorded with a commercial spectrophotometer. The vibronic assignments previously published by different authors are critically revised. A non-perturbative method has been used to calculate the linear Jahn–Teller levels for the ν5 mode in the ground electronic state. Some new vibronic parameter values are derived. The ν5 linear Jahn–Teller parameter in the X G′ g electronic state is found to be D5=0.103(9). The ultraviolet absorption spectrum has enabled us to determine relatively accurate values of the crystal-field (10Dq) and spin-orbit (ζd) parameters.

Absorption spectroscopyRhenium hexafluoridemedicine.disease_causeAtomic and Molecular Physics and OpticsUltraviolet absorption spectrumAnalytical Chemistrychemistry.chemical_compoundchemistryAtomic electron transitionmedicineVibronic spectroscopyCondensed Matter::Strongly Correlated ElectronsAtomic physicsInstrumentationSpectroscopyUltravioletSpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
researchProduct

Design study for a 500 MeV positron beam at the Mainz Microtron MAMI

2022

A design study has been performed for a positron beam with an energy of 500 MeV to be realized at the applied physics area of the Mainz Microtron MAMI. Positrons will be created after pair conversion of bremsstrahlung, produced by the 855 MeV electron beam af MAMI in a tungsten converter target. From the two conceivable geometries (i) pair conversion in the bremsstrahlung converter target itself, and (ii) bremsstrahlung pair conversion in a separated lead foil, the former was considered in detail. Positrons will be energy selected within an outside open electron beam-line bending magnet, and bent back by an additional sector magnet. Magnetic focusing elements in between are designed to prep…

Accelerator Physics (physics.acc-ph)530 PhysicsPhysics::Instrumentation and DetectorsPhysics::Accelerator PhysicsFOS: Physical sciencesPhysics - Accelerator Physics530 PhysikNuclear ExperimentAtomic and Molecular Physics and Optics
researchProduct

New exotic beams from the SPIRAL 1 upgrade

2018

Since 2001, the SPIRAL 1 facility has been one of the pioneering facilities in ISOL techniques for reaccelerating radioactive ion beams: the fragmentation of the heavy ion beams of GANIL on graphite targets and subsequent ionization in the Nanogan ECR ion source has permitted to deliver beams of gaseous elements (He, N, O, F, Ne, Ar, Kr) to numerous experiments. Thanks to the CIME cyclotron, energies up to 20 AMeV could be obtained. In 2014, the facility was stopped to undertake a major upgrade, with the aim to extend the production capabilities of SPIRAL 1 to a number of new elements. This upgrade, which is presently under commissioning, consists in the integration of an ECR booster in the…

Accelerator Physics (physics.acc-ph)Nuclear and High Energy PhysicsNuclear engineering[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]tutkimuslaitteetCyclotronFOS: Physical scienceshiukkaskiihdyttimet[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]nucl-ex7. Clean energy01 natural sciencesIonlaw.inventionion sourceslawIonization0103 physical sciencesIon sourcesNuclear Physics - ExperimentNuclear Experiment (nucl-ex)radioactive ion beams010306 general physicsNuclear ExperimentInstrumentationRadioactive ion beamsphysics.acc-ph[PHYS]Physics [physics]Physics010308 nuclear & particles physicsAccelerators and Storage RingsIon sourceUpgradesäteilyfysiikkaBeamlinePhysics - Accelerator PhysicsAGATABeam (structure)
researchProduct

Fast photon detection for particle identification with COMPASS RICH-1

2006

Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates of several $10^6$ per channel in the central detector region, and a read-out system allowing for trigger rates of up to 100 kHz. To cope with these requirements, the photon detectors in the central region have been replaced with the detection system described in this paper. In the peripheral regions, the existing multi-wire proportional chambers with CsI photocathode are now read out via a new system employing APV pre-amplifiers and flash ADC chips. The ne…

Accelerator Physics (physics.acc-ph)Nuclear and High Energy PhysicsPhotomultiplierPhysics - Instrumentation and DetectorsPhysics::Instrumentation and DetectorsCherenkov detectorOther Fields of PhysicsFOS: Physical sciencesCOMPASS; RICH; Multi-anode PMT; Particle identificationCOMPASSParticle identificationPhotocathodelaw.inventionParticle identificationNuclear physicsOpticsMulti-anode PMTlawCompassCOMPASS; RICHInstrumentationRICHCherenkov radiationPhysicsbusiness.industryDetectorInstrumentation and Detectors (physics.ins-det)UpgradePhysics - Accelerator PhysicsHigh Energy Physics::Experimentbusiness
researchProduct

Vertical Beam Polarization at MAMI

2017

For the first time a vertically polarized electron beam has been used for physics experiments at MAMI in the energy range between 180 and 855 MeV. The beam-normal single-spin asymmetry $A_{\mathrm{n}}$, which is a direct probe of higher-order photon exchange beyond the first Born approximation, has been measured in the reaction $^{12}\mathrm C(\vec e,e')^{12}\mathrm C$. Vertical polarization orientation was necessary to measure this asymmetry with the existing experimental setup. In this paper we describe the procedure to orient the electron polarization vector vertically, and the concept of determining both its magnitude and orientation with the available setup. A sophisticated method has …

