Search results for "STORAGE"
showing 10 items of 1239 documents
A new sample of large angular size radio galaxies II. The optical data
2001
We constructed and presented in the first paper of this series a new sample of 84 large angular size radio galaxies by selecting from the NRAO VLA Sky Survey objects with angular size > 4', declination above +60 degrees and total flux density at 1.4 GHz > 100 mJy. In this paper we present optical spectra and images of those galaxies associated with the radio emission for which no redshift was known prior to our observations. Optical counterparts have been identified for all (but one) members of the sample. After our observations, a reliable spectroscopic redshift is available for 67 objects (80%) from the sample. This paper, second of a series of three, contributes to increase the num…
First observation of trapped high-field seeking ultracold neutron spin states
2011
Ultracold neutrons were stored in a volume, using a magnetic dipole field shutter. Radial confinement was provided by material walls. Low-field seeking neutrons were axially confined above the magnetic field. High-field seeking neutrons are trapped inside the magnetic field. They can systematically shift the measured neutron lifetime to lower values in experiments with magnetic confinement. ISSN:0370-2693 ISSN:0031-9163 ISSN:1873-2445
Measurement of isotope shift and hyperfine splitting of190, 191, 193, 197Pb isotopes by collinear laser spectroscopy
1991
We report here on the measurement of isotope shift and hyperfine splitting of190, 191, 193, 197Pb for the 723 nm atomic optical transition. Detailed analysis of the optical data has been done by combining them with the available muonic and electronicx-ray isotope shift data. The magnetic dipole moments and the electric quadrupole moments of the odd isotopes have been extracted from the hyperfine coupling constants of the atomic states involved in the optical transition used.
Toward a New Test of the Relativistic Time Dilation Factor by Laser Spectroscopy of Fast Ions in a Storage Ring
2003
The frequency measurement of Doppler-shifted optical lines of ions circulating in a storage ring at high speed permits a sensitive test of the relativistic Doppler-formula and, hence, the time dilation factor γSR of special relativity. Previous measurements at the storage ring TSR with 7Li+ at v = 0.065c gave a new, improved limit, but were hampered by the large observed linewidth, exceeding the natural width 15-fold. Recently we have identified the broadening to be caused by velocity-changing processes in the storage ring. Saturation spectroscopy has proven to be largely immune against these effects and has yielded linewidths only a few MHz larger than the natural one. This is the major in…
Measurement of polarization observables in elastic and inelastic electron-deuteron scattering at the VEPP-3 storage ring.
2001
Measurement of the transverse Doppler shift using a stored relativistic7Li+ ion beam
1992
We have performed for the first time precision spectroscopy on a coasting fast7Li+ ion beam in a storage ring. The ion beam moving with 6.4% speed of light was first electron cooled and then merged with two counterpropagating laser beams acting on two different hyperfine transitions sharing a common upper level (λ-system). One laser was frequency locked to thea 3 127J2 hfs frequency component established as a secondary frequency standard at 514 nm. The second laser was tuned over theλ-resonance, which was recorded relative to127J2 hfs components. This experiment is sensitive to the time dilation in fast moving frames and will lead to new limits for the verification of special relatively. Th…
Precision measurement of two iodine lines at 585 nm and 549 nm
1993
The transition frequencies of thei-component of the R(99)15-1 and thew-component of the R(85)26-0 transition in the B-X system of molecular127I2 have been determined with an overall relative standard uncertainty of 1.3 · 10−10. For this purpose a commercial linear dye laser has been modified and stabilized to the corresponding iodine line. This dye laser serves as a transportable frequency standard which is compared with the wavelength standards of the PTB. The evaluation of an experiment for testing special relativity at the test storage ring (TSR) in Heidelberg is based on the precision of the reported interferometric wavelength comparison.
A linear radiofrequency quadrupole ion trap for the cooling and bunching of radioactive ion beams
2000
A linear radiofrequency quadrupole ion guide and beam buncher has been installed at the ISOLTRAP mass spectrometry experiment at the ISOLDE facility at CERN. The apparatus is being used as a beam cooling, accumulation, and bunching system. It operates with a buffer gas that cools the injected ions and converts the quasicontinuous 60- keV beam from the ISOLDE facility to 2.5-keV beam pulses with improved normalized transverse emittance. Recent measurements suggest a capture efficiency of the ion guide of up to 40% and a cooling and bunching efficiency of at least 12% which is expected to still be increased. The improved ISOLTRAP setup has so far been used very successfully in three on-line e…
Test of special relativity in an ion storage ring
1996
An accurate measurement of the Doppler effect in collinear laser spectroscopy has been performed at the TSR storage ring with electron cooled7Li+ ions atΒ=0.064. This experiment is a sensitive test of theγ=(1−Β2)−1/2 factor(Β=v/c) in the special theory of relativity. The Doppler shifted frequencies of the moving7Li+ ions are compared with calibrated molecular lines at rest. The frequencies at rest for the7Li+ ions are known from independent measurements. The Doppler shifted frequencies in the collinear experiment have been measured with a precision ofδv/v=6×10−9, mainly limited by the signal width of the resonance. A corresponding upper limit of 8×10−7 is deduced for any deviation of the ti…
The Crystal Barrel data acquisition system
1992
The main detector components of the Crystal Barrel (CBAR) experiment at the Low Energy Antiproton Ring (LEAR) at CERN are two proportional wire chambers, a jet drift chamber and an electromagnetic calorimeter composed of 1380 CsI(Tl) crystals, with a total of 4380 analog channels. A description is given of the use of distributed VME-based microcomputers to collect data from the various subdetectors and to merge the full event information in a global event builder. At this level the data are transferred to a mu VAX for tape storage and monitoring. >