Search results for "SWI"

showing 10 items of 1473 documents

Minimal Reporting Standards for Active Middle Ear Hearing Implants.

2017

There is currently no standardized method for reporting audiological, surgical and subjective outcome measures in clinical trials with active middle ear implants (AMEIs). It is often difficult to compare studies due to data incompatibility and to perform meta-analyses across different centres is almost impossible. A committee of ENT and audiological experts from Germany, Austria and Switzerland decided to address this issue by developing new minimal standards for reporting the outcomes of AMEI clinical trials. The consensus presented here aims to provide a recommendation to enable better inter-study comparability.

medicine.medical_specialtyConsensusPhysiologyHearing lossHearing Loss Sensorineural610 Medicine & healthAudiology03 medical and health sciencesSpeech and Hearing0302 clinical medicineHearing AidsHearingGermanyOutcome Assessment Health CaremedicineHumans610 Medicine & health030223 otorhinolaryngologyOriginal Paperbusiness.industryHearing TestsComparabilityOutcome measuresAudiogramSensory SystemsClinical trialOssicular Prosthesismedicine.anatomical_structureTreatment OutcomeOtorhinolaryngologyHearing resultsMeta-analysisAustriaMiddle earmedicine.symptombusiness030217 neurology & neurosurgerySwitzerlandAudiologyneuro-otology
researchProduct

Cost effectiveness of peginterferon α-2b plus ribavirin versus interferon α-2b plus ribavirin for initial treatment of chronic hepatitis C

2003

Background: Peginterferon α-2b plus ribavirin therapy in previously untreated patients with chronic hepatitis C yields the highest sustained virological response rates of any treatment strategy but is expensive. Aims: To estimate the cost effectiveness of treatment with peginterferon α-2b plus ribavirin compared with interferon α-2b plus ribavirin for initial treatment of patients with chronic hepatitis C. Methods: Individual patient level data from a randomised clinical trial with peginterferon plus ribavirin were applied to a previously published and validated Markov model to project lifelong clinical outcomes. Quality of life and economic estimates were based on German patient data. We u…

medicine.medical_specialtyCost effectivenessbusiness.industryRibavirinGastroenterologyvirus diseasesAlpha interferonHepatitis CWirtschaftswissenschaftenmedicine.diseaseGastroenterologySurgeryQuality-adjusted life yearClinical trialchemistry.chemical_compoundchemistryInternal medicinemedicinebusinessViral loadInterferon alfamedicine.drug
researchProduct

Isolation and colture of beta-like cells from porcine Wirsung duct

2009

We sought to develop a protocol to isolate and culture porcine Wirsung duct cells in order to determine their potency to differentiate into insulin-expressing beta-like cells. The porcine Wirsung duct isolated by a surgical microdissection was digested with collagenase P and trypsin to dissociate ductal cells. These elements were cultured in serum-free supplemented media: for 2 weeks. Thereafter the cells were exposed to varying concentrations of glucose (0, 5.6, 17.8, and 25 mmol/L) to induce a beta-like phenotype, as identified by immunohistochemical staining. Cell growth proceeded slowly for the first 2 weeks of culture. After glucose induction for 2 weeks, they formed pancreatic islet-l…

medicine.medical_specialtyDuctal cellsSwinemedicine.medical_treatmentBiologyGlucagonchemistry.chemical_compoundIslets of LangerhansInternal medicinemedicineAnimalsInsulinCells CulturedKeratin-19TransplantationInsulinPancreatic DuctsTrypsinGlucagonMolecular biologyStainingTransplantationSettore MED/18 - Chirurgia GeneraleEndocrinologyL-GlucosechemistryCollagenaseSurgeryBeta like cells pancreasporcine Wirsung ducttransdifferentiationBiomarkersmedicine.drug
researchProduct

An experimental study on long term outcomes after magnetic esophageal compression anastomosis in piglets

2021

Abstract Background/Purpose Previous studies have shown that a patent, watertight esophageal anastomosis can be accomplished safely using specially-shaped magnets in piglets. However, it is unclear whether such a magnetic esophageal compression anastomosis (MECA) remains patent in the long-term. The purpose of this study was to evaluate the long-term outcome of MECA in an experimental pig model over an observation period of 2 months. Methods Ten piglets underwent creation of an MECA with custom-made 8 mm magnets and a U-shaped esophageal bypass loop to allow peroral nutrition at eight weeks of life. Two weeks later, the bypass loop was closed surgically, requiring the pigs to swallow via th…

medicine.medical_specialtyEndoscopeSwineAnastomosisMagneticsmedicineAnimalsEsophagusEsophageal Atresiabusiness.industryMagnetic PhenomenaAnastomosis SurgicalGeneral Medicinemedicine.diseaseDysphagiaConfidence intervalSurgerymedicine.anatomical_structureAtresiaPediatrics Perinatology and Child HealthMagnetsSurgeryHistopathologymedicine.symptombusinessWeight gainJournal of Pediatric Surgery
researchProduct