Accelerator Physics (physics.acc-ph)Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsPhotonmedia_common.quotation_subjectVertical polarization[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]FOS: Physical sciencesElectron acceleratorElectronMott polarimeter01 natural sciencesAsymmetrylaw.inventionOpticsMøller polarimeterlaw0103 physical sciencesCompton polarimeter[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det][ PHYS.PHYS.PHYS-ACC-PH ] Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Born approximation010306 general physicsNuclear Experiment[ PHYS.PHYS.PHYS-INS-DET ] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Instrumentationmedia_commonPhysicsWien filter010308 nuclear & particles physicsbusiness.industryParticle acceleratorPolarimeterInstrumentation and Detectors (physics.ins-det)Wien filterPolarization (waves)Electron accelerator ; Vertical polarization ; Wien filter ; Compton polarimeter ; Mott polarimeter ; Møller polarimeterPhysics - Accelerator Physicsbusiness
researchProduct

Transition-Edge Sensors for Particle Induced X-ray Emission Measurements

2013

In this paper we present a new measurement setup, where a transitionedge sensor detector array is used to detect X-rays in particle induced X-ray emission measurements with a 2 MeV proton beam. Transition-edge sensors offer orders of magnitude improvement in energy resolution compared to conventional silicon or germanium detectors, making it possible to recognize spectral lines in materials analysis that have previously been impossible to resolve, and to get chemical information from the elements. Our sensors are cooled to the operation temperature (65 mK) with a cryogen-free adiabatic demagnetization refrigerator, which houses a specially designed X-ray snout that has a vacuum tight window…

Accelerator Physics (physics.acc-ph)Physics - Instrumentation and DetectorsMaterials scienceProtonPhysics::Instrumentation and DetectorsOrders of magnitude (temperature)FOS: Physical scienceschemistry.chemical_elementGermaniumRadiationSpectral lineOpticsGeneral Materials Scienceparticle induced X-ray emission (PIXE)Emission spectrumbusiness.industryDetectorInstrumentation and Detectors (physics.ins-det)transition-edge sensorCondensed Matter PhysicsAtomic and Molecular Physics and OpticsFull width at half maximumchemistryPhysics - Accelerator PhysicsbusinessTESJournal of Low Temperature Physics
researchProduct

Design of a 10 GHz minimum-B quadrupole permanent magnet electron cyclotron resonance ion source

2020

This paper presents a simulation study of a permanent magnet electron cyclotron resonance ion source (ECRIS) with a minimum-B quadrupole magnetic field topology. The magnetic field is made to conform to conventional ECRIS with $B_\textrm{min}/B_\textrm{ECR}$ of 0.67 and a last closed magnetic isosurface of 1.86$B_\textrm{ECR}$ at 10 GHz. The distribution of magnetic field gradients parallel to the field, affecting the electron heating efficiency, cover a range from 0 to 13 T/m, being similar to conventional ECRIS. Therefore it is expected that the novel ion source produces warm electrons and high charge state ions in significant number. Single electron tracking simulations are used to estim…

Accelerator Physics (physics.acc-ph)PhysicsIon beam analysis010308 nuclear & particles physicsFOS: Physical sciencesElectron01 natural sciences7. Clean energyIon sourceElectron cyclotron resonance030218 nuclear medicine & medical imagingIon03 medical and health sciences0302 clinical medicineBeamlinePhysics::Plasma PhysicsMagnet0103 physical sciencesQuadrupolePhysics::Accelerator PhysicsPhysics - Accelerator PhysicsAtomic physicsInstrumentationMathematical PhysicsJournal of Instrumentation
researchProduct

Highly efficient isotope separation and ion implantation of  163Ho for the ECHo project

2019

Abstract The effective electron neutrino mass measurement in the framework of the ECHo experiment requires radiochemically pure 163 Ho, which is ion implanted into detector absorbers. To meet the project specifications in efficiency and purity, the entire process chain of ionization, isotope separation , and implantation of 163Ho was optimized. A new two-step resonant laser ionization scheme was established at the 30 kV magnetic mass separator RISIKO. For ionization and separation, an average efficiency of 69 ( 5 )  stat(4)sys% was achieved using intra-cavity frequency doubled Ti:sapphire lasers. The implantation of undesired 166 m Ho, which is present in trace amounts in the initial  163Ho…

Accelerator Physics (physics.acc-ph)PhysicsNuclear and High Energy PhysicsAtomic Physics (physics.atom-ph)Orders of magnitude (temperature)DetectorAnalytical chemistryFOS: Physical sciencesLaser01 natural sciencesPhysics - Atomic Physics010305 fluids & plasmasIsotope separationlaw.inventionIonIon implantationlawIonization0103 physical sciencesSapphirePhysics - Accelerator Physics010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Channeling experiments at planar diamond and silicon single crystals with electrons from the Mainz Microtron MAMI

2020

Line structures were observed for (110) planar channeling of electrons in a diamond single crystal even at a beam energy of 180 MeV . This observation motivated us to initiate dechanneling length measurements as function of the beam energy since the occupation of quantum states in the channeling potential is expected to enhance the dechanneling length. High energy loss signals, generated as a result of emission of a bremsstrahlung photon with about half the beam energy at channeling of 450 and 855 MeV electrons, were measured as function of the crystal thickness. The analysis required additional assumptions which were extracted from the numerical solution of the Fokker-Planck equation. Prel…

Accelerator Physics (physics.acc-ph)PhysicsSilicon010308 nuclear & particles physicsFOS: Physical sciencesDiamondchemistry.chemical_elementElectronengineering.material01 natural sciencesCrystalLength measurementchemistry0103 physical sciencesengineeringPhysics::Accelerator PhysicsPhysics - Accelerator PhysicsAtomic physics010306 general physicsInstrumentationMicrotronSingle crystalMathematical PhysicsBeam (structure)Journal of Instrumentation
researchProduct