Search results for "SEPARATOR"
showing 10 items of 128 documents
Spectroscopic Tools Applied to Flerovium Decay Chains
2020
Abstract An upgraded TASISpec setup, with the addition of a veto DSSD and the new Compex detector-germanium array, has been employed with the gas-filled recoil separator TASCA at the GSI Helmholtzzentrum für Schwerionenforschung Darmstadt, to study flerovium (element 114) decay chains. The detector upgrades along with development of new analytical techniques have improved the sensitivity of the TASISpec setup for measuring α-photon coincidences. These improvements have been assessed with test reactions. The reaction 48Ca+206,207Pb was used for verification of experimental parameters such as transmission to implantation DSSD and target-segment to α-decay correlations. The reaction 48Ca+ nat …
Laser spectroscopy of radioactive Ti, Zr and Hf isotopes and isomers at the JYFL laser-IGISOL facility
2003
Abstract The recent progress at the laser-ion guide isotope separator on-line facility, JYFL, is presented. At the facility new techniques for studying short-lived radioisotopes by laser spectroscopy have been developed and applied to the study of isotopes in refractory metal elements. In particular, recent results on the spectroscopy of cooled ion beams of radioactive Ti, Zr and Hf isotopes are discussed.
Investigation of LaBr3(Ce) detectors at the RITU focal plane
2015
The aims of this master thesis were to determine the absolute detection efficiency of the LaBr3(Ce) detectors installed at the RITU focal plane, to study the effect of planar Ge-detector on the LaBr3(Ce) efficiency and to investigate the possibility of half-life measurements with the detectors in a coincidence setup having distributed recoil ions produced by the RITU separator. Time spectra were collected by moving a point radioactive source from one edge of the implantation detector to the other to imitate the ion distribution from the RITU separator. Simulations have been exploited to explore the time spectra obtained from various ion distribution shapes and for different half-lives. A po…
The Inchworm as a precision translator in a high magnetic field and UHV environment
1989
Abstract A new set-up has been designed and tested for on-line, high-precision mass measurements of short-lived radioactive isotopes via a determination of the ion cyclotron resonance. Ions delivered by the on-line isotope separator ISOLDE at CERN/Geneva are stored in a Penning trap installed in a superconducting solenoid. Due to severe space limitations in the bore of the solenoid, it is impossible to use conventional mechanical feedthroughs for the necessary manipulations inside the uhv chamber. Instead, a number of Inchworms, a high-precision positioning device based on the piezo-electric effect are employed. This publication reports on the first application of this device in a uhv envir…
On-line implementation and first operation of the Laser Ion Source and Trap at ISOLDE/CERN
2015
13 pags.; 12 figs.; 2 tab.; Open Access funded by CERN
Multicommutation cold vapour atomic fluorescence determination of Hg in water.
2002
Abstract A multicommutation-based method has been developed for the on-line direct atomic fluorescence spectrometric (AFS) determination of Hg in waters without any previous sample treatment. The performance of the proposed procedure has been compared with that of a conventional AFS system based on continuous mode measurements. In short, the use of multicommutation, together with a reduction of the size of the liquid–gas phase separator, provides an increase of the laboratory productivity by improving the sample throughput by a factor of 3.6 and strongly reduces the sample consumed by a factor of 6 and reagent consumed by a factor of 8.4. The waste generation is reduced by a factor of 2.4 a…
Behavior Modification of Nanostructured PbO2 Electrodes in Lead Acid Batteries Changing Electrolyte Concentration and Separator
2019
Currently, lead acid battery is extensively investigated owing to its prevalent use as a startinglighting and ignition device. An essential role for electrochemical reactions is played by the surface area available for conversion reactions and a possible approach is the use of nanostructured electrodes. In this work, lead dioxide nanostructured electrodes were tested in order to investigate the dependence of the charge and discharge behaviour on some parameters such as electrolyte concentration, and a new type of thin separator. In this last case, it is possible to reduce the size of the cell by using a very thin separator comparable to the nanostructured electrode thickness. Besides, a low…
High-performance of PbO2 nanowire electrodes for lead-acid battery
2014
Abstract PbO2 nanowires were obtained by template electrodeposition in polycarbonate membranes and tested as positive electrode for lead-acid battery. Nanowires were grown on the same material acting as current collector that was electrodeposited too. The nanostructured electrodes were assembled in a zero-gap configuration using commercial negative plate and separator. Cell performance was tested by galvanostatic charge/discharge cycles in a 5 M H2SO4 aqueous electrolyte. PbO2 nanostructured electrodes were able to deliver at 1C rate an almost constant capacity of about 190 mAh g−1 (85% of active material utilization), close to the theoretical value (224 mAh g−1). The nanowire array provide…
Reduction of oxygen to H2O2 at carbon felt cathode in undivided cells. Effect of the ratio between the anode and the cathode surfaces and of other op…
2019
Abstract In the last years, the electrochemical conversion of oxygen to hydrogen peroxide at carbon felt has been largely studied in order to define a new route for the production of H2O2 and to optimize the electro-Fenton process, which is based on the cathodic generation of H2O2. In particular, many studies regarding electro-Fenton process were carried out in undivided cells in order to avoid the costs of the separator and to reduce the cell potentials. Hence, in order to optimize the cathodic conversion of oxygen to H2O2 in undivided cells, the effect of many parameters linked to the anodic process were here evaluated. In particular, it was demonstrated that the performances of the proce…
Efficiency of an on-line isotope separator system employing cooled and NaCl-loaded He-jet methods
1976
Abstract A pure helium-jet at liquid nitrogen temperature coupled to a Nielsen type ion source, and a NaCl-loaded helium-jet coupled to a hollow-cathode ion source have been investigated as means to connect a cyclotron target chamber on-line to a mass separator. Technical details and performances of some critical parts of the system are described. Total separation efficiencies measured under various experimental conditions for several nuclides vary between 0.01 and 1.0%.