Quantitative Determination of Renal 99mTc-MAG3 Clearance. A Comparison of Results Acquired Simultaneously in Whole Body Geometry and with a Gamma Cam…
1997
289 patients were simultaneously investigated with a partially shielded whole body counter (Oberhausen) and in camera technique to correlate the values of the MAG3-clearance. Good correlation was found for the often used times schedules of taking blood samples. Late blood samples increase high clearance values in both methods slighly. The shape of the ROI has no influence using camera technique. We conclude, that camera technique can replace the Oberhausen method with a partially shielded whole body counter.
Proof-of-principle measurements with a liquid-scintillator detector using wavelength-shifting optical modules
2018
Based on test-beam measurements, we study the response of a liquid-scintillator detector equipped with wavelength-shifting optical modules, that are proposed e.g. for the IceCube experiment and the SHiP experiment, and adiabatic light guides that are viewed either by a photomultiplier tube or by an array of silicon photomultipliers. We report on the efficiency, the time resolution and the detector response to different particle types and point out potential ways to improve the detector performance.
Design and implementation of the UFFO burst alert and trigger telescope
2012
The Ultra Fast Flash Observatory pathfinder (UFFO-p) is a telescope system designed for the detection of the prompt optical/UV photons from Gamma-Ray Bursts (GRBs), and it will be launched onboard the Lomonosov spacecraft in 2012. The UFFO-p consists of two instruments: the UFFO Burst Alert and Trigger telescope (UBAT) for the detection and location of GRBs, and the Slewing Mirror Telescope (SMT) for measurement of the UV/optical afterglow. The UBAT isa coded-mask aperture X-ray camera with a wide field of view (FOV) of 1.8 sr. The detector module consists of the YSO(Yttrium Oxyorthosilicate) scintillator crystal array, a grid of 36 multi-anode photomultipliers (MAPMTs), and analog and digi…
Angular resolution of an array of tracking-chamber detectors for use in high-energy gamma-ray astronomy
1992
We describe a method of analysis for the reconstruction of the arrival direction of a high-energy photon impacting on the top of the atmosphere by using the directions of the particles on the shower front as measured by a ground-based array of tracking chambers uniformly distributed on a square surface; as an example, an array with enclosed surface of (120×120) m2 has been considered. Estimates on the accuracy of reconstruction are given, after application of the method to computer-simulated shower directions as a function of the number of «smapling» detectors and of their accuracy in the measurement of the «local» shower direction.
The optical instrumentation of the ATLAS Tile Calorimeter
2013
The purpose of this Note is to describe the optical assembly procedure called here Optical Instrumentation and the quality tests conducted on the assembled units. Altogether, 65 Barrel (or LB) modules were constructed - including one spare - together with 129 Extended Barrel (EB) modules (including one spare). The LB modules were mechanically assembled at JINR (Dubna, Russia) and transported to CERN, where the optical instrumentation was performed with personnel contributed by several Institutes. The modules composing one of the two Extended Barrels (known as EBA) were mechanically assembled in the USA, and instrumented in two US locations (ANL, U. of Michigan), while the modules of the oth…
Measurement of radionuclide activities induced in target components of an IBA CYCLONE 18/9 by gamma-ray spectrometry with HPGe and LaBr3: Ce detector…
2014
Cyclotrons are used worldwide to produce radiopharmaceuticals by proton irradiation of a suitable target. The intense secondary neutron beam generated by proton interactions with the target induce high radionuclide activities in the target assembly parts that may result in an exposure to high dose levels of the operators during maintenance. The main goal of this work is to evaluate gamma-emitting radionuclide activities induced in Havar foils and titanium windows of a target assembly and carousel stripper forks of an IBA CYCLONE 18/9 cyclotron. The knowledge of radionuclide inventory for each component is required by many companies to assess risk for operators before waste handling and disp…
Ageing studies of TPB in noble gas detectors for dark matter and neutrinoless ββ decay searches
2017
Noble gases (Xe, Ar, Kr) are very attractive as detector media in Dark Matter search and neutrinoless double-beta decay experiments. However, the detection of their scintillation light (in the VUV spectral region) requires shifting the VUV light to visible light, where standard photosensors are more efficient. Tetraphenyl butadiene (TPB) is widely used as wavelength shifter, absorbing the VUV light and re-emitting in the blue region (~430nm). TPB is an organic molecule that may degrade due to exposure to environmental agents and also to ultraviolet light. In this work, we present TPB ageing studies due to exposure to VUV light, aiming at quantifying the reduction of the absolute fluorescenc…
Precision Lifetime Measurements Using LaBr3 Detectors With Stable and Radioactive Beams
2013
A range of high resolution gamma-ray spectroscopy measurements have been carried out using arrays which include a number of Cerium-doped Lanthanum-Tribromide (LrBr3 (Ce)) scintillation detectors used in conjunction with high-resolution hyper-pure germanium detectors. Examples of the spectral and temporal responses of such set-ups, using both standard point radioactive sources 152 Eu and 56 Co, and in-beam fusionevaporation reaction experiments for precision measurements of nuclear excited states in 34 P and 138 Ce are presented. The current and future use of such arrays at existing (EURICA at RIKEN) and future (NUSTAR at FAIR) secondary radioactive beam facilities for precision measurements…
The X-ray gas scintillation spectrometer experiment on the first spacelab flight
1985
The First Spacelab mission, launched on Space ShuttleFlight STS-9 in November 1983 carried a multidisciplinary payload which was intended to demonstrate that valuable scientific results can be achieved from such short duration missions. The payload complement included a spectrometer to undertake observations of the brighter cosmic X-ray sources. The primary scientific objectives of this experiment were the study of detailed spectral features in cosmic X-ray sources and their associated temporal variations over a wide energy range from about 2 up to 30 keV. The instrument based on the gas scintillation proportional counter had an effective area of some 180 cm2 with an energy resolution of ∼9…
Cosmic ray effect on the X-ray Trigger Telescope of UFFO/Lomonosov using YSO scintillation crystal array in space
2017
UFFO Burst Alert and Trigger telescope (UBAT) is the X-ray trigger telescope of UFFO/Lomonosov to localize X-ray source with coded mask method and X-ray detector. Its X-ray detector is made up of 36 8×8 pixels Yttrium OxyorthoSilicate (Y2SiO5:Ce, YSO) scintillation crystal arrays and 36 64-channel Multi-Anode PhotoMultiplier Tubes (MAPMTs) for space mission. Its effective detection area is 161cm2 and energy range is several keV to 150 keV. It was successfully launched in April 28, 2016. In several calibration run, we got several X-ray background data. We already knew X-ray background flux is 2-3 counts/cm2/sec in space. However our X-ray background data shows approximately 7-8 times higher …