Search results for "SCOPE"
showing 10 items of 2420 documents
Piezoelectric Rainfall Energy Harvester Performance by an Advanced Arduino-Based Measuring System
2018
This paper presents the performances of rainfall energy harvesting through the use of a piezoelectric transducer and an Arduino-based measuring system. Different studies agree on the possibility of generating electricity from rainfall, but to date, a study on measuring the quantity of energy produced during rainfall is still missing. The present study begins with results obtained from laboratory researchers using piezoelectric transducers and oscilloscopes, finalized to measure the energy produced from a single raindrop, and concludes with an ad hoc Arduino-based measuring system, aimed to measure the actual amount of electrical energy produced by a piezoelectric transducer that is exposed …
The Use of Accelerometers and Gyroscopes to Estimate Hip and Knee Angles on Gait Analysis
2014
In this paper the performance of a sensor system, which has been developed to estimate hip and knee angles and the beginning of the gait phase, have been investigated. The sensor system consists of accelerometers and gyroscopes. A new algorithm was developed in order to avoid the error accumulation due to the gyroscopes drift and vibrations due to the ground contact at the beginning of the stance phase. The proposed algorithm have been tested and compared to some existing algorithms on over-ground walking trials with a commercial device for assisted gait. The results have shown the good accuracy of the angles estimation, also in high angle rate movement.
A Multi-Position Calibration Method for Consumer-Grade Accelerometers, Gyroscopes, and Magnetometers to Field Conditions
2017
This paper presents a calibration method for consumer-grade accelerometers, gyroscopes, and magnetometers. Considering the calibration of consumer-grade sensors, it is essential that no specialized equipment is required to create reference signals. In addition, the less is required from the reference signals, the more suitable the method is on the field. In the proposed method, the novelty in the calibration of the gyroscopes lies in the exploitation of only the known net rotations between the positions in a multi-position calibration. For accelerometers and magnetometers, the innovation is that the direction of reference signals, the gravity and the magnetic field of the Earth, are estimat…
On Detection of Yaw and Roll Angle Information for Vehicle Oblique Crash using Hough Transform
2014
When performing vehicle crash tests, it is common to capture high frame rate video (HFR) to observe the vehicle motion during the impact. Such videos contain a lot of information, especially when it comes to geometric data. The yaw and roll angles from the HFR video is detected by using the Hough Transform and Matlab's Image processing Toolbox. The measured Yaw angle from the HFR video are compared with real life test data captured with a gyroscopic device inside the vehicle during the oblique vehicle impact.
The Challenge of a Place-and Network-based Approach to Development in Italian Regions
2016
Abstract This paper investigates the role of research networks inside local development processes to increase the competitiveness of underdeveloped territories. This paper, within the scope of local development theory, aims to describe the state of the art on the regional research systems resulting largely from programs co-financed between 2000 and 2013, with which the various regions are preparing to engage in programming for the period 2014-2020. The extent of consistency between the objectives of sectorial specialization set by policies previously or currently implemented and those in the planning phase (S3) is assessed, as is their connection with existing territorial specializations at…
Endoscopic interventions in the small bowel using double balloon enteroscopy: feasibility and limitations.
2007
Double-balloon enteroscopy (DBE) is a new endoscopic tool that not only allows diagnostic workup of small bowel diseases, but also makes it possible to carry out therapeutic interventions. However, for a variety of reasons, endoscopic therapy appears to be more difficult to carry out deep in the small bowel than in the upper or lower gastrointestinal tract.The purpose of this study was to evaluate the acute technical success and acute complication rate of DBE.Between June 2003 and July 2006, 353 patients (152 women, 201 men; mean age 60.3 +/- 17.1 yr) with suspected or known small bowel disease underwent 635 consecutive DBE procedures. The majority of the patients were suffering from midgas…
Push-and-pull enteroscopy using a single-balloon technique for difficult colonoscopy.
2006
Background and study aims Several factors predict difficult or incomplete colonoscopy with a standard colonoscope, including female gender, low body mass index, extensive diverticulosis, and prior pelvic surgery. Patients and methods A push-and-pull enteroscopy device and a single-balloon technique was used in 14 patients (six men, eight women; mean age 62 +/- 15 years) after failure of ileocolonoscopy or endoscopic therapy using either a standard or a pediatric colonoscope. The original ileocolonoscopy had been performed to investigate colon polyps (n = 6), an obscure inflammatory process in the ileocecal region (n = 6), or iron deficiency anemia with a positive fecal occult stool test (n …
Prospective comparison of push enteroscopy and push-and-pull enteroscopy in patients with suspected small-bowel bleeding.
2006
BACKGROUND The management of patients with suspected mid-gastrointestinal bleeding has in the past been AND AIMS: difficult, as push enteroscopy (PE) only allows limited endoscopic access for diagnosis and treatment. Recently published uncontrolled data on push-and-pull enteroscopy (PPE) using the double-balloon technique suggest that this new method has a high diagnostic yield and therapeutic efficacy. A prospective controlled study was therefore carried out to compare PPE with PE as the common nonsurgical gold standard method. METHODS: The diagnostic yield, complications, and various examination parameters were compared in 52 consecutive patients with suspected mid-gastrointestinal bleedi…
Transvalvular enteroscopy using a mother-baby endoscope system: a new approach to the distal ileum.
1997
In the past decade various endoscopes have been developed to examine the small bowel, with two principal procedures established: sonde-type enteroscopy and push-type enteroscopy. The main indication is gastrointestinal bleeding of obscure origin. Push-type enteroscopy has proved itselfto be useful for the investigation ofdiseases of the small intestine. 1 The mean instrumental insertion length published by different working groups varied between 50 and 90 cm past the ligament of Trei tzfl 2 The small bowel examination area is limited to the jejunum. The alternative method is sonde-type enteroscopy that allows an insertion length of 140 (30 to 200) cm. 3, 4 Disadvantages of this type of ente…