Factors Affecting Flutter Kicking Speed in Women Who Are Competitive and Recreational Swimmers

2009

The purpose of this study was to determine the relationships between possible predictive measures of a 50 m front crawl swimming and a 22.86 m flutter kicking speed. Ten women who were National Collegiate Athletic Association Division I collegiate swimmers and 10 women who were recreational swimmers (mean +/- SD = 20.6 +/- 1.6 years; 66.7 +/- 10.3 kg; 166.7 +/- 8.8 cm) volunteered for the study. Anthropometric measures were obtained including height, leg length, lower leg length, and foot length. Ankle flexibility was assessed by measuring ankle plantar flexion and ankle inversion. Lower body power was measured using a vertical jump. Swimming and kicking speed were measured as the time to c…

medicine.medical_specialtyFlexibility (anatomy)Ankle inversionPhysical Therapy Sports Therapy and RehabilitationAthletic PerformanceYoung AdultVertical jumpmental disordersmedicineHumansOrthopedics and Sports MedicineRange of Motion ArticularSwimmingAgedLegGeneral Medicinebody regionsmedicine.anatomical_structurePhysical therapyFlutterFemaleAnklePsychologyRange of motionhuman activitiesFront crawlAnkle JointLower Leg LengthJournal of Strength and Conditioning Research
researchProduct

Effects of three different water temperatures on dehydration in competitive swimmers

2011

Summary Aims The purpose of this study was to evaluate the effects of three different water temperatures on physiological responses (dehydration, sweat rate, urine output, rectal temperature and plasma electrolytes) of competitive athletes during a “simulated” race of 5 km in an indoor swimming pool. Methods Nine male competitive master swimmers swam 5 km with the water at temperatures of 23, 27 and 32 C. Immediately before (Pre) and after (Post) each trial, samples of blood and urine were collected, body weight was recorded and rectal temperature was measured. The dehydration percentage and sweat rate were the highest at 32 C and the lowest at 23 C (23 C: −0.9 ± 0.5; 27 C: −1.3 ± 0.6; 32 C…

medicine.medical_specialtyFluid balance body temperatures plasma electrolytesSettore BIO/16 - Anatomia UmanaChemistryRectal temperatureUrinemedicine.diseaseBody weightSettore BIO/09 - Fisiologiafluid balancePhysiological responsesSurgeryrectal temperatureSWEATopen water; swimming; sweat rate; fluid balance; performance; rectal temperatureAnimal scienceOpen watersweat rateopen watermedicineOrthopedics and Sports MedicineDehydrationswimmingperformanceUrine outputScience & Sports
researchProduct

Prosthetic strap system for simplified ventral hernia repair. Its results in a porcine experimental model.

2010

Abstract: Introduction Aiming to achieve a simplified ventral hernia repair, a proprietary shaped mesh was experimentally tested in the porcine model. The mesh is structured with a large central body and radiating straps. The friction of the straps passing through the tissues are hypothesized to be adequate to maintain the mesh in place during tissue ingrowth, avoiding classic point fixation while ensuring a wide coverage of the abdomen. Methods The mesh, having 6 radial straps, was placed using a sublay preperitoneal technique in 4 pigs. All straps were passed laterally through the abdominal wall and exteriorized from the skin. The straps were trimmed at the level of the skin, allowing the…

medicine.medical_specialtyFrictionSwineProsthesis ImplantationFixation (surgical)Ventral hernia; Prostheses and implants; Incorporation;Surgical fixation devices; FrictionmedicineAnimalsHerniaIncorporationProstheses and implantWound HealingSurgical fixation deviceVentral hernia repairExperimental modelSurgical Fixation Devicebusiness.industryAnatomySurgical Meshmedicine.diseaseHernia VentralSurgerybody regionsSettore MED/18 - Chirurgia GeneraleSurgical meshVentral herniaVentral herniaModels AnimalFeasibility StudiesSurgerybusinessTissue ingrowth
researchProduct

