Search results for "Scanner"

showing 10 items of 170 documents

Validation of temperature-emissivity separation and split-window methods from TIMS data and ground measurements

2003

Abstract Land surface temperature retrieved with temperature-emissivity separation (TES) and split-window (SW) algorithms from six-channel Thermal Infrared Multispectral Scanner (TIMS) data in the HAPEX-Sahel experiment agreed with contemporaneous ground temperature measurements to within ±1 °C (TES and SW with channels at 10.8 and 11.7 μm, or SW-56). The SW algorithm used with TIMS channels at 8.4 and 8.7 μm (SW-12) underestimated ground temperatures by 2–5 °C. The TES method required atmospheric correction of at-sensor radiances, which was done with local radiosonde data and MODTRAN 4, and an empirical relationship between the spectral range of emissivity and its minimum value. Emissivity…

MODTRANAtmospheric correctionSoil ScienceGeologyVegetationMultispectral Scannerlaw.inventionlawRadianceRange (statistics)EmissivityRadiosondeEnvironmental scienceComputers in Earth SciencesRemote sensingRemote Sensing of Environment
researchProduct

Small animal tumour imaging with MRI and the ECAT EXACT scanner: application of partial volume correction and comparison with microPET data.

2010

Objective Partial volume effects caused by limited spatial resolution of conventional positron emission tomography (PET) scanners result in an underestimation of the activity concentration in small tumours. The aim of the study was to evaluate the feasibility of small animal tumour imaging with the clinical PET scanner ECAT EXACT after partial volume correction based on MRI calculations. The same tumour model was examined additionally with the small animal PET system, microPET focus 120. Methods Before the ECAT EXACT studies recovery coefficients for different sphere volumes were generated with phantom experiments. For the following in-vivo study DS-sarcoma cells were implanted on both hind…

MaleScannerFocus (geometry)Partial volumeImaging phantomRats Sprague-DawleySmall animalNeoplasmsmedicineAnimalsRadiology Nuclear Medicine and imagingGamma countermedicine.diagnostic_testbusiness.industryPhantoms ImagingMagnetic resonance imagingGeneral MedicineMagnetic Resonance ImagingRatsTumor BurdenPositron emission tomographyPositron-Emission TomographyLinear ModelsFeasibility StudiesNuclear medicinebusinessArtifactsNuclear medicine communications
researchProduct

Evaluation of prostate segmentation algorithms for MRI: The PROMISE12 challenge

2014

Contains fulltext : 137969.pdf (Publisher’s version ) (Open Access) Prostate MRI image segmentation has been an area of intense research due to the increased use of MRI as a modality for the clinical workup of prostate cancer. Segmentation is useful for various tasks, e.g. to accurately localize prostate boundaries for radiotherapy or to initialize multi-modal registration algorithms. In the past, it has been difficult for research groups to evaluate prostate segmentation algorithms on multi-center, multi-vendor and multi-protocol data. Especially because we are dealing with MR images, image appearance, resolution and the presence of artifacts are affected by differences in scanners and/or …

MaleScannerObserver (quantum physics)Computer scienceHealth InformaticsSensitivity and SpecificityArticleProstate cancerSegmentationImaging Three-DimensionalRobustness (computer science)Image Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingSegmentationChallengeProtocol (science)Modality (human–computer interaction)Radiological and Ultrasound TechnologyProstateProstatic NeoplasmsReproducibility of ResultsReference Standardsmedicine.diseaseImage EnhancementComputer Graphics and Computer-Aided DesignMagnetic Resonance ImagingActive appearance modelUrological cancers Radboud Institute for Health Sciences [Radboudumc 15]Computer Vision and Pattern RecognitionArtifactsAlgorithmAlgorithmsRare cancers Radboud Institute for Health Sciences [Radboudumc 9]MRI
researchProduct

Radiolucent Carbon Fiber–Reinforced Pedicle Screws for Treatment of Spinal Tumors: Advantages for Radiation Planning and Follow-Up Imaging

