Search results for "Senso"
showing 10 items of 4750 documents
Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposes
2013
Accepted version of an article in the journal: Medical Engineering and Physics. Also available from the publisher at: http://dx.doi.org/10.1016/j.medengphy.2013.03.002 In a clinical study, a novel wireless electrocardiogram (ECG) recorder has been evaluated with regard to its ability to perform arrhythmia diagnostics. As the ECG recorder will detect a "non-standard" ECG signal, it has been necessary to compare those signals to "standard" ECG recording signals in order to evaluate the arrhythmia detection ability of the new system. Simultaneous recording of ECG signals from both the new wireless ECG recorder and a conventional Holter recorder was compared by two independent cardiology specia…
Are media reports able to cause somatic symptoms attributed to WiFi radiation? An experimental test of the negative expectation hypothesis
2017
People suffering from idiopathic environmental intolerance attributed to electromagnetic fields (IEI-EMF) experience numerous non-specific symptoms that they attribute to EMF. The cause of this condition remains vague and evidence shows that psychological rather than bioelectromagnetic mechanisms are at work. We hypothesized a role of media reports in the etiology of IEI-EMF and investigated how somatosensory perception is affected. 65 healthy participants were instructed that EMF exposure can lead to enhanced somatosensory perception. Participants were randomly assigned to watch either a television report on adverse health effects of EMF or a neutral report. During the following experiment…
Attentional Focus and Grip Width Influences on Bench Press Resistance Training.
2018
This study evaluated the influence of different attentional foci for varied grip widths in the bench press. Eighteen resistance-trained men were familiarized with the procedure and performed a one-repetition maximum (1RM) test during Session 1. In Session 2, they used three different standardized grip widths (100%, 150%, and 200% of biacromial width distance) in random order at 50% of 1RM while also engaged in three different attention focus conditions (external focus on the bench press, internal focus on pectoralis major muscles, and internal focus on triceps brachii muscles). Surface electromyography (EMG) signals were recorded from the triceps brachii and pectoralis major, and peak EMG …
Vision evaluation in people with Down's syndrome.
1994
We tested the colour vision of 72 people with Down's syndrome using the Ishihara test and an anomaloscope. We found that 13 of the subjects, 6 males and 7 females, had defective colour vision according to Pickford's classification. In monocular vision 10 eyes were protan (five simple, three extreme and two deviant), one eye was simple deuteranomalous and the remaining eyes were normal: in binocular vision four of the subjects were protan (two simple and two deviant), two subjects were deutan (one simple and one deviant) and the rest were normal. Many of our subjects had lens opacities, strabismus, nystagmus, hypermetropia, high myopia and astigmatism, confirming literature reports. The cont…
Femtosecond laser–assisted intrastromal corneal ring segment implantation for high astigmatism correction after penetrating keratoplasty
2013
PURPOSE: To assess the visual and refractive outcomes of femtosecond laser-assisted implanta- tion of Ferrara-type intrastromal corneal ring segments (ICRS) in post-penetrating keratoplasty (PKP) eyes. SETTING: Instituto OftalmolFernOviedo, Spain. DESIGN: Cohort study. METHODS: Patients with previous PKP had ICRS implantation after femtosecond laser tunnel creation. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation. The power vector method was used to analyze refractive errors preoperatively and postoperatively. RESULTS: This study enrolled 32 eyes of 30 patients. The mean UDVA (Snell…
Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lens
2007
To assess visual results after symmetrical bilateral implantation of a distance-dominant bifocal diffractive intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Fifty patients had bilateral implantation of a distance-dominant diffractive bifocal 447D IOL (Acri.Tec GmbH) in a prospective study. Monocular and binocular best corrected distance visual acuities and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 6-month postoperative visit, the mean binocular best corrected distance acuity and…
Allogenic simple limbal epithelial transplantation (alloSLET) from cadaveric donor eyes in patients with persistent corneal epithelial defects
2020
Background/aimTo describe the clinical outcome of allogenic simple limbal epithelial transplantation (alloSLET) utilising tissue from cadaveric donor eyes after failed re-epithelialisation of the corneal surface.MethodsMedical records of 14 eyes from 14 patients treated for persistent corneal epithelial defects with alloSLET were reviewed. The primary outcome measure was complete epithelialisation of the corneal surface. Secondary outcome measures were best corrected visual acuity (BCVA) and postoperative side effects due to surgery or medical therapy.ResultsOf the 14 eyes, 7 received alloSLET only and 7 alloSLET together with penetrating keratoplasty (PK). Thirteen (92.9%) of 14 eyes had a…
Real-time control for transscleral cyclophotocoagulation.
1998
• Background: In transscleral cyclophotocoagulation, the surgeon cannot directly observe the applied laser effects. Overdosage, possibly resulting in unwanted pop effects, or underdosage with no therapeutic effect therefore often occur. • Method and materials: Laser radiation passing through the sclera and ciliary body is partly reflected from the fundus and can be monitored from outside the eye by a detector system. Since all other parameters influencing the intensity of the recorded radiation are constant in time during one laser exposure, the time dependence of this radiation directly reflects the change of transmission of the treated tissue. The laser exposure therefore can be stopped b…
Fixation suppression of optokinetic nystagmus modulates cortical visual-vestibular interaction.
2005
Water activation positron emission tomography and statistical group analysis were used to evaluate differences in activation-deactivation patterns during small-field visual motion stimulation, eliciting rightward optokinetic nystagmus and its fixation suppression in 12 healthy volunteers. Bilateral patterns of activation in the visual cortex, including the motion-sensitive area MT/V5, and deactivations in an assembly of vestibular areas (posterior insula, thalamus, anterior cingulate gyrus) during optokinetic nystagmus was markedly diminished or totally absent during its fixation suppression. This finding agrees with the concept of a reciprocal inhibitory interaction between the visual-opto…
Tactile perceptual processes and their relationship to medically unexplained symptoms and health anxiety
2011
Abstract Objective The Somatic Signal Detection Task (SSDT; Lloyd, Manson, Brown and Poliakoff, 2008) is an innovative paradigm to study perceptual processes related to physical symptoms. It allows examining touch illusions as a laboratory analog of medically unexplained symptoms (MUS) according to the cognitive model of MUS proposed by Brown (2004). The present study compared psychopathologic measures of MUS and health anxiety with SSDT parameters. Furthermore, we aimed to define a reliable measurement of tactile perception threshold. Methods 67 participants of a student population reported whether they detected tactile stimuli at their fingertip which were presented in half of the test tr…