Search results for "SINADR"
showing 4 items of 4 documents
Difference temperature-to-time electronic interface based on a thermistor-to-generalized impedance converter
2010
Abstract In this work a difference temperature-to-time converter is shown using two thermistors working in a DC generalized impedance converter. Voltage drop in one of the thermistors depends on the temperature difference between them. This voltage is compared with a time varying exponential reference voltage obtaining a time interval at the output circuit with good linear dependence with respect to the input temperature difference. Experimental results are obtained showing a new generalized impedance converter application. The implemented circuit was characterized by a repeatability of 1.0%, a reproducibility of 4.5% and a relative accuracy of 1.3%.
High-Efficiency Regulation Method for a Zero-Current and Zero-Voltage Current-Fed Push–Pull Converter
2011
A new high-efficiency regulation method for a zero-current and zero-voltage current-fed push-pull converter is presented. The method proposed is based on the use of a controlled transformer as a post-regulator, which adds or subtracts an additional voltage to the output filter of the converter. An auxiliary regulator, which only handles a percentage of the output power, controls this transformer, and therefore, results in much higher efficiency than a normal preregulator would have. The novelty of the presented converter is that regulation is achieved without affecting the zero-voltage and zero-current switching in any working conditions. Small- and large-signal models of the converter have…
A topology for multiple generation system with doubly fed induction machines and indirect matrix converter.
2008
In this paper, a new topology for a grid connected generation system based on two double fed induction generators is presented The scheme uses an indirect matrix converter consisting on an input rectifier, a three-to-two matrix converter which provides a DC voltage, and two voltage fed output converters. The input converter is connected to the grid and each of the output converters is connected to the rotor of the corresponding machine. The rotor currents of each generator are vector controlled and unity power factor operation at the indirect matrix converter input is considered. The duty cycles for the input converter are chosen in order to obtain maximum DC link voltage. The duty cycles f…
Dynamic modelling of a quadratic DC/DC single-switch boost converter
2017
This manuscript proposes the analysis of a Quadratic Boost Converter (QBC) transformer-less single switch typology. The state space average dynamic model and a constrained state space average model taking into account the mono-directional components of the converter (diodes, switches) have been analyzed. The static gain expression taking into consideration the parasitic elements of the converter and the small-signal transfer function of the QBC typology under study has been obtained. A sensitivity analysis has shown a high variation of the gain versus duty-cycle and of the derivative gain versus parasitic parameters of the converter in the range of the duty-cycle from 0.6 to 0.8 which is ra…