Search results for "SUT"

showing 10 items of 768 documents

Long-term Results After Transconjunctival Resuturing of the Scleral Flap in Hypotony Following Trabeculectomy

2013

Purpose To present the 4-year follow-up results in the surgical treatment of hypotony following trabeculectomy with mitomycin C in glaucoma patients with additional flap sutures. Design Retrospective interventional case series. Methods Since 2006, 53 patients with hypotony maculopathy attributable to overfiltration following glaucoma surgery (trabeculectomy with mitomycin C) were included in this institutional study. We were able to follow up intraocular pressure (IOP) and distance-corrected visual acuity in 33 (62%) over 4 years, whereas all were followed over 2 years. To elevate IOP, we placed tangential transconjunctival sutures through the scleral flap and connected them to the adjacent…

AdultMaleReoperationIntraocular pressuremedicine.medical_specialtyTime FactorsVisual acuitygenetic structuresmedicine.medical_treatmentGlaucomaOcular HypotensionTrabeculectomySurgical FlapsTonometry OcularOphthalmologyGlaucoma surgeryHumansMedicineTrabeculectomyIntraocular PressureAgedRetrospective StudiesScleral flapAged 80 and overbusiness.industrySuture TechniquesMitomycin CGlaucomaMiddle Agedmedicine.diseaseeye diseasesScleraSurgeryOphthalmologyTreatment Outcomemedicine.anatomical_structureFemalesense organsmedicine.symptombusinessConjunctivaScleraFollow-Up StudiesAmerican Journal of Ophthalmology
researchProduct

The Penile Plication Procedure: An Alternative Method for Straightening Penile Deviation

1991

AbstractThe number of reported cases of congenital and acquired penile deviation is evidently increasing. We describe our experience with the penile plication procedure, which we used to treat 40 patients with penile deviation. Postoperatively, all patients regained the ability for sexual intercourse, with potency remaining unimpaired. Of the patients 96% were completely satisfied with the result of the operation. Sustained complications have not been observed. To avoid major trauma the surgical intervention should not include removal of ellipsoids from the penile tunica albuginea as proposed by Nesbit. Since the penile plication method produces equally good results in terms of performance …

AdultMaleReoperationmedicine.medical_specialtyAdolescentUrologyPenile IndurationTunica albuginea (ovaries)Postoperative ComplicationsRecurrenceMethodsmedicineHumansAlternative methodsPlicaturabiologybusiness.industrySuture TechniquesPenile Indurationbiology.organism_classificationSurgerymedicine.anatomical_structurebusinessPlication procedurePenisFollow-Up StudiesPenisJournal of Urology
researchProduct

Prevalence of acne vulgaris and its clinico-epidemiological pattern in adult patients: Results of a prospective, observational study.

2021

Background Acne is a common disorder in adolescents. The prevalence of acne in adults is also increasing. There are only a few Indian studies on the prevalence and clinical features of adult acne. Aims To evaluate the prevalence and possible etiological and aggravating factors of acne in adult population. Methods Adult patients more than 25 years with acne were enrolled, and detailed history and examination were recorded. Type of acne, age, gender, area of involvement, and associated factors were noted. Results Out of 24,056 adult patients, 180 had acne, with the prevalence of 0.74%. Mean age of patients with acne was 30.1 years. A total of 81.7% patients with acne were female and 68.3% had…

AdultMalemedicine.medical_specialtyAdolescentDermatologyCosmetics030207 dermatology & venereal diseases03 medical and health sciencesCicatrix0302 clinical medicineEpidemiologyAcne VulgarismedicinePrevalenceHumansProspective StudiesFamily historyhirsutismAcneGlycemicbusiness.industrymedicine.diseaseDermatology030220 oncology & carcinogenesisEtiologyPopulation studyObservational studyFemalebusinessJournal of cosmetic dermatologyREFERENCES
researchProduct

Importance of absorbable surgical sutures for the prevention of stitch abscess after surgery in patients with oral squamous cell carcinoma