2016

Objective Surgical treatment of spinal tumors regularly includes spinal instrumentation with pedicle screws. Most modern pedicle screws are made of titanium alloy, which is associated with artifacts on postoperative imaging such as computed tomography and/or magnetic resonance imaging. These artifacts hamper radiation treatment planning and execution and follow-up imaging. Recently, carbon fiber–reinforced polyetheretherketone (CFRP) implants became available for posterior instrumentation with the aim to reduce imaging artifacts by implants. Methods Patients harboring spinal tumors underwent posterior stabilization using CFRP pedicle screws. Postoperative imaging was evaluated for implant a…

Malemedicine.medical_specialtyTomography Scanners X-Ray ComputedPolymersmedicine.medical_treatmentRadiodensityPolyethylene GlycolsBenzophenones03 medical and health sciences0302 clinical medicineCarbon FiberPedicle ScrewsHounsfield scalemedicineHumansSpinal ChordomaRadiation treatment planningAgedRetrospective StudiesAged 80 and overPostoperative CareSpinal NeoplasmsRadiotherapymedicine.diagnostic_testbusiness.industryMagnetic resonance imagingKetonesMiddle Agedequipment and suppliesmedicine.diseaseMagnetic Resonance ImagingCarbonSurgeryRadiation therapySpinal FusionTreatment Outcome030220 oncology & carcinogenesisFemaleSurgeryNeurology (clinical)RadiologyImplantChordomabusiness030217 neurology & neurosurgeryFollow-Up StudiesWorld Neurosurgery
researchProduct

Transcranial magnetic resonance-guided focused ultrasound surgery at 1.5T: a technical note.

2019

Magnetic resonance-guided focused ultrasound is one of the emerging non-invasive technologies offering both image guidance and thermal monitoring. In recent years transcranial application of this technology is starting to impact heavily the neuroscience field. We present here the imaging protocol and the technological methods successfully used with a transcranial magnetic resonance-guided focused ultrasound system certified for clinical treatments of functional neurological disorders, integrated for the first time with a 1.5T magnetic resonance scanner. Compared to the body radiofrequency coil (the one commonly used with transcranial magnetic resonance-guided focused ultrasound system integ…

Maleminimally invasive surgical procedureComputer sciencebraininterventionalSignal-To-Noise RatioNeurosurgical ProcedureMagnetic Resonance Imaging InterventionalFocused ultrasoundNeurosurgical Procedures030218 nuclear medicine & medical imagingMagnetic resonance guided focused ultrasound surgery03 medical and health sciences0302 clinical medicinemedicinemagnetic resonance imagingHumansGeneral NeuroradiologyRadiology Nuclear Medicine and imagingImage guidanceAgedmedicine.diagnostic_testtomography X-ray computedMagnetic resonance scannerinterventional magnetic resonance imagingSettore MED/37 - NeuroradiologiaMagnetic resonance imagingTechnical noteGeneral MedicineSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)minimally invasive surgical proceduresstereotactic techniqueTreatment Outcomebrain; high-intensity focused ultrasound ablation; interventional magnetic resonance imaging; minimally invasive surgical procedures; stereotactic techniques; aged; female; high-intensity focused ultrasound ablation; humans; male; neurosurgical procedures; signal-to-noise ratio; tomography X-ray computed; treatment outcome; magnetic resonance imaging; interventionalElectromagnetic coilstereotactic techniquesHigh-Intensity Focused Ultrasound AblationFemaleNeurology (clinical)Settore MED/36 - Diagnostica Per Immagini E RadioterapiaTomography X-Ray Computed030217 neurology & neurosurgeryHumanRadiofrequency coilBiomedical engineeringThe neuroradiology journal
researchProduct

Projected fringes for the measurement of large aluminum ingots

2010

The method of projected fringes is applied to the measurement of the surface topography of aluminum ingots with surface areas of several square meters. The measurements are performed inside the casting hall of an aluminum factory. To meet the challenges encountered in such a demanding environment, it is important to keep the equipment as simple and robust as possible. Therefore a method for locating the fringe positions with sub-pixel accuracy without using for example phase shifting techniques is applied. Also the nonlinearity of the phase when using divergent illumination is discussed. The developed measuring system is tested measuring eight different aluminum ingots, and the results agre…

Measurement methodMaterials sciencebusiness.industryApplied MathematicsPhase (waves)chemistry.chemical_elementSquare (algebra)Structured-light 3D scannerOpticschemistryAluminiumCasting (metalworking)Optical metrologybusinessInstrumentationEngineering (miscellaneous)Measurement Science and Technology
researchProduct

Comparison of evapotranspiration estimates by NOAA-AVHRR images and aircraft flux measurements in a semiarid region of Spain.

