Search results for "SCOPE"
showing 10 items of 2420 documents
In vivo endomicroscopy improves detection of Barrett’s esophagus–related neoplasia: a multicenter international randomized controlled trial
2013
Background Confocal laser endomicroscopy (CLE) enables in vivo microscopic imaging of the GI tract mucosa. However, there are limited data on endoscope-based CLE (eCLE) for imaging Barrett's esophagus (BE). Objective To compare high-definition white-light endoscopy (HDWLE) alone with random biopsy (RB) and HDWLE + eCLE and targeted biopsy (TB) for diagnosis of BE neoplasia. Design Multicenter, randomized, controlled trial. Setting Academic medical centers. Patients Adult patients with BE undergoing routine surveillance or referred for early neoplasia. Intervention Patients were randomized to HDWLE + RB (group 1) or HDWLE + eCLE + TB (group 2). Real-time diagnoses and management plans were r…
Detection of spontaneous echocardiographic contrast within the left atrium by transesophageal echocardiography: spontaneous echocardiographic contrast
1986
Transesophageal echocardiography was performed in 314 patients over a period of 24 months using a 3.5 MHz phased-array system fitted to the distal end of a conventional 12 mm endoscope. In 12 patients (2.6%) transesophageal echocardiography could not be performed because of adverse reaction to the gastroscopic procedure. Side effects were a transient A-V block in one patient and asthmatic attack in another. Mitral valve lesions were found in 99 of 314 patients. In 9 of these 99 patients (11%), including 1 patient with mitral valve stenosis and sinus rhythm, 2 with atrial fibrillation, 3 with disc, and 3 with porcine mitral prosthesis, spontaneous echocardiographic contrast was found within …
Investigation of the Effect of Duodenoscopy on Sphincter of Oddi Manometry
1991
To investigate whether endoscopy affects sphincter of Oddi (SO) manometry, three patients who had undergone previous cholecystectomy and had a T-tube in situ for drainage were studied. Manometry was performed using a perfused triple lumen manometry catheter (diameter 1.7 mm), which was advanced into the SO lumen through the T-tube. SO motility, baseline pressure, common bile duct pressure and duodenal pressure were monitored before and during endoscopy while the tip of the endoscope was in the mouth, esophagus (upper third, precardial), stomach and duodenum. Endoscopy and even a moderate insufflation of air necessary to pass the pylorus and inspect the papilla of Vater did not affect the pa…
Minilaparoscopy versus conventional laparoscopy in the diagnosis of hepatic diseases
2001
Minilaparoscopy (ML) is being used increasingly in the diagnosis of liver disease. This is a prospective study of the accuracy and safety of ML compared with conventional laparoscopy (CL) in the diagnostic workup of liver disease.One hundred four patients with suspected liver disease were randomized either to undergo CL (n = 50) or ML (n = 54). CL was performed with a standard Storz laparoscope (Ø 11 mm, Storz GmbH, Tuttlingen, Germany) according to accepted guidelines. For ML a 1.9-mm small-diameter optical telescope was used (Richard Wolf GmbH, Knittlingen, Germany). In all cases, an attempt was made to obtain a liver biopsy specimen.Laparoscopy could successfully be performed in 100 of 1…
Endoscopy in aneurysm surgery.
2011
BACKGROUND: Surgical clipping with complete occlusion of the aneurysm and preservation of parent, branching, and perforating vessels remains the most definitive treatment for intracranial aneurysms. OBJECTIVE: To evaluate the benefit of endoscopic application during microsurgical procedures in a retrospective study. METHODS: One hundred eighty aneurysms were microsurgically treated in 124 operations. Three different applications of endoscopic visualization were used, depending on the respective requirements: inspection before clipping, clipping under endoscopic view, and postclipping evaluation. RESULTS: Of 1380 aneurysms, 292 procedures were done with application of the endoscope. Of these…
Capsule Endoscopy versus Push Enteroscopy in Patients with Occult Gastrointestinal Bleeding
2003
Background Wireless capsule endoscopy is a new method enabling non-invasive diagnostic endoscopy of the entire small intestine. In this study we prospectively examined the diagnostic precision of capsule endoscopy compared with push enteroscopy in patients with occult gastrointestinal bleeding. Methods Between July 2001 and October 2002 we examined 48 patients with suspected disorders of the small intestine using capsule endoscopy. 33 patients with obscure bleeding (19 men, 14 women, mean age 58 +/- 23 years) were prospectively examined using capsule endoscopy and push enteroscopy. Results On average, the patients had been suffering from chronic gastrointestinal bleeding for 30 +/- 36 (1-12…
Bacteremia after diagnostic conventional laparoscopy and minilaparoscopy: a prospective study in 100 patients.
2006
Background/Goals: Diagnostic laparoscopy under sedoanalgesia is a valuable tool in the work-up of liver diseases and is helpful as a staging procedure. The rate of bacteremia caused by this procedure is unknown, in particular when performed as minilaparoscopy. Study: A 100 consecutive patients having undergone diagnostic laparoscopy carried out either conventionally (group I, n = 50) or as minilaparoscopy (group II, n - 50) were prospectively enrolled in this study. Blood cultures were drawn before and within 5 minutes after the procedure. Risk factors for bacteremia were evaluated. Results: Bacterial growth occurred in 4 blood cultures drawn immediately after laparoscopy. No patient develo…
Mono-stereo-autostereo: the evolution of 3-dimensional neurosurgical planning.
2012
BACKGROUND: In the past decade, surgery planning has changed significantly. The main reason is the improvements in computer graphical rendering power and display technology, which turned the plain graphics of the mid-1990s into interactive stereoscopic objects. OBJECTIVE: To report our experiences with 2 virtual reality systems used for planning neurosurgical operations. METHODS: A series of 208 operations were planned with the Dextroscope (Bracco AMT, Singapore) requiring the use of liquid crystal display shutter glasses. The participating neurosurgeons answered a questionnaire after the planning procedure and postoperatively. In a second prospective series of 33 patients, we used an autos…
Influence of plasma cleaning procedure on the interaction between soft tissue and abutments: a randomized controlled histologic study
2016
Introduction Plasma application can lead to an improved adhesion between soft tissue and abutments and promotes cell spreading. Objective A triple-blinded randomized controlled clinical trial was performed to in vivo test the effect of cleaning abutment titanium surfaces with plasma of argon on cell adhesion and collagen fiber orientation at an early healing time. Material and methods Thirty healthy patients with 30 submerged implants, at the second surgery, randomly received either a specially designed abutment with no additional treatment (as they come from industry; control group, G1) or cleaned by plasma of argon (test group, G2). Two weeks thereafter, a small biopsy including abutment …
Performance of the compensation comparison method for retinal straylight measurement: effect of patient's age on repeatability
2008
Aim: The assessment of repeatability and reproducibility of retinal straylight measurements with the C-Quant straylight meter (Oculus AG, Germany) and the effect of patient’s age on the instrument performance are tested with a series of experiments. Methods: First, 20 eyes from 20 subjects (mean age 26.9 (SD 2.7) years, mean refractive error −1.34 (2.72) D) were examined with the C-Quant straylightmeter, taking 10 consecutive readings. Five subjects were also examined on five consecutive days to assess reproducibility. Additionally, repeated measures of straylight from 84 subjects of ages ranging from 19 to 86 years (mean (SD): 42.4 (24.0) years) were retrospectively analysed to assess the …