Search results for "STANDARD"
showing 10 items of 3299 documents
Comparison of CT and magnetic resonance mDIXON-Quant sequence in the diagnosis of mild hepatic steatosis
2018
Objective: To determine the diagnostic performance of CT in the assessment of mild hepatic steatosis by comparison with MR mDIXON-Quant as a reference standard, and to explore their clinical applications. Methods: In this prospective study 169 volunteers were included. Each subject underwent CT and MR mDIX-ON-Quant examinations. Hepatic steatosis evaluations were performed via liver attenuation alone (CT L), liver to spleen attenuation ratio (CT L/S), difference between liver and spleen attenuation (CT L-S), and MR mDIX-ON-Quant imaging. The effectiveness of CT L, CT L/S, and CT L-S in diagnosing hepatic steatosis severity of ≥5%, ≥10%, and ≥15% was compared, using mDIX-ON-Quant results as …
Vitamin D levels and IL28B polymorphisms are related to rapid virological response to standard of care in genotype 1 chronic hepatitis C.
2011
Background Genotype 1 (G1) chronic hepatitis C (CHC) patients achieving a rapid virological response (RVR) on pegylated interferon (PEG-IFN) plus ribavirin have a high chance of sustained virological response (SVR), influenced by IL28B status, viral load, fibrosis and insulin resistance. We assessed whether 25-hydroxyvitamin D (25[OH]D) serum levels are linked to RVR and can be used together with IL28B to construct a pretreatment model to predict RVR. Methods A total of 117 consecutive patients with G1 CHC were evaluated by biopsy and anthropometric and metabolic measurements. 25(OH)D serum levels were measured by HPLC. IL28B rs12979860 and rs8099917 polymorphisms were also evaluated. All p…
Impact of crestal and subcrestal implant placement in peri-implant bone: a prospective comparative study
2015
Background To assess the influence of the crestal or subcrestal placement of implants upon peri-implant bone loss over 12 months of follow-up. Material and Methods Twenty-six patients with a single hopeless tooth were recruited in the Oral Surgery Unit (Valencia University, Valencia, Spain). The patients were randomized into two treatment groups: group A (implants placed at crestal level) or group B (implants placed at subcrestal level). Control visits were conducted by a trained clinician at the time of implant placement and 12 months after loading. A previously established standard protocol was used to compile general data on all patients (sex and age, implant length and diameter, and bru…
Evidence for a white matter lesion size threshold to support the diagnosis of relapsing remitting multiple sclerosis
2018
Abstract Background The number of white matter lesions (WML) in brain MRI is the most established paraclinical tool to support the diagnosis of multiple sclerosis (MS) and to monitor its course. Diagnostic criteria have stipulated a minimum detectable diameter of 3 mm per WML, although this threshold is not evidence-based. We aimed to provide a rationale for a WML size threshold for three-dimensional MRI sequences at 3 T by comparing patients with relapsing-remitting MS (RRMS) to control subjects (CS). Methods We analyzed MR images from two cohorts, obtained at scanners from two different vendors, each comprising patients with RRMS and CS. Both cohorts were examined with FLAIR and T1w seque…
Quantifying coordination and coordination variability in backward versus forward running: Implications for control of motion
2015
The aims of this study were to compare coordination and coordination variability in backward and forward running and to investigate the effects of speed on coordination variability in both backward and forward running. Fifteen healthy male participants took part in this study to run forwards and backwards on a treadmill at 80%, 100% and 120% of their preferred running speeds. The coordinate data of passive reflective markers attached to body segments were recorded using motion capture systems. Coordination of shank-foot and thigh-shank couplings in sagittal plane was quantified using the continuous relative phase method. Coordination variability was calculated as the standard deviation of a…
Assessment of Heart Rate Variability Thresholds from Incremental Treadmill Tests in Five Cross-Country Skiing Techniques
2016
The assessment of heart rate variability (HRV) thresholds (HRVTs) as an alternative of Ventilatory thresholds (VTs) is a relatively new approach with increasing popularity which has not been conducted in cross-country (XC) skiing yet. The main purpose of the present study was to assess HRVTs in the five main XC skiing-related techniques, double poling (DP), diagonal striding (DS), Nordic walking (NW), V1 skating (V1), and V2 skating (V2).Ten competitive skiers completed these incremental treadmill tests until exhaustion with a minimum of one to two recovery days in between each test. Ventilatory gases, HRV and poling frequencies were measured. The first HRV threshold (HRVT1) was assessed us…
Multichannel functional testing in normal subjects, glaucoma suspects, and glaucoma patients
2012
Purpose.: To evaluate visual function with a novel multichannel functional test named the ATD Multichannel Functional Test. Methods.: This multicenter study had a prospective and cross-sectional design. A total of 186 eyes were included: 42 with glaucoma, 14 glaucoma suspects due to optic nerve characteristics, 25 ocular hypertensives, and 105 normal eyes. All patients performed standard visual fields (Humphrey 24-2) and ATD with eight stimuli configurations: four achromatic (A), two red-green (T), and two blue-yellow (D). To derive main outcome measures, mean sensitivity, mean defect (MD), and pattern standard deviation (PSD) were calculated and compared among groups and types of stimuli w…
Unexplained Elevated Serum Pancreatic Enzymes: A Reason to Suspect Celiac Disease
2006
BACKGROUND & AIMS: The frequency of elevated serum pancreatic enzymes in patients with celiac disease (CD) is unknown. The aim of this study was to evaluate the serum levels of pancreatic enzymes in CD patients. METHODS: Serum pancreatic isoamylase and lipase levels were assayed in 90 adult and 112 pediatric consecutive CD patients at diagnosis and after 12 months of gluten-free diet (GFD). Serum elastase and trypsin levels were assayed in a subgroup of adult CD patients. Pancreatic ultrasonography was also performed. RESULTS: Twenty-six adult (29%) and 29 pediatric (26%) CD patients exhibited elevated values of serum pancreatic amylase and/or lipase; trypsin was elevated in 69% and elastas…
Solid bone tumors of the spine: Diagnostic performance of apparent diffusion coefficient measured using diffusion-weighted MRI using histology as a r…
2017
Purpose To assess the diagnostic performance of mean apparent diffusion coefficient (mADC) in differentiating benign from malignant bone spine tumors, using histology as a reference standard. Conventional magnetic resonance imaging (MRI) sequences have good reliability in evaluating spinal bone tumors, although some features of benign and malignant cancers may overlap, making the differential diagnosis challenging. Materials and Methods In all, 116 patients (62 males, 54 females; mean age 59.5 ± 14.1) with biopsy-proven spinal bone tumors were studied. Field strength/sequences: 1.5T MR system; T1-weighted turbo spin-echo (repetition time / echo time [TR/TE], 500/13 msec; number of excitatio…
Reliability of different models to assess heart rate recovery after submaximal bicycle exercise.
2011
Abstract Objectives : Different models to assess HR recovery have been developed but knowledge of their reliability is poor at different submaximal exercise intensities and recovery durations. Our aim was to determine the reliability of HR recovery after a test on a cycle ergometer. Design : Twenty-one healthy individuals performed a submaximal exercise at 65% and 80% HR max followed by passive recovery. The exercise was repeated (retest) within 2 weeks to assess reliability. Method : HR recovery was assessed by 8 models, based on monoexponential kinetics or absolute recovery (recovered HR at fix time points). Intraclass correlation coefficient (ICC) and standard error of measurement (SEM, …