Search results for "STRIPS"
showing 10 items of 55 documents
Recent advances in the development of high-resolution 3D cadmium-zinc-telluride drift strip detectors.
2020
In the last two decades, great efforts have been made in the development of 3D cadmium–zinc–telluride (CZT) detectors operating at room temperature for gamma-ray spectroscopic imaging. This work presents the spectroscopic performance of new high-resolution CZT drift strip detectors, recently developed at IMEM-CNR of Parma (Italy) in collaboration with due2lab (Italy). The detectors (19.4 mm × 19.4 mm × 6 mm) are organized into collecting anode strips (pitch of 1.6 mm) and drift strips (pitch of 0.4 mm) which are negatively biased to optimize electron charge collection. The cathode is divided into strips orthogonal to the anode strips with a pitch of 2 mm. Dedicated pulse processing analysis…
Precision Muon Reconstruction in Double Chooz
2014
We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volumes. All muons are fit under the hypothesis that they are through-going and ultrarelativistic. If the energy depositions suggest that the muon may have stopped, the reconstruction fits also for this hypothesis and chooses between the two via the relative goodness-of-fit. In the ideal case of a thro…
Construction of two large-size four-plane micromegas detectors
2015
We report on the construction and initial performance studies of two micromegas detector quadruplets with an area of 0.5 m$^2$. They serve as prototypes for the planned upgrade project of the ATLAS muon system. Their design is based on the resistive-strip technology and thus renders the detectors spark tolerant. Each quadruplet comprises four detection layers with 1024 readout strips and a strip pitch of 415 $\mu$m. In two out of the four layers the strips are inclined by $\pm$1.5$^{\circ}$ to allow for the measurement of a second coordinate. We present the detector concept and report on the experience gained during the detector construction. In addition an evaluation of the detector perfor…
Drawing and extruding: Theoretical and approximate formulas
1969
The problem of drawing of wires and of strips has been treated in several studies; among these the studies of Sachs seem essential. However, the results deduced according to similar theories are not always in accordance with the experimental results: reduction of area or of thickness are in fact usually smaller than those resulting from the theory. This is in dependance of the fact that Sachs has adopted the Limiting Condition of Yielding by v. Mises, according to which the limit values of stress in traction and compression are equal. More recently other AA. (Alberti, Noto La Diega, Bugini), admitting the Limiting Condition of Yielding by A. (or of the Paraboloid of Revolution) of which we …
Direkte Dickenmessung an Muskelstreifenpräparaten und Gewebsschnitten
1967
An apparatus for direct measurement of the thickness of tissue slices and muscle strips is described. Micrometer callipers are used, the proper adjustment of which is indicated by the sudden scale deflection of an ohmmeter. In comparison with the method of calculation based on a measurement of the area of the slice, this technique is time-saving and the results are more accurate and reproducible.
The analog Resistive Plate Chamber detector of the ARGO-YBJ experiment
2015
The ARGO-YBJ experiment has been in stable data taking from November 2007 till February 2013 at the YangBaJing Cosmic Ray Observatory (4300 m a.s.l.). The detector consists of a single layer of Resistive Plate Chambers (RPCs) (6700 m2) operated in streamer mode. The signal pick-up is obtained by means of strips facing one side of the gas volume. The digital readout of the signals, while allows a high space–time resolution in the shower front reconstruction, limits the measurable energy to a few hundred TeV. In order to fully investigate the 1–10 PeV region, an analog readout has been implemented by instrumenting each RPC with two large size electrodes facing the other side of the gas volume…
On the importance of background subtraction in the analysis of coronal loops observed with TRACE
2010
In the framework of TRACE coronal observations, we compare the analysis and diagnostics of a loop after subtracting the background with two different and independent methods. The dataset includes sequences of images in the 171 A, 195 A filter bands of TRACE. One background subtraction method consists in taking as background values those obtained from interpolation between concentric strips around the analyzed loop. The other method is a pixel-to-pixel subtraction of the final image when the loop had completely faded out, already used by Reale & Ciaravella 2006. We compare the emission distributions along the loop obtained with the two methods and find that they are considerably differen…
A large Streamer Chamber muon tracking detector in a high-flux fixed-target application.
1999
Arrays of limited streamer tubes of the Iarocci type were deployed in our experiment at CERN as part of a forward muon detector system with provisions for the beam to pass through the center of each panel in the array. A total of 16 4 m x 4 m panels were assembled with inductive readout strips on both sides of each panel. An active feedback system. was deployed to regulate the high voltage to the streamer tubes to insure a constant efficiency for minimum ionizing particles. The arrays were operated in this environment for over five years of data taking. Streamer tube track-reconstruction efficiencies and tube replacement rates are reported. (C) 1999 Elsevier Science B.V. All rights reserved.
A Demonstrator for a new Axial PET Concept
2008
In PET imaging, improving sensitivity while maintaining very good spatial resolution is crucial. To achieve this goal, we propose a novel concept of PET scanner, with axially arranged crystals, providing a high sensitivity and a 3D reconstruction of the gamma interaction point. The trans-axial coordinate is given by the crystal hit, while the z coordinate is reconstructed by the weighted distribution of light escaping the crystal and entering into an array of Wave Length Shifting (WLS) strips interleaving the crystal layers. This novel configuration allows full identification of Compton interactions in the crystals that can be included in image reconstruction thus enhancing the sensitivity.…
Silicon detectors for forward tracking in ATLAS
1996
Abstract A 12 cm long silicon microstrip detector module with a fan geometry has been designed and constructed. The performance of the detector has been studied in a test beam at CERN. Results are presented on the hit efficiency and the position resolution as a function of position along the strips. With a hit efficiency of 99.5% and a spatial resolution of typically 35 μm the performance of these detectors exceeds that of other candidate technologies for the precision forward tracker of the ATLAS inner detector.