Search results for "SEPARATOR"
showing 10 items of 128 documents
A new differentially pumped plunger device to measure excited-state lifetimes in proton emitting nuclei
2013
Abstract A new plunger device has been designed and built to measure the lifetimes of unbound states in exotic nuclei beyond the proton drip-line. The device has been designed to work in both vacuum and dilute-gas environments made possible through the introduction of a low-voltage stepping motor. DPUNS will be used in conjunction with the gas-filled separator RITU and the vacuum separator MARA at the accelerator laboratory of the University of Jyvaskyla, Finland, to measure the lifetimes of excited states with low population cross-sections. This is achieved by eliminating the need for a carbon foil to isolate the helium gas of RITU from the beam line thus reducing the background from beam-…
On-line implementation and first operation of the Laser Ion Source and Trap at ISOLDE/CERN
2015
13 pags.; 12 figs.; 2 tab.; Open Access funded by CERN
The MARA-LEB ion transport system
2020
Abstract A low-energy branch is under development for the MARA vacuum-mode recoil separator at the Accelerator Laboratory of the University of Jyvaskyla. This development will allow for the study of proton-rich nuclei through laser ionisation spectroscopy and mass measurements. After stopping and extraction from a buffer gas cell, the ions of interest will be accelerated and transported to dedicated experimental setups by an ion transport system consisting of several focusing, accelerating and mass-separating elements. This article presents the current design and simulations for the ion transport.
Spectroscopic Tools Applied to Flerovium Decay Chains
2020
Abstract An upgraded TASISpec setup, with the addition of a veto DSSD and the new Compex detector-germanium array, has been employed with the gas-filled recoil separator TASCA at the GSI Helmholtzzentrum für Schwerionenforschung Darmstadt, to study flerovium (element 114) decay chains. The detector upgrades along with development of new analytical techniques have improved the sensitivity of the TASISpec setup for measuring α-photon coincidences. These improvements have been assessed with test reactions. The reaction 48Ca+206,207Pb was used for verification of experimental parameters such as transmission to implantation DSSD and target-segment to α-decay correlations. The reaction 48Ca+ nat …
The identification and confirmation of isomeric states in 254Rf and 255Rf through conversion electron detection
2020
Abstract The neutron-deficient isotopes 254,255Rf were produced in the fusion-evaporation reaction 50Ti + 206Pb at the gas-filled recoil separator TASCA. Decay properties of these nuclei were investigated by applying fast digital electronics. A search for isomeric states in both isotopes was performed by using the accompanying conversion electron emissions. Isomeric states with half-lives of 4(1) μs and >30 μs were measured for 254Rf and 255Rf, respectively, which confirm the findings at different separators. The present experimental results demonstrate the great potential of fast digital electronics for measurements of isomeric states in the heaviest nuclei, which are only producible in sm…
Status report of the Jyvaskyla ion guide isotope separator on-line facility
1997
The ion guide isotope separator facility IGISOL of the University of Jyvaskyla has been moved to the new K-130 heavy ion cyclotron laboratory. The totally reconstructed facility is described in detail. The primary beams and targets, helium pumping, separator beam line construction and separator beam diagnostics are discussed. The spectroscopy stations are introduced with illustrative examples from the research program, including beta-delayed proton and neutron spectroscopy, gamma-ray spectroscopy with and without arrays, conversion electron spectroscopy, collinear laser spectroscopy and nuclear level lifetime spectroscopy.
Terbium Medical Radioisotope Production: Laser Resonance Ionization Scheme Development
2021
Terbium (Tb) is a promising element for the theranostic approach in nuclear medicine. The new CERN-MEDICIS facility aims for production of its medical radioisotopes to support related R&D projects in biomedicine. The use of laser resonance ionization is essential to provide radioisotopic yields of highest quantity and quality, specifically regarding purity. This paper presents the results of preparation and characterization of a suitable two-step laser resonance ionization process for Tb. By resonance excitation via an auto-ionizing level, the high ionization efficiency of 53% was achieved. To simulate realistic production conditions for Tb radioisotopes, the influence of a surplus of Gd at…
The Inchworm as a precision translator in a high magnetic field and UHV environment
1989
Abstract A new set-up has been designed and tested for on-line, high-precision mass measurements of short-lived radioactive isotopes via a determination of the ion cyclotron resonance. Ions delivered by the on-line isotope separator ISOLDE at CERN/Geneva are stored in a Penning trap installed in a superconducting solenoid. Due to severe space limitations in the bore of the solenoid, it is impossible to use conventional mechanical feedthroughs for the necessary manipulations inside the uhv chamber. Instead, a number of Inchworms, a high-precision positioning device based on the piezo-electric effect are employed. This publication reports on the first application of this device in a uhv envir…
The SAGE spectrometer: A tool for combined in-beam gamma-ray and conversion electron spectroscopy
2010
International audience; The sage spectrometer allows simultaneous in-beam -ray and internal conversion electron measurements, by combining a germanium detector array with a highly segmented silicon detector and an electron transport system. sage is coupled with the ritu gas- lled recoil separator and the great focal-plane spectrometer for recoil-decay tagging studies. Digital electronics are used both for the ray and the electron parts of the spectrometer. sage was commissioned in the Accelerator Laboratory of the University of Jyvaskyla in the beginning of 2010.
TASISpec—A highly efficient multi-coincidence spectrometer for nuclear structure investigations of the heaviest nuclei
2010
TASISpec (TASCA in Small Image mode Spectroscopy) combines composite Ge- and Si-detectors for a new detector setup aimed towards multi-coincidence gamma -ray, X-ray, conversion electron, fission fragment, and a-particle spectroscopy of the heaviest nuclei. It exploits the TASCA separator's unique small image focal mode, i.e. the fact that evaporation residues produced in fusion-evaporation reactions can be focused into an area of less than 3 cm in diameter. This provides the possibility to pack detectors in very close geometry, resulting in an unprecedented detection efficiency of radioactive decays in prompt and delayed coincidence with implanted nuclei. Crown Copyright (C) 2010 Publis…