Search results for "Sagittal plane"
showing 10 items of 105 documents
A classification study of kinematic gait trajectories in hip osteoarthritis
2014
The clinical evaluation of patients in hip osteoarthritis is often done using patient questionnaires. While this provides important information it is also necessary to continue developing objective measures. In this work we further investigate the studies concerning the use of 3D gait analysis to attain this goal. The gait analysis was associated with machine learning methods in order to provide a direct measure of patient control gait discrimination. The applied machine learning method was the support vector machine (SVM). Applying the SVM on all the measured kinematic trajectories, we were able to classify individual patient and control gait cycles with a mean success rate of 88%. With th…
Comparison of posturographic parameters between young taekwondo and tennis athletes
2018
[Purpose] Physical activity can influence the development of postural control and balance. Therefore, the aim of study was to use posturography assessment to compare balance control on the Romberg test between athletes in two very different sports, taekwondo and tennis. [Participants and Methods] Twenty-nine young athletes participated in the study, 11 forming the taekwondo group and 18 the tennis group. Posturography was performed using the FreeMed system (Sensor Medica). Between-group differences were evaluated using unpaired Student’s t-test. [Results] There was a significance between-group difference in the centre of pressure and the ellipse surface area with no between-group difference…
Three dimensional reliability analyses of currently used methods for assessment of sagittal jaw discrepancy
2018
Background The objective of this study was to analyse three dimensionally the reliability and correlation of angular and linear measurements in assessment of anteroposterior skeletal discrepancy. Material and Methods In this retrospective cross sectional study, a sample of 213 subjects were three-dimensionally analysed from cone-beam computed tomography scans. The sample was divided according to three dimensional measurement of anteroposterior relation (ANB angle) into three groups (skeletal Class I, Class II and Class III). The anterior-posterior cephalometric indicators were measured on volumetric images using Anatomage software (InVivo5.2). These measurements included three angular and s…
True vertical validation in facial orthognathic surgery planning
2013
Objectives: To validate the effectiveness of the original standards of True Vertical (TV) Subnasal Line in orthognatic surgery planning. The present study evaluates the changes occurring in patients with skeletal Class II alterations programmed for orthognathic surgery with a view to improving their facial profile. Study design: We showed a series of black profiles (composed by a first control group of subjects with normal occlusion, and another two additional groups comprised patients before –Group 2- and after orthognatic surgical correction of Class II malocclusion -Group 3-) for three groups of observers (orthodontists, surgeons and laypeople). The facial images became black silhouettes…
Shape indices to identify regional differences in otolith morphology of comber, Serranus cabrilla (L., 1758)
2003
Summary Sagittal otoliths from the Atlantic and Mediterranean regions of Serranus cabrilla L. were compared using shape indices (form-factor, roundness, circularity, rectangularity, ellipticity and eccentricity). Regional differences were best described by form-factor, circularity and eccentricity variables. The canonical discriminant functions were built with form-factor or rectangularity indices. The results indicated slight regional variations. The G-test was the criterion more useful to identify the otolith origin in the discriminant analysis.
Morphological Analysis Combined with a Machine Learning Approach to Detect Utrasound Median Sagittal Sections for the Nuchal Translucency Measurement
2017
The screening of chromosomal defects, as trisomy 13, 18 and 21, can be obtained by the measurement of the nuchal translucency thickness scanning during the end of the first trimester of pregnancy. This contribution proposes an automatic methodology to detect mid-sagittal sections to identify the correct measurement of nuchal translucency. Wavelet analysis and neural network classifiers are the main strategies of the proposed methodology to detect the frontal components of the skull and the choroid plexus with the support of radial symmetry analysis. Real clinical ultrasound images were adopted to measure the performance and the robustness of the methodology, thus it can be highlighted an er…
Influence of enhancement filters in apical bone loss measurement: A cone-beam computed tomography study
2016
Background The use of cone-beam computed tomography images (CBCT) providing a better assessment of bone injuries, although the sensibility of lesions measurement might be improved by the use of enhancement filters. Objective: This study aimed to analyze the influence of enhancement filters in apical bone loss measurement. Material and Methods Eighteen CBCT cases randomly selected of apical bone loss were evaluated. The analyses were carried out following the evaluation in axial, coronal and sagittal protocols, using enhancement filters as Hard, Normal, and Very Sharp. The variables were statistically analyzed by Friedman and Wilcoxon test, Spearman’s rho, and intraclass correlation coeffici…
Energy-related optimal control accounts for gravitational load: comparing shoulder, elbow, and wrist rotations.
2013
International audience; Gaveau J, Berret B, Demougeot L, Fadiga L, Pozzo T, Papaxanthis C. Energy-related optimal control accounts for gravitational load: comparing shoulder, elbow, and wrist rotations. J Neurophysiol 111: 4-16, 2014. First published October 16, 2013; doi: 10.1152/jn.01029.2012.-We permanently deal with gravity force. Experimental evidences revealed that moving against gravity strongly differs from moving along the gravity vector. This directional asymmetry has been attributed to an optimal planning process that optimizes gravity force effects to minimize energy. Yet, only few studies have considered the case of vertical movements in the context of optimal control. What kin…
Is backward disequilibrium in the elderly caused by an abnormal perception of verticality? A pilot study
2007
International audience; OBJECTIVE: We hypothesised that backward disequilibrium (BD), defined by a posterior position of the centre of mass with respect to the base of support, could be caused by a backward tilt in the perception of verticality. METHODS: The relationship between BD, the perception of verticality, and the history of falls in 25 subjects aged 84.5+/-7.4 years was analysed. An original ordinal scale, the BD scale (BDS), was used to quantify BD. Postural (PV) and haptic verticals (HV) were measured in sagittal plane. RESULTS: BDS scores closely correlated with the number of falls (r = 0.81, p =10(-5)). The more the PV was tilted backward, the greater the BDS scores (r = -0.95, …
Neck Pain Rehabilitation
2016
Neck pain is par excellence one of the most common disorders of the musculoskeletal system, second only to low back pain. It constitutes 40 % of all backache. The International Association for the Study of Pain (IASP) defines pain of cervical origin coming from an area between the nuchal line and another imagi-nary line that passes through the lower end of the spinous process of the first thoracic vertebra and the sagittal plans tangent to the side edges of the neck. This definition considers therefore posterior pain which in turn can be divided into high pain, up to C3, and lower pain, down from C4. Also, as all diseases, it can be divided into acute and chronic neck pain, merely according…