Search results for "Senso"

showing 10 items of 4750 documents

Cerebral potentials elicited by mechanical stimuli to the human leg: influence of artifacts

1992

Mechanical stimulation with a reflex hammer was applied to the quadriceps muscle tendon of healthy volunteers and patients. The time-locked electrical signals were recorded from the scalp. In all cases, reproducible potentials could be recorded, with latencies in a range of 20 ms to 100 ms. The potentials recorded in patients under complete spinal anesthesia were similar to those derived before the anesthesia. In brain dead patients who showed absence of median nerve or posterior tibial nerve SEP, reproducible potentials after mechanical stimuli could be recorded as well. The results suggest that the hammer taps lead to mechanical shock waves which are propagated along the body producing ti…

AdultMaleReflex StretchBrain DeathElectroencephalographyAnesthesia SpinalReference ValuesEvoked Potentials SomatosensorymedicineHumansHuman legReflex hammerCerebral CortexAfferent PathwaysLegmedicine.diagnostic_testbusiness.industryMusclesElectroencephalographyGeneral MedicineAnatomyMiddle AgedMedian nerveMedian NerveTendonmedicine.anatomical_structureSpinal CordNeurologySomatosensory evoked potentialScalpReflexFemaleNeurology (clinical)Tibial NervebusinessMechanoreceptorsActa Neurologica Scandinavica
researchProduct

GAA trinucleotide repeat expansion in variant Friedreich's ataxia families.

1997

Phenotypic variants in Friedreich's ataxia include late onset, preservation of the lower limbs tendon reflexes, and slow progression. We describe clinical and electrophysiological features from three families with Friedreichlike phenotypes. Friedreich's ataxia diagnosis was confirmed by finding two allelic expansions of the GAA trinucleotide repeat at the X25 gene. In family 1 both patients had a late-onset phenotype with preservation of knee and ankle jerks, lack of cardiomyopathy, and preserved H reflex. One of them did not have electrophysiologic evidence of sensory axonal neuropathy. Patients from family 2 showed variability in the age of onset, and 2 out of 3 affected children had hype…

AdultMaleReflex Stretchcongenital hereditary and neonatal diseases and abnormalitiesPathologymedicine.medical_specialtySensory axonal neuropathyAtaxiaPhysiologyGenetic LinkageAction PotentialsLate onsetBiologyH-ReflexCellular and Molecular NeuroscienceDegenerative diseaseTrinucleotide RepeatsPhysiology (medical)medicineHumansNeurons AfferentChildAllelesLegGenetic VariationDNACardiomyopathy Hypertrophicmedicine.diseasePedigreePeripheral neuropathyFriedreich AtaxiaReflexDisease ProgressionFemaleNeurology (clinical)medicine.symptomAge of onsetTrinucleotide repeat expansionMusclenerve
researchProduct

An alternative clinical routine for subjective refraction based on power vectors with trial frames.

2016

PURPOSE Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. METHODS An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented …

AdultMaleRefractive errorCorrelation coefficientAdolescentVisual AcuityAstigmatismRefraction Ocular01 natural sciences010309 optics03 medical and health sciencesYoung Adult0302 clinical medicineOptics0103 physical sciencesmedicineHumansPhoropterMathematicsMonocularbusiness.industryOrientation (computer vision)Vision TestsEquipment Designmedicine.diseaseRefractive ErrorsSubjective refractionRefractionSensory SystemsOphthalmologyEyeglasses030221 ophthalmology & optometryFemalebusinessAlgorithmOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation

2003

Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…

AdultMaleRefractive errorVisual acuityRotationgenetic structuresmedicine.medical_treatmentEmmetropiaIntraocular lensPhakic intraocular lensLens Implantation IntraocularmedicineHumansPostoperative PeriodProspective StudiesDioptreLenses Intraocularbusiness.industryAstigmatismEquipment DesignMiddle AgedRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresToric lensOphthalmologyMeridian (perimetry visual field)OptometryFemaleSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Phakic intraocular lenses to correct high myopia

2003

Abstract Purpose: To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. Setting: La Fe University Hospital, Department of Ophthalmology, and the Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods: In this prospective comparative study, a phakic IOL was implanted in 217 highly myopic eyes (118 patients). Fifty-nine eyes received an Adatomed IOL, 21 eyes a Staar IOL, and 137 eyes an Artisan IOL. The mean preoperative spherical equivalent was −15.39 diopters (D) ± 2.83 (SD), −16.00 ± 5.05 D, and −16.17 ± 2.75 D in the Adatomed, Staar, and Artisan groups, respectively. The …

AdultMaleRefractive errormedicine.medical_specialtyIntraocular pressureAnterior subcapsular cataractVisual acuitygenetic structuresAnterior ChamberEye diseasemedicine.medical_treatmentVisual AcuityIntraocular lensRefraction OcularPhakic intraocular lensCataractPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansProspective StudiesIntraocular PressureDioptreLenses Intraocularbusiness.industryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyFeasibility StudiesFemaleSurgerysense organsSafetymedicine.symptombusinessFollow-Up StudiesJournal of Cataract & Refractive Surgery
researchProduct