2017

Background To elucidate the significance of absorbable surgical sutures in the occurrence of stitch abscess after surgery in patients with oral squamous cell carcinoma (SCC). Material and Methods The subjects were 251 patients who underwent excision and/or reconstruction and/or neck dissection for oral SCC using absorbable surgical sutures. Detection rates and characteristics of patients with stitch abscess were retrospectively evaluated by comparing between our present and previous data. Results There was only one stitch abscess among the 251 patients. A significant difference in the incidence of stitch abscess was found between the present data and our previous data. Of course, no signifi…

AdultMalemedicine.medical_specialtyAdolescentmedicine.medical_treatmentBiocompatible MaterialsStitch abscessYoung Adult03 medical and health sciencesPostoperative Complications0302 clinical medicinemedicineHumansSurgical Wound InfectionIn patientBasal cellGeneral DentistryAgedRetrospective StudiesAged 80 and overSuturesbusiness.industryResearchSignificant differenceNeck dissectionMiddle Aged:CIENCIAS MÉDICAS [UNESCO]AbscessSurgerystomatognathic diseasesOtorhinolaryngology030220 oncology & carcinogenesisUNESCO::CIENCIAS MÉDICASCarcinoma Squamous Cell030221 ophthalmology & optometryFemaleMouth NeoplasmsSurgeryOral SurgeryDetection ratebusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Sutureless ciliary sulcus supported intraocular lens with transiridal anchoring haptics.

2003

We report a technique for implanting intraocular lenses (IOLs) in the ciliary sulcus in eyes without capsule support. The IOL design allows it to be implanted without fixation sutures. The lens was implanted in 3 aphakic eyes without capsule support.

AdultMalemedicine.medical_specialtyCiliary sulcusgenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAphakia PostcataractProsthesis DesignFixation (surgical)Ciliary bodyLens Implantation IntraocularOphthalmologymedicineHumansAgedLenses Intraocularbusiness.industryCiliary BodySuture TechniquesCapsuleeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureIntraocular lensesSurgeryFemalesense organsbusinessJournal of cataract and refractive surgery
researchProduct

Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.

2006

ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…

AdultMalemedicine.medical_specialtyCorneal endotheliumBiometrygenetic structuresScheimpflug principleIrisAnterior surfacePhakic intraocular lensRefraction Ocularlaw.inventionLens Implantation IntraocularlawAnterior Eye SegmentCorneaOphthalmologyLens CrystallinemedicineMyopiaPhotographyHumansIris (anatomy)Retrospective StudiesLenses Intraocularbusiness.industrySuture Techniqueseye diseasesLens (optics)Ophthalmologymedicine.anatomical_structureSurgeryFemalesense organsbusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Tentacle-shaped mesh for fixation-free repair of umbilical hernias

2019

Purpose: Mesh fixation and broad overlap represent an open issue in umbilical hernia repair. A proprietary-designed implant with tentacle straps at its boundary has been developed to ensure a suture-free repair and a broader coverage of the abdominal wall. The study describes the results of umbilical hernia procedures carried out with the tentacle-shaped implant and the related surgical technique. Methods: A proprietary tentacle-shaped flat mesh having a central body with integrated radiating arms at its edge was used to repair large umbilical hernias in 62 patients. The implant was placed in preperitoneal sublay. The friction of the straps, crossing the abdominal wall thanks to a special n…

AdultMalemedicine.medical_specialtyHerniaHow-I-Do-Itmedicine.medical_treatmentNavelProsthesisProsthesis ImplantationAbdominal wallFixation freeRecurrenceUmbilicalmedicineHumansHerniaFreexationFriction forceHerniorrhaphyAgedUmbilicusTentacle meshbusiness.industryAbdominal WallSuture TechniquesProstheses and ImplantsMiddle AgedSurgical Meshmedicine.diseaseHernia repairUmbilical herniaSurgerySurgical meshmedicine.anatomical_structureHernia repairFemaleSurgeryImplantbusinessHernia UmbilicalHernia
researchProduct

Alterations in androgen conjugate levels in women and men with alopecia.

