Search results for "STRIPS"
showing 10 items of 55 documents
The AX-PET demonstrator—Design, construction and characterization
2011
Abstract Axial PET is a novel geometrical concept for Positron Emission Tomography (PET), based on layers of long scintillating crystals axially aligned with the bore axis. The axial coordinate is obtained from arrays of wavelength shifting (WLS) plastic strips placed orthogonally to the crystals. This article describes the design, construction and performance evaluation of a demonstrator set-up which consists of two identical detector modules, used in coincidence. Each module comprises 48 LYSO crystals of 100 mm length and 156 WLS strips. Crystals and strips are readout by Geiger-mode Avalanche Photo Diodes (G-APDs). The signals from the two modules are processed by fully analog front-end …
A Tracking and Timing (t-and-t) Front-end Electronics For Rpc Detectors
1992
Abstract The availability of a detector such as an RPC (resistive plate counter) opens new possibility on the future experiments for accelerator and non-accelerator physics. The main advantage consists on the possibility to obtain accurate tracking and timing with a low-cost detector and electronics. We report results on time resolution, signal transmission on long strips, efficiency and maintenance. A possible front-end electronics able to give tracking and timing information on each input channel operating in free-running mode will be illustrated toghether to the preliminary tests performed.
Experience with the ALEPH silicon vertex detector
1992
Abstract The ALEPH experiment [1] at LEP is equipped with a vertex detector [2] using two layers of double-sided silicon strip detectors. These detectors allow a real two-dimensional measurement of charged particle tracks. The present (1991) detector has the inner layer at a radius of 6.5 cm and the outer layer at 11.5 cm. The theta angle coverage is ±33° for the inner layer and ±50° for the outer layer. The inner layer is made out of 9 faces with four silicon detectors each, the outer layer has 15 such faces. We use silicon detectors of 5 × 5 cm 2 and 300 μm thickness. The readout pitch is 100 μm at both sides and using capacitive charge division a resolution in the order of 10 μm can be a…
STUDIES OF WIRE GAIN AND TRACK DISTORTION NEAR THE SECTOR EDGES OF THE ALEPH TIME PROJECTION CHAMBER
1986
Abstract The materials used to hold the wires at the sector edges in a large Time Projection Chamber (TPC) inrtoduce distortions of the electric drift field near those edges. These distortions degrade tracking information and sometimes cause large changes in wire gain near the edge. We have studied these two problems for the ALEPH TPC and have found that both can be greatly reduced by the addition of two field correction strips held at appropriate voltages.
Development of a High Precision Axial 3-D PET for Brain Imaging
2009
We describe a PET device based on a novel method to extract the coordinates of the interaction point of the 511keV γ rays from 100 mm long and thin LYSO (Lutetium Yttrium OxyorthoSilicate) scintillator bars, positioned axially in the tomograph. The coordinate along the hit crystal is measured by using a hodoscope of Wave Length Shifting (WLS) plastic strips mounted perpendicularly to each plane of scintillators. As photodetectors, new Geiger mode Avalanche PhotoDetectors (G-APDs) with integrated electronics are being used to detect both the hit crystal in a block (x and y coordinates) and the interaction point in the crystal (z coordinate) through the light escaping from the crystal and tra…
The AX-PET Concept: New Developments And Tomographic Imaging
2011
The Axial PET (AX-PET) concept proposes a novel detection geometry for PET, based on layers of long scintillating crystals axially aligned with the bore axis. Arrays of wavelength shifting (WLS) strips are placed orthogonally and underneath the crystal layers; both crystals and strips are individually readout by G-APDs. The axial coordinate is obtained from the WLS signals by means of a Center-of-Gravity method combined with a cluster algorithm. This design allows spatial resolution and sensitivity to be decoupled and thus simultaneously optimized. In this work we present the latest results obtained with the 2-module AX-PET scanner prototype, which consists of 6 radial layers of 8 LYSO crys…
Sub-kelvin current amplifier using DC-SQUID
2000
Abstract We have set up a system where a low-noise DC-SQUID is used as a current amplifier. The SQUID output is read using a wide band electronics unit based on the noise cancellation scheme. The SQUID has been installed in a compact Nanoway PDR50 dilution refrigerator, and superconducting transitions of Ti/Au thermometer strips for X-ray calorimeter applications have been measured. We can operate at 100 mK using a SQUID with Pd shunt resistors. Noise and bandwidth results of the setup are presented.
AX-PET: A novel PET detector concept with full 3D reconstruction
2009
We describe the concept and first experimental tests of a novel 3D axial Positron Emission Tomography (PET) geometry. It allows for a new way of measuring the interaction point in the detector with very high precision. It is based on a matrix of long Lutetium-Yttrium OxyorthoSilicate (LYSO) crystals oriented in the axial direction, each coupled to one Geiger Mode Avalanche Photodiode (G-APD) array. To derive the axial coordinate, Wave Length Shifter (WLS) strips are mounted orthogonally and interleaved between the crystals. The light from the WLS strips is read by custom-made G-APDs. The weighted mean of the signals in the WLS strips has proven to give very precise axial resolution. The ach…
Strength and strain enhancements of concrete columns confined with FRP sheets
2004
The compressive behavior up to failure of short concrete members reinforced with fiber reinforced plastic (FRP) is investigated. Rectangular cross-sections are analysed by means of a simplified elastic model, able also to explain stress-concentration. The model allows one to evaluate the equivalent uniform confining pressure in ultimate conditions referred to the effective confined cross-section and to the effective stresses in FRP along the sides of section; consequently, it makes it possible to determine ultimate strain and the related bearing capacity of the confined member corresponding to FRP failure. The effect of local reinforcements constitute by single strips applied at corners bef…
Debonding failure mechanisms in prestressed CFRP/epoxy/concrete connections
2014
Abstract This paper presents an investigation on the failure mode in prestress force-release tests of CFRP strips bonded to concrete substrates. Background of the study is the gradient anchorage technique. Firstly, experimental test series are presented. It is shown that considerable differences in failure mechanisms between lap-shear and the before mentioned release tests exist. The study reveals a strong Mode I-influence in the debonding process, compared to a Mode II for lap-shear tests. Secondly, FE simulations with a commercially available software are introduced. It is demonstrated that delamination in a force-release test occurs by a mixed-mode failure over the strip width.