Developmental and tumoral vascularization is regulated by G protein-coupled receptor kinase 2

2012

Tumor vessel dysfunction is a pivotal event in cancer progression. Using an in vivo neovascularization model, we identified G protein–coupled receptor kinase 2 (GRK2) as a key angiogenesis regulator. An impaired angiogenic response involving immature vessels was observed in mice hemizygous for Grk2 or in animals with endothelium-specific Grk2 silencing. ECs isolated from these animals displayed intrinsic alterations in migration, TGF-β signaling, and formation of tubular networks. Remarkably, an altered pattern of vessel growth and maturation was detected in postnatal retinas from endothelium-specific Grk2 knockout animals. Mouse embryos with systemic or endothelium-selective Grk2 ablation …

medicine.medical_specialtyG-Protein-Coupled Receptor Kinase 2Angiogenic SwitchAngiogenesisMedicinaActivin Receptors Type IIMelanoma ExperimentalReceptor Transforming Growth Factor-beta Type INeovascularization PhysiologicProtein Serine-Threonine KinasesBiologyMural cellGrk2Transforming Growth Factor beta1NeovascularizationMiceDownregulation and upregulationCell MovementPregnancyInternal medicinemedicineAnimalsHumansCell ProliferationHemizygoteMice KnockoutG protein-coupled receptor kinaseTumorNeovascularization PathologicEndothelial CellsRetinal VesselsG proteinGeneral MedicineCell biologyEndocrinologymedicine.anatomical_structurecardiovascular systemFemalePericyteSignal transductionmedicine.symptomActivin Receptors Type IReceptors Transforming Growth Factor betaSignal TransductionResearch Article
researchProduct

Bile Duct Warmer in Hepatic Cryosurgery—A Pig Liver Model

1998

Freezing of the common bile duct resulted in injury, stenosis, or perforation of the bile duct in a dog model. Biliary cutaneous fistulas and bile leaks are reported as complications of hepatic cryosurgery in man. In an ex vivo pig liver model we compared freezing close to the bile duct with and without warming the bile duct with warmed saline solution via an inserted catheter ("bile duct warmer"). The recorded temperatures at the outer wall of the bile duct were -50 degrees C after 10 min of freezing without and 5. 8 degrees C with the use of the warmer (P0.001, two-way ANOVA). The bile duct warmer system may be a simple and inexpensive device in reducing perioperative morbidity after hepa…

medicine.medical_specialtyHot TemperatureSwinemedicine.medical_treatmentPerforation (oil well)Sodium ChlorideCryosurgeryModels Biologicaldigestive systemGastroenterologyGeneral Biochemistry Genetics and Molecular BiologyCryosurgeryCatheterizationDogsPostoperative ComplicationsInternal medicinemedicineAnimalsHumansSalineCommon bile ductBile ductbusiness.industryLiver NeoplasmsGeneral Medicinemedicine.diseaseStenosisCathetermedicine.anatomical_structureLiverEvaluation Studies as TopicBiliary tractBile DuctsGeneral Agricultural and Biological SciencesbusinessCryobiology
researchProduct

An experimental study on magnetic esophageal compression anastomosis in piglets.

2019

Abstract Introduction Fashioning a patent, watertight anastomosis in patients with esophageal atresia is a challenging task in pediatric surgery, particularly when performed under tension. A reproducible suture-less alternative would decrease operative time. We evaluated magnetic esophageal compression anastomoses in a novel bypass-loop swine model. Methods Eight-week-old piglets underwent thoracotomy to mobilize the esophagus at the carina to create a U-shaped loop. Custom-made 8 mm diameter Neodymium Magnets were inserted into the esophagus proximal and distal to the loop, then mated side-to-side at the future anastomosis site. Pigs were observed for 8 (n = 4), 10 (n = 6), and 12 (n = 2) …

medicine.medical_specialtyLeakSwinemedicine.medical_treatmentRadiographyAnastomosis03 medical and health sciences0302 clinical medicineEsophagusPregnancy030225 pediatricsPediatric surgerymedicineAnimalsThoracotomyEsophagusEsophageal Atresiabusiness.industryAnastomosis SurgicalGeneral Medicinemedicine.diseaseSurgeryDisease Models Animalmedicine.anatomical_structure030220 oncology & carcinogenesisAtresiaPediatrics Perinatology and Child HealthMagnetsSurgeryHistopathologyFemalebusinessJournal of pediatric surgery
researchProduct