1998

Abstract This paper is intended to show how to aggregate two different remote-sensing techniques carried out in the framework of the European-Union funded project EFEDA (European Field Experiment in a Desertification-threatened Area). One of these is based on satellite measurements, and the other on aircraft flux measurements. The aim of putting together both methodologies was to determine regional evapotranspiration as a major component of the water balance in Castilla-La Mancha, a semiarid region in southeast Spain. The basis for the satellite approach is using temperature information collected by the Advanced Very High-Resolution Radio- meter (AVHRR) sensor on board the National Oceanic …

Meteorologie en LuchtkwaliteitAerial surveyMeteorology and Air QualityAquatic ScienceMultispectral ScannerAtmosphereWater balanceRange (aeronautics)EvapotranspirationLife ScienceEnvironmental scienceSatelliteSpatial variabilityRemote sensing
researchProduct

Automated segmentation and description of the internal morphology of human permanent teeth by means of micro-CT

2020

High-resolution micro-computed tomography is a powerful tool to analyze and visualize the internal morphology of human permanent teeth. It is increasingly used for investigation of epidemiological questions to provide the dentist with the necessary information required for successful endodontic treatment. The aim of the present paper was to propose an image processing method to automate parts of the work needed to fully describe the internal morphology of human permanent teeth. One hundred and four human teeth were scanned on a high-resolution micro-CT scanner using an automatic specimen changer. Python code in a Jupyter notebook was used to verify and process the scans, prepare the dataset…

Micro-CTScannerComputer scienceInternal tooth morphologyAutomated segmentationRoot canal configurationImage processing610 Medicine & health03 medical and health sciences0302 clinical medicinestomatognathic systemImage Processing Computer-AssistedMedicineHumansComputer visionTooth Root610 Medicine & healthMicro ctGeneral Dentistry030304 developmental biologycomputer.programming_languagePermanent teeth0303 health sciencesbusiness.industryResearchBiomedical image analysisProcess (computing)Reproducibility of ResultsRK1-715030206 dentistryX-Ray MicrotomographyPhysiological foramen geometryPython (programming language)Dentition PermanentAutomated segmentationstomatognathic diseasesDentistryTomographyArtificial intelligenceDental Pulp Cavitybusinesscomputer
researchProduct

Fingerprint image enhancement using directional morphological filter

2005

Fingerprint images quality enhancement is a topic phase to ensure good performance in an automatic fingerprint identification system (AFIS) based on minutiae matching. In this paper a new fingerprint enhancement algorithm based on morphological filter is introduced. The algorithm is based on three steps: directional decomposition, morphological filter and composition. The performance of the proposed approach has been evaluated on two sets of images: the first one is DB3 database from Fingerprint Verification Competition (FVC) and the second one is self collected using an optical scanner

MinutiaeScannerMatching (graph theory)business.industryComputer scienceImage qualityComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONPhase (waves)Fingerprint Verification CompetitionPattern recognitionImage segmentationFingerprintBiometrics | Algorithms | fingerprint orientationArtificial intelligencebusiness
researchProduct

Performance of the AX-PET Demonstrator

2011

The goal of the AX-PET project is to build and test a demonstrator for a high resolution, high sensitivity PET scanner, based on a novel geometrical concept of long axially oriented crystals. The demonstrator comprises two PET modules used in coincidence. The two modules have been constructed and characterized (both individually and in coincidence) in dedicated test setups, with point-like sources. Good performance in terms of energy, spatial and timing resolution have been demonstrated. First measurements with extended phantoms filled with FDG-radiotracers have been recently performed.

Nuclear and High Energy PhysicsEngineeringbusiness.industryPet scannerResolution (electron density)Sensitivity (control systems)businessAtomic and Molecular Physics and OpticsEnergy (signal processing)CoincidenceSimulation
researchProduct