Long-term results of surgical treatment of high myopia with Worst-Fechner intraocular lenses

1995

Abstract This retrospective study evaluated the results in 90 eyes that had a minus-power anterior chamber intraocular lens implanted to correct high myopia. Preoperative myopia ranged from −7.00 to −24.00 D. Postoperative spherical equivalent was −0.50 D; 80.5% of eyes were within 1.00 D of emmetropia. Two years postoperatively, no cataract formation, retinal detachment, glaucoma, or significant endothelial damage had occurred. We conclude that minus-power lenses can rapidly, safely, and predictably correct high myopia in phakic patients.

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresAnterior ChamberEye diseasemedicine.medical_treatmentVisual AcuityEmmetropiaGlaucomaIntraocular lensProsthesis DesignVision disorderPostoperative ComplicationsOphthalmologyMyopiamedicineHumansLongitudinal StudiesAgedRetrospective StudiesLenses Intraocularbusiness.industryRetinal detachmentRetrospective cohort studyMiddle AgedPrognosismedicine.diseaseeye diseasesSensory SystemsOphthalmologyFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Excimer laser photorefractive keratectomy for high myopia

1995

Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresCorneal Stromamedicine.medical_treatmentEye diseaseVisual AcuityRefraction OcularExcimerPhotorefractive KeratectomyEpitheliumCorneaVision disorderCorneal OpacityOphthalmologyMyopiamedicineHumansIntraocular PressureDioptreExcimer laserbusiness.industryMiddle AgedPrognosismedicine.diseaseAblationeye diseasesSensory SystemsPhotorefractive keratectomyOphthalmologyFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Prevalence of corneal astigmatism before cataract surgery.

2008

To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresmedicine.medical_treatmentEye diseaseIntraocular lensCataract ExtractionAstigmatismCorneal DiseasesVision disorderAge DistributionCorneaOphthalmologymedicinePrevalenceHumansProspective StudiesAgedAged 80 and overbusiness.industryAstigmatismCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureSpainOptometrySurgeryFemalesense organsmedicine.symptombusinessCorneal astigmatismJournal of cataract and refractive surgery
researchProduct

Endothelial study of iris-claw phakic lens: four year follow-up.

1998

Abstract Purpose: To study quantitative and morphometric endothelial changes in phakic eyes implanted with the Worst iris-claw lens to correct high myopia. Setting: Department of Ophthalmology, University Hospital “La Fe”, Valencia, Spain. Material and Methods: This retrospective study involved 111 phakic eyes (73 patients) implanted with the Worst iris-claw lens. Noncontact specular microscopy and computer-assisted analysis was performed preoperatively and 6 months and 1, 2, 3, and 4 years postoperatively. Results: The mean cell loss was 3.85% at 6 months, 6.59% at 1 year, 9.22% at 2 years, 11.68% at 3 years, and 13.42% at 4 years. At 2 years, the hexagonality and coefficient variation in …

AdultMaleReoperationmedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresAnterior Chambermedicine.medical_treatmentEye diseaseCorneal TouchVisual AcuityIrisIntraocular lensCell CountPhakic intraocular lensCorneal DiseasesVision disorderPostoperative ComplicationsLens Implantation IntraocularOphthalmologyCorneaMyopiaMedicineHumansCell SizeRetrospective Studiesbusiness.industryEndothelium CornealMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryOphthalmologymedicine.anatomical_structureSurgeryFemalesense organsmedicine.symptombusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Management of Cochlear Implant Electrode Migration.

2016

The present study reviewed a cochlear implant (CI) patient population after surgery, which received a free-fitting electrode carrier designed for hearing preservation. The aim was to determine the rate of electrode migration of the CI electrodes and present clinical and surgical implications.Retrospective patient review.Tertiary referral university hospital.Two hundred seventy-eight patients implanted uni- or bilaterally with lateral wall electrodes designed for hearing preservation (358 implants). The control group was 323 patients implanted uni- or bilaterally with preformed perimodiolar electrodes (468 implants).Determination of CI electrode migration was conducted according to a clinica…

AdultMaleReoperationmedicine.medical_specialtySpeech perceptionmedicine.medical_treatmentAudiology03 medical and health sciences0302 clinical medicineHearingCochlear implantotorhinolaryngologic diseasesmedicineHumans030223 otorhinolaryngologyCochlear implantationAgedRetrospective StudiesHearing preservationbusiness.industryHearing TestsMiddle AgedCochlear ImplantationSensory SystemsProsthesis FailurePatient populationCochlear ImplantsOtorhinolaryngologySpeech PerceptionFemaleNeurology (clinical)business030217 neurology & neurosurgeryOtologyneurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
researchProduct