Search results for "Sample"
showing 10 items of 2270 documents
A new selective method for dimethylamine in water analysis by liquid chromatography using solid-phase microextraction and two-stage derivatization wi…
2005
Abstract A new method is presented for the determination of DMA in water as its 9-fluorenylmethyl chloroformate (FMOC) derivative using solid-phase microextraction (SPME) and liquid chromatography. The method is based on the employment of SPME fibres coated with carbowax-templated resin (CW-TR) for analyte extraction and derivatization. The fibres were successively immersed in the samples, in a solution of o -phthalaldialdehyde and N -acethyl- l -cysteine (OPA–NAC) and finally, in a solution of FMOC. OPA–NAC reacted on the fibre with possible primary aliphatic amines present in the samples, particularly with PA which is a direct interferent in the determination of DMA with FMOC. In such a w…
Method and apparatus using selected superparamagnetic labels for rapid quantification of immunochromatographic tests
2009
Mika PA Laitinen1, Jari Salmela2, Leona Gilbert1, Risto Kaivola1, Topi Tikkala2, Christian Oker-Blom1, Jukka Pekola3, Matti Vuento11Department of Biological and Environmental Science; 2Department of Physics, University of Jyväskylä, Jyväskylä, Finland; 3Low Temperature Laboratory, Helsinki University of Technology, Helsinki, FinlandAbstract: A rapid method and instrumentation for quantification of immunochromatographic tests (ICT) are described. The principle and performance of the method was demonstrated by measuring the levels of human chorionic gonadotropin (hCG) present in urine. The test format was a sandwich assay using two distinct monoclonal antib…
On-line bidirectional electrostacking of chromium(III) and chromium(VI) for flame atomic absorption spectrometry determination
2000
Abstract An on-line bidirectional electrostacking-flow injection-flame atomic absorption spectrometry method has been developed for the simultaneous separation, pre-concentration and determination of Cr(III) and Cr(VI). The electrostacking-flow injection unit was established, the pH and components of the support buffer and sample medium were investigated. Results indicated that the ionic mobility, electric field strength and sample area cross-section are the main influence factors on the electrostacking. The calibration range for both, Cr(III) and Cr(VI), was from 20 to 400 μg l −1 . The limit of detection was 7 μg l −1 for three-times the standard deviation of blank values using a electros…
Fourier-transform infrared determination of nicotine in tobacco samples by transmittance measurements after leaching with CHCl3
1998
Abstract A new procedure is proposed for the FT-IR spectrometric determination of nicotine in tobacco. The method is based on the extraction of nicotine in CHCl 3 from tobacco samples, wetted with an aqueous solution of NH 3 (0.1 M), and the measurement of absorbance in the stopped-flow mode at 1316 cm −1 , using a spectral baseline correction established from 1334 to 1300 cm −1 . The procedure developed does not requires a complex sample preparation, and provides a limit of detection of 0.045 mg ml −1 nicotine, a sampling frequency of 3.3 h −1 and a coefficient of variation of 0.3% for five independent measurements of a tobacco sample with a nicotine content of 1.5% w/w. The accuracy of th…
Determination of 129I/127I isotope ratios in liquid solutions and environmental soil samples by ICP-MS with hexapole collision cell
2003
The determination of I-129 in environmental samples at ultratrace levels is very difficult by ICP-MS due to a high noise caused by Xe impurities in argon plasma gas (interference of Xe-129(+)), possible (IH2+)-I-127 interference and an insufficient abundance ratio sensitivity of the ICP mass spectrometer for I-129/I-127 isotope ratio measurement. A sensitive, powerful and fast analytical technique for iodine isotope ratio measurements in aqueous solutions and contaminated soil samples directly without sample preparation using ICP-MS with a hexapole collision cell (ICP-CC-QMS) was developed. Oxygen is used as reaction and carrier gas for iodine thermal desorption via the gas phase from solid…
Flow injection flame atomic absorption analysis of Fe and Mn in cement samples
1993
A new procedure has been developed for the determination of Fe and Mn in cements. It consists in dispersing 50 mg of the solid sample in 25 ml of 0.15 mol/l HNO3 and 0.12 mol/l HCl solution. Acid slurries are heated at 50°C for 10 min and then different volumes of the slurry are injected into a water carrier stream. This previous acid treatment leaches the elements to be determined and permits the use of acid solutions as standards. For the Mn determination, the use of a single line flow injection manifold provides a limit of detection of 0.03 mgl−1 and a dynamic range up to 6 mgl−1. For the determination of Fe, the on-line dispersion of samples, using a well stirred mixing chamber, increas…
Optimization of a microwave-assisted extraction large-volume injection and gas chromatography–ion trap mass spectrometry procedure for the determinat…
2006
Abstract A sensitive and rapid method for the determination of polybrominated diphenyl ethers (PBDEs), polybrominated biphenyls (PBBs) and polychlorinated naphthalenes (PCNs) in sediment samples is proposed. The method involving microwave-assisted extraction (MAE) and large-volume injection (LVI) gas chromatography (GC)–ion trap mass spectrometry (ITMS), and the experimental conditions were optimized using the statistical design of experiments (DOE). A Plackett–Burman (P–B) design was chosen to estimate the influence of five factors, such as resonance excitation voltage (EV), isolation time (IT), excitation time (ET), ion source temperature (IST) and electron energy (EE) on the analytical r…
Determination of fungicide residues in fruits and vegetables by liquid chromatography–atmospheric pressure chemical ionization mass spectrometry
2002
Abstract A liquid chromatography (LC) method for the quantitative determination of five fungicide residues (dichloran, flutriafol, o -phenylphenol, prochloraz and tolclofos methyl) in oranges, lemons, bananas, peppers, chards and onions is described. The residues were extracted by matrix solid-phase dispersion (MSPD) using C 8 . Quantitative analysis was performed by isocratic LC coupled to quadrupole mass spectrometer using atmospheric pressure chemical ionization in the negative ionization mode. The limit of quantification was 0.01 mg kg −1 for flutriafol, o -phenylphenol and dichloran, and 0.1 mg kg −1 for prochloraz and tolclofos methyl. The MSPD method is also suitable for LC–UV analys…
A tandem-flow assembly for the chemiluminometric determination of hydroquinone
2003
A direct chemiluminescent procedure for determination of hydroquinone based on the emergent flow methodology known as multicommutation or tandem-flow is presented for first time. The manifold was based on a set of three channels and three solenoid valves; and, the determination was performed at 60degreesC and at flow-rate of 7.5 ml min(-1). The complete cycle lasted 35 s, which resulted in a sample flow trough of 103 h(-1). The chemical process was the hydroquinone oxidation with the system sulphuric acid-potassium permanganate; and the light emission was clearly enhanced by the presence of quinine sulphate and benzalkonium chloride reaching a detection limit of 30 Rg l(-1). The dynamic int…
Improvement of the detection limit for determination of 129I in sediments by quadrupole inductively coupled plasma mass spectrometer with collision c…
2004
The previously developed sample introduction device for the hot extraction of iodine from environmental samples (soils or sediments) and on-line introduction of analyte via the gas phase in quadrupole inductively coupled plasma mass spectrometry with hexapole collision cell (ICP-CC-QMS) was equipped with a cooling finger, which allowed intermediate iodine enrichment and improved the detection limits for I-129 down to 0.4 pg g(-1) without any additional sample preparation. A mixture of oxygen and helium as reaction gases in the hexapole collision cell was used for reducing the disturbing background intensity of Xe-129(+). Oxygen was also used as the carrier gas for iodine thermal desorption …