1994

Objective To assess levels of androgen metabolites thought to reflect, at least in part, peripheral androgen activity in women with androgenic alopecia and men with premature balding in an effort to determine if a common abnormality exists. Design Prospective study in various groups of women and men. Setting Reproductive Endocrine Clinic at our university medical center. Patients Ten normal ovulatory female controls and 50 hyperandrogenic women divided on the basis of hirsutism and alopecia as follows: [1] 8 hirsute women with androgenic alopecia; [2] 12 nonhirsute women with androgenic alopecia; [3] 18 hirsute women without androgenic alopecia; and [4] 12 nonhirsute women without androgeni…

AdultMalemedicine.medical_specialtyHirsutismAndrosterone glucuronideAdolescentmedicine.drug_classReference ValuesInternal medicinemedicineEndocrine systemHumansAndrostenedioneProspective StudieshirsutismSex Characteristicsbusiness.industryHyperandrogenismObstetrics and GynecologyAlopeciamedicine.diseaseAndrogenAndrosterone SulfateEndocrinologyReproductive MedicineAndrogensFemaleGlucuronidebusinessHyperandrogenismFertility and sterility
researchProduct

Endothelial cell loss after toric iris-fixated phakic intraocular lens implantation: three-year follow-up.

2007

ABSTRACT PURPOSE: To study quantitative changes in endothelial cell count after implantation of the toric iris-fixated phakic intraocular lens. METHODS: A prospective, non-randomized, self-controlled clinical trial was conducted of 40 eyes (28 myopic, 12 hyperopic) of 23 patients with high ametropia and astigmatism. Non-contact computer-assisted endothelial microscopy was performed before and I1 2, and 3 years after surgery. RESULTS: In the myopic group, mean preoperative endothelial cell count was 3179±531 cells/mm p 2 (range: 1800 to 3900 cells/mm2). The mean intraindividual endothelial cell loss was -1.83±2.25% (range: -9.09% to 0%) in the first year; -1.83+2.95% (range: -7.74% to 3.80%)…

AdultMalemedicine.medical_specialtyTime FactorsIrisCell CountAstigmatismPhakic intraocular lensEndothelial cell countCorneal DiseasesPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineMedicineHumansProspective Studiesbusiness.industryEndothelium CornealSuture TechniquesMiddle Agedmedicine.diseaseCell lossRefractive Surgical ProceduresEndothelial stem cellOphthalmologySurgeryFemalebusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Simplified Orthotopic Ileocecal Pouch (Mainz Pouch) for Bladder Substitution

2003

Objective To report operative modifications that render construction of the orthotopic Mainz pouch more simple, namely formation of the pouch using absorbable staples and utilization of the ileocecal valve as an antireflux mechanism. Patients and methods Between January 2001 and May 2002 out of 92 cystectomy cases, 21 patients (20 males and 1 female) underwent a simplified orthotopic Mainz pouch. The ureters were implanted via Wallace or Nesbit technique in the supravalvular portion of the ileocecal valve. The mean (range) age was 58 (43 - 74) years and the mean follow-up is 11.6 months (range 1 - 27). Results No staple-related complications were encountered. Four renal units (8.8 %) were d…

AdultMalemedicine.medical_specialtyTime FactorsUrologymedicine.medical_treatmentUrinary DiversionCystectomyKidney Function TestsUrinary catheterizationCystectomyKock pouchIleocecal valveSurgical StaplersIleumHumansMedicineCecumAgedProstatectomySuturesPelvic exenterationbusiness.industryRefluxMiddle AgedPelvic ExenterationSurgerymedicine.anatomical_structureFemaleUreterPouchUrinary CatheterizationbusinessContinent Urinary DiversionFollow-Up StudiesAktuelle Urologie
researchProduct