Search results for "Sensitivity"
showing 10 items of 3059 documents
Plain film, CT and MRI sensibility in the evaluation of intraorbital foreign bodies in an in vitro model of the orbit and in pig eyes.
2000
Detection and characterization of intraorbital foreign bodies (IFB) is fundamental in acute trauma setting, preventing inflammatory sequelae or complications related to IFB movements when a MRI study is planned. Papers concerning plain film and CT sensibility in IFB detection show controversial results. For this reason we investigated plain film, CT and MRI sensibility in the evaluation of IFB. For an in vitro model, specimens of dry and fresh wood, glass, iron, plastic and graphite were immersed in animal lard and in a 0.9 % sodium chloride plus 3.5 g/dl human serum albumin solution. Specimens of different size and nature where also implanted into enucleated pig eyes. Air bubbles were intr…
Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.
2016
OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…
Accuracy of automatic airway morphometry in computed tomography-correlation of radiological-pathological findings.
2010
Abstract Objectives Airway morphology shows characteristic changes in different pathologies. This study assesses the accuracy of a current automatic airway assessment technique by correlating CT images of porcine airways to histological slices of the same localization. Materials and methods Four isolated and ventilated porcine lungs were frozen in a liquid nitrogen bath and examined with a CT scanner (MDCT). This technique both preserved normal radiomorphological appearance and made it possible to slice the specimens for histological examination for subsequent correlation. The parameters wall thickness (WT), wall percentage (WP), and total diameter (TD) were assessed by computer-aided measu…
Determination of Nuclear Prostatic Androgen Receptors by FPLC (Fast Protein Liquid Chromatography)
1987
The experimental detection of steroid receptors, quantitative as well as qualitative, has been received with wide-spread interest in the research of the various effects of steroid hormones during recent years. The quantitative measurement of cyto- and karyoplasmatic prostatic androgen receptors, carried out through such methods as the Dextran-Coated-Charcoal-Method (DCC) (Snochowsky et al. 1977), the gradient centrifugation method (Mainwaring and Milroy 1975; Menon et al. 1978) or the Hydroxyl-apatite process (Murthy et al. 1984; Pavlik and Coulson 1976), represent unprecise or complicated analytical processes, which are due to technical factors, such as proteolytical degradation, the time …
Value of routine abdominal and lymph node sonography in the follow-up of breast cancer patients.
1994
Abstract Objective: The aim of this study was to review usefulness and intervals for abdominal sonography during the follow-up of breast cancer patients. Additionally, we assessed the value of regional lymph node sonography in patients with possible locoregional recurrence. Subjects: Retrospectively, 2657 abdominal ultrasound examinations of 414 patients and 299 sonographic examinations of the regional lymph nodes in 227 patients after surgical treatment for breast cancer were evaluated. Results: Follow-up abdominal sonography revealed metastases in 6.8% of patients, and in 1% of examinations. There was no dependence on the initial T- or N-stage. At sonography of the regional lymph nodes in…
Prospective comparison of CT angiography of the legs with intraarterial digital subtraction angiography.
1996
The aim of this study was to determine the accuracy of CT angiography (CTA) with a single spiral acquisition for the diagnosis of arterial stenoses and occlusion in patients with peripheral vascular occlusive disease.In a prospective study, intraarterial digital subtraction angiography and i.v. CTA from the groin to the lower calves were performed on 50 patients with vascular occlusive disease. Maximum-intensity-projection images in multiple views were produced. The accuracy of CTA with and without analysis of the axial scans was determined with digital subtraction angiography as the standard.The sensitivities of CTA were 100% for the diagnosis of femoral artery occlusion, 100% for the dete…
D-dimer testing: advantages and limitations in emergency medicine for managing acute venous thromboembolism
2007
Patients with suspected deep vein thrombosis (DVT) or pulmonary embolism (PE) are frequently admitted to an Emergency Department (ED) for initial evaluation. However, management of patients with suspicion of acute venous thromboembolism (VTE) in this clinical setting can be difficult; in fact symptoms and signs of DVT are non-specific and can be found in a broad spectrum of non-thrombotic disorders. An accurate and timely objective diagnosis is necessary for immediate and correct identification of patients with acute VTE, while avoiding the bleeding risk associated with unnecessary anticoagulant therapy in patients where DVT or PE have been ruled out. The diagnostic approach to patients wit…
Visual acuity and contrast sensitivity screening with a new iPad application
2016
We present a new iPad application (app) for a fast assessment of Visual Acuity (VA) and Contrast Sensitivity (CS) whose reliability and agreement was evaluated versus a commercial screening device (Optec 6500). The measurement of VA was programmed in the app in accordance with the Amblyopia Treatment Study protocol. The CS was measured with sinusoidal gratings of four different spatial frequencies: 3, 6, 12 and 18 cpd at the same contrast values of the Functional Acuity Contrast Test (FACT) included in the Optec 6500. Forty-five healthy subjects with monocular corrected visual acuities better than 0.2 logMAR participated in the agreement study. Bland-Altman analyses were performed to assess…
Impact of the pupil size – central optical zone diameter relationship on visual performance in aspheric multifocal contact lenses
2020
Abstract Purpose To determine the impact of different central optical zone diameters (COZDs), obtained from pupil size, on the visual performance of presbyopic subjects fitted with centre-distance simultaneous-image multifocal contact lenses (SIMCLs). Methods Thirty-two presbyopic volunteers, between 45–58 years of age, participated in this prospective, controlled, double-blind study. Subjects were fitted with 5 centre-distance SIMCLs of variable COZD, determined from the measurement of pupil size under photopic light conditions and corresponding to 60, 70, 80, 90 and 100 % of pupil diameter. Subjects visual performance was evaluated through the measurement of distance, intermediate and nea…
Effect of Varying Levels of Glare on Contrast Sensitivity Measurements of Young Healthy Individuals Under Photopic and Mesopic Vision
2018
Contrast sensitivity (CS), the ability to detect small spatial changes of luminance, is a fundamental aspect of vision. However, while visual acuity is commonly measured in eye clinics, CS is often not assessed. At issue is that tests of CS are not highly standardized in the field and that, in many cases, optotypes used are not sensitive enough to measure graduations of performance and visual abilities within the normal range. Here, in order to develop more sensitive measures of CS, we examined how CS is affected by different combinations of glare and ambient lighting in young healthy participants. We found that low levels of glare have a relatively small impact on vision under both photopi…