Search results for "Sanitary engineering"
showing 10 items of 77 documents
Freshwater pearl mussels from northern Sweden serve as long-term, high-resolution stream water isotope recorders
2019
The stable isotope composition of lacustrine sediments is routinely used to infer Late Holocene changes in precipitation over Scandinavia and, ultimately, atmospheric circulation dynamics in the North Atlantic realm. However, such archives only provide a low temporal resolution (ca. 15 years), precluding the ability to identify changes on inter-annual and quasi-decadal timescales. Here, we present a new, high-resolution reconstruction using shells of freshwater pearl mussels, Margaritifera margaritifera, from three streams in northern Sweden. We present seasonally to annually resolved, calendar-aligned stable oxygen and carbon isotope data from 10 specimens, covering the time interval from …
Comparison of measured brightness temperatures from SMOS with modelled ones from ORCHIDEE and H-TESSEL over the Iberian Peninsula
2017
19 pges, 10 figures, 6 tables
Ecohydrology in Mediterranean areas: a numerical model to describe growing seasons out of phase with precipitations
2008
The probabilistic description of soil moisture dynamics is a relatively new topic in hydrology. The most common ecohydrological models start from a stochastic differential equation describing the soil water balance, where the unknown quantity, the soil moisture, depends both on spaces and time. Most of the solutions existing in literature are obtained in a probabilistic framework and under steady-state condition; even if this last condition allows the analytical handling of the problem, it has considerably simplified the same problem by subtracting generalities from it. <br><br> The steady-state hypothesis, appears perfectly applicable in arid and semiarid climatic areas like th…
EAGLE 2006 - Multi-purpose, multi-angle and multi-sensor in-situ and airborne campaigns over grassland and forest
2009
EAGLE2006 – an intensive field campaign for the advances in land surface hydrometeorological processes – was carried out in the Netherlands from 8th to 18th June 2006, involving 16 institutions with in total 67 people from 16 different countries. In addition to the acquisition of multi-angle and multi-sensor satellite data, several airborne instruments – an optical imaging sensor, an imaging microwave radiometer, and a flux airplane – were deployed and extensive ground measurements were conducted over one grassland site at Cabauw and two forest sites at Loobos and Speulderbos in the central part of the Netherlands. The generated data set is both unique and urgently needed for the developmen…
Towards a cyber-physical era: soft computing framework based multi-sensor array for water quality monitoring
2018
Abstract. New concepts and techniques are replacing traditional methods of water quality parameter measurement systems. This paper introduces a cyber-physical system (CPS) approach for water quality assessment in a distribution network. Cyber-physical systems with embedded sensors, processors and actuators can be designed to sense and interact with the water environment. The proposed CPS is comprised of sensing framework integrated with five different water quality parameter sensor nodes and soft computing framework for computational modelling. Soft computing framework utilizes the applications of Python for user interface and fuzzy sciences for decision making. Introduction of multiple sen…
Evaluation of the apparent losses caused by water meter under-registration in intermittent water supply
2009
Apparent losses are usually caused by water theft, billing errors, or revenue meter under-registration. While the first two causes are directly related to water utility management and may be reduced by improving company procedures, water meter inaccuracies are considered to be the most significant and hardest to quantify. Water meter errors are amplified in networks subjected to water scarcity, where users adopt private storage tanks to cope with the intermittent water supply. The aim of this paper is to analyse the role of two variables influencing the apparent losses: water meter age and the private storage tank effect on meter performance. The study was carried out in Palermo (Italy). Th…
Assessment of data and parameter uncertainties in integrated water-quality model
2011
In integrated urban drainage water quality models, due to the fact that integrated approaches are basically a cascade of sub-models (simulating sewer system, wastewater treatment plant and receiving water body), uncertainty produced in one sub-model propagates to the following ones depending on the model structure, the estimation of parameters and the availability and uncertainty of measurements in the different parts of the system. Uncertainty basically propagates throughout a chain of models in which simulation output from upstream models is transferred to the downstream ones as input. The overall uncertainty can differ from the simple sum of uncertainties generated in each sub-model, dep…
Contamination of a hospital plumbing system by persister cells of a copper-tolerant high-risk clone of Pseudomonas aeruginosa
2019
Abstract Background Pseudomonas aeruginosa (PA) is an important opportunistic pathogen that thrives best in the distal elements of plumbing and waste-water systems. Although nosocomial outbreaks of PA have been associated with water sources, the role of the plumbing system of healthcare premises as a reservoir for this pathogen is still unclear. Materials and methods We collected water samples from 12 technical areas, distant from any medical activity, in a teaching hospital in France once a week for 11 weeks. We used a method that resuscitates persister cells because of the nutrient-poor conditions and the presence of inhibitors (e.g. chlorine and copper ions). Briefly, water was sampled i…
Predicting breakthrough of vanadium in fixed-bed absorbent columns with complex groundwater chemistries: A multi-component granular ferric hydroxide−…
2020
Granular ferric hydroxide (GFH) is often used for fixed bed adsorbent (FBA) columns in groundwater purification units around the world to remove arsenate contaminations. Groundwater can contain also other toxic (e.g., antimonite and vanadate) and non-toxic oxo-anions (phosphate and silicic acid) that are known to affect FBA lifetimes. Therefore, understanding the breakthrough of toxic compounds intended for removal by FBA is essential to their design, and is important to predict accurately breakthrough curves (BTCs) for FBAs in waterworks to plan future operating costs. Rapid small-scale column tests (RSCCT) and pilot-scale FBA were used to simulate vanadate BTCs for complex groundwater che…
N-(2-PIRYDYLAMINO) METHYLENEBISPHOSPHONIC ACID AS A SOLE SOURCE OF A FUNGI FUSARIUM STRAINS GROWING
2016
The active substance of new herbicide generation is N-(2-pirydyloamino) methylenobisphosphonic acid. Two strains Fusarium culmorum CB3 and Fusarium oxysporum XVI, isolated from soil treated with examined substance, were chosen to investigation of using it as a sole source of phosphorus, nitrogen or carbon in the concentrations at 1.0 mM. Interactions between the dominating strains of fungi and N-(2-pirydyloamino) methylenobisphosphonic acid, mycelium growth rate, the spore germinate index, the level chemical changes of N-(2-pirydyloamino) methylenobisphosphonic acid and pH were investigated after cultivation in mineral medium and its modifications. The results of growth kinetics of the stud…