Search results for "Sensor"
showing 10 items of 4594 documents
TRITIUM - A Real-Time Tritium Monitor System for Water Quality Surveillance
2018
In this work the development results of the TRITIUM project is presented. The main objective of the project is the construction of a near real-time monitor for low activity tritium in water, aimed at in-situ surveillance and radiological protection of river water in the vicinity of nuclear power plants. The European Council Directive 2013/51/Euratom requires that the maximum level of tritium in water for human consumption to be lower than 100 Bq/L. Tritium levels in the cooling water of nuclear power plants in normal operation are much higher than the levels caused by the natural and cosmogenic components, and may easily surmount the limit required by the Directive. The current liquid-scint…
The ATLAS Inner Detector commissioning and calibration
2010
The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data-taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and insitu calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energ…
Mini-MALTA: Radiation hard pixel designs for small-electrode monolithic CMOS sensors for the High Luminosity LHC
2020
Journal of Instrumentation 15(02), P02005 (2020). doi:10.1088/