Search results for "Samples"

showing 10 items of 133 documents

Liquid membranes as a sample preparation method in environmental analysis

2014

Because of the complexity of environmental matrices, there is a great need of application efficient sample preparation procedures for environmental analysis. One of such possibilities is using, during sample-pretreatment step, the membrane extraction (ME) methods. They include, for instance, a three-phase extraction system named supported liquid membranes that has been used in recent years many times for isolation and preconcentration of various analytes from complex sample matrices. The examples of application the commonly used types of SLMs, hollow fiber supported liquid membrane and flat sheet supported liquid membrane, are listed and described. Additionally, the area of membrane extract…

liquid membranesmembrane extractionenvironmental samples analysissample enrichment
researchProduct

Evaluation of Superparamagnetic Silica Nanoparticles for Extraction of Triazines in Magnetic in-Tube Solid Phase Microextraction Coupled to Capillary…

2014

The use of magnetic nanomaterials for analytical applications has increased in the recent years. In particular, magnetic nanomaterials have shown great potential as adsorbent phase in several extraction procedures due to the significant advantages over the conventional methods. In the present work, the influence of magnetic forces over the extraction efficiency of triazines using superparamagnetic silica nanoparticles (NPs) in magnetic in tube solid phase microextraction (Magnetic-IT-SPME) coupled to CapLC has been evaluated. Atrazine, terbutylazine and simazine has been selected as target analytes. The superparamagnetic silica nanomaterial (SiO2-Fe3O4) deposited onto the surface of a capil…

magnetic nanoparticlesChromatographyMaterials scienceMagnetismGeneral Chemical EngineeringExtraction (chemistry)Solid-phase microextractionMagnetic susceptibilityArticleNanomaterialslcsh:ChemistryAdsorptionlcsh:QD1-999magnetic nanoparticles; triazines; magnetic susceptibility; on-line solid phase microextraction; environmental samplestriazinesenvironmental samplesMagnetic nanoparticlesGeneral Materials Scienceon-line solid phase microextractionmagnetic susceptibilitySuperparamagnetismNanomaterials
researchProduct

Tips and tricks for flow cytometry-based analysis and counting of microparticles

2015

Submicron-sized extra-cellular vesicles generated by budding from the external cell membranes, microparticles (MPs) are important actors in transfusion as well as in other medical specialties. After briefly positioning their role in the characterization of labile blood products, this technically oriented chapter aims to review practical points that need to be considered when trying to use flow cytometry for the analysis, characterization and absolute counting of MP subsets. Subjects of active discussions relative to instrumentation will include the choice of the trigger parameter, possible standardization approaches requiring instrument quality-control, origin and control of non-specific ba…

medicine.diagnostic_testPlasma samplesbusiness.industryHematologyLimitingFlow CytometryFlow cytometryCell-Derived MicroparticlesImmunologymedicineEnumerationAnimalsHumansInstrumentation (computer programming)businessBiomedical engineeringTransfusion and Apheresis Science
researchProduct

Untersuchungen zur Aktivit�tskinetik des Isoenzymes CK-MB im Serum nach Myokardinfarkt

1978

We investigated the activity kinetics of CK-total and CK-MB in 83 patients with proven myocardial infarctions. Serial serum samples were taken at intervals of 2--6 h. The activity of isoenzym CK-MB was determined by means of the immunological inhibition method. CK-MB activity was determined in all patients. The mean peak activity of CK-MB was 65 U/l (range: 9-241 U/l). At the time of peak CK-MB activity the mean percentage CK-MB activity was 13.2% (range: 3.4--21.7%). The CK-MB activity reached its peak at 17.4 h (range: 3.0--32.5 h) after the onset of retrosternal pain. This is 1.4 h after peak CK-total activity. The mean disappearance rate constant for CK-MB (n = 31) was found to be 9.3 X…

medicine.medical_specialtyChemistryDisappearance rateHalf-lifeGeneral MedicineRetrosternal painmedicine.diseaseSerum samplesIsozymeEndocrinologyInternal medicineDrug DiscoverymedicineMolecular MedicineCircadian rhythmMyocardial infarctionGenetics (clinical)Klinische Wochenschrift
researchProduct

Hepatitis B virus in diabetic patients

1980

The presence of HBV markers was determined in 149 serum samples obtained from diabetic patients and was compared with a normal population. Diabetics have the same incidence of HBsAg but significantly higher anti-HBc antibodies. These differences were seen in the group of diabetics on oral hypoglycemic therapy. These results cannot yet be explained.

medicine.medical_specialtyHBsAgEndocrinology Diabetes and MetabolismHbv markersAntibodies Viralmedicine.disease_causeGastroenterologyHepatitis B AntigensEndocrinologyInternal medicineDiabetes mellitusEpidemiologyDiabetes MellitusInternal MedicinemedicineHumansHepatitis B AntibodiesHepatitis B virusbiologybusiness.industryIncidence (epidemiology)virus diseasesGeneral MedicineSerum samplesmedicine.diseasedigestive system diseasesImmunologybiology.proteinAntibodybusinessActa Diabetologica Latina
researchProduct

Effects of diazinon exposure on cholinesterase activity in different tissues of European eel (Anguilla anguilla).

1996

Cholinesterase (ChE) activity was measured in brain, plasma, and whole eye of Anguilla anguilla experimentally exposed to a sublethal concentration of 0.042 mg/liter (0.50 of the 96-hr LC50) of the organophosphorous pesticide diazinon. Whole eye was the tissue which revealed higher values of ChE activity (8.17 micromol/min/g) in nonexposed animals. Brain, plasma, and whole eye ChE activity of A. anguilla was inhibited at 6, 24, 48, 72, and 96 hr of diazinon exposure. Pesticide induced significant inhibitory effects on the ChE activity of this species ranging from >70% inhibition in brain tissue to >90% in plasma samples. Brain and plasma presented technical difficulties in their collection.…

medicine.medical_specialtyInsecticidesDiazinonHealth Toxicology and MutagenesisMedian lethal doseRetinaToxicologyLethal Dose 50chemistry.chemical_compoundAnguillidaeInternal medicinemedicineAnimalsCholinesterasesTissue DistributionCholinesteraseintegumentary systembiologyPlasma samplesPublic Health Environmental and Occupational HealthBrainGeneral MedicinePesticidebiology.organism_classificationAnguillaPollutionEndocrinologychemistryDiazinonToxicitybiology.proteinSpectrophotometry UltravioletCholinesterase InhibitorsOrganophosphorous pesticideEcotoxicology and environmental safety
researchProduct

Measurable Residual Disease (MRD) Monitoring in Acute Myeloid Leukemia (AML) with t(8;21)(q22;q22.1) RUNX1-RUNX1T1 Identifies Patients at High Risk o…

2019

Background: Acute myeloid leukemia (AML) with t(8;21)(q22;q22.1) resulting in the RUNX1-RUNX1T1 gene fusion is considered favorable in the 2017 genetic risk stratification by the European LeukemiaNet (ELN). After intensive chemotherapy most patients (pts) achieve complete remission (CR), but relapse occurs in about 50% and is associated with poor prognosis. In this AML subgroup monitoring of measurable residual disease (MRD) has been shown to identify pts at higher risk of relapse. Aims: To assess the prognostic impact of MRD monitoring in bone marrow (BM) and peripheral blood (PB) in a large cohort of 155 clinically well-annotated t(8;21)-AML pts enrolled in one of six AMLSG treatment tria…

medicine.medical_specialtyMRD Negativitybusiness.industryImmunologyComplete remissionCell BiologyHematologyBiochemistryPaired samplesInternal medicineRunx1 runx1t1medicineShort latencyGenetic riskRelapse riskT(8;21)(q22;q22)businessBlood
researchProduct

Anteil des frühen systolischen Flussanstiegs am antegrad fließenden Gesamtvolumen bei Phasenkontrast-Flussmessungen in Atemanhaltetechnik

2005

Purpose To evaluate the contribution of early systole for the assessment of antegrade aortic flow volume by breath-hold velocity-encoded magnetic resonance (MR) flow measurements. Materials and methods Expiratory breath-hold fast low-angle shot (FLASH) phase-contrast flow measurements (temporal resolution tRes 61 msec, shared phases) perpendicular to the proximal ascending aorta and short axis true fast imaging with steady-state precession (TrueFISP) cine MR ventriculometry (tRes 34.5 msec) were performed in ten healthy male volunteers on a 1.5 T MR system (Sonata, Siemens Medical Solutions). Antegrade aortic flow volume (AFV) and left ventricular stroke volume (LV-SV) were evaluated using …

medicine.medical_specialtyShort axisVentricular functionmedicine.diagnostic_testbusiness.industryPhase contrast microscopySignificant differenceMagnetic resonance imagingBlood flowlaw.inventionSurgeryVolume (thermodynamics)Flow (mathematics)Paired sampleslawmedicine.arteryAscending aortaLeft ventricular Stroke volumeMedicineRadiology Nuclear Medicine and imagingSystolebusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

A pilot study on non-invasive treatment of migraine: The self-myofascial release

2021

The aims of this paper was to determine the effect of self-myofascial release (SMFR) on postural stability and to analyze if it can influence migraine condition. Twenty-five subjects (age 49.7±12.5) affected by migraine were enrolled. Assessments included a stabilometric analysis in order to evaluate balance and plantar support, with eyes open (OE) and closed (CE); cervical ROM measurement; evaluation of upper limb strength through handgrip. All the analysis were carried out before and after the administration of a single SMFR protocol, using medium density small balls laid in the three most painful trigger points in migraine patients: trapezius, sternocleidomastoids and suboccipital muscle…

medicine.medical_specialtymyofascial release techniques fascia balance cervical ROMlcsh:MedicineArticlelcsh:QM1-69503 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationPaired samplesMedicineOrthopedics and Sports MedicineMolecular BiologyMigrainefasciaBalance (ability)030222 orthopedicsbusiness.industrylcsh:RNon invasivebalancelcsh:Human anatomyCell BiologyMedium densitymedicine.diseasecervical ROMMyofascial releasemyofascial release techniquesmedicine.anatomical_structureMigrainePostural stabilityUpper limbNeurology (clinical)business030217 neurology & neurosurgeryEuropean Journal of Translational Myology
researchProduct

Effect of sample preparation on gel permeation chromatography results of determination of molecular weight of polyethylene obtained with using of zir…

2003

Molecular weights of polyethylene (PE) obtained with using of zirconocene catalyst activated with large excess of methylaluminoxane (MAO) were determined by gel permeation chromatography (GPC) method. It was found that repeatability of the measurements is strongly influenced by MAO remained in PE samples as well as time of sample keeping in the apparatus (dissolution + measurement time) at temp. 142 °C. A method of MAO removing from PE samples, before GPC measurement, based on additional washing of the sample with HF in methanol solution has been proposed. This modification leads to better both authenticity and repeatability of the results. Studies on the influence of time of sample keeping…

polyethylenechemistry.chemical_classificationChromatographyPolymers and PlasticsChemistryGeneral Chemical Engineeringgel permeation chromatographyMethylaluminoxanemethylaluminoxanesamples preparationsPolymerzirconocene catalystPolyethyleneCatalysisGel permeation chromatographychemistry.chemical_compoundMaterials ChemistrySample preparationMethanolAluminoxanePolimery
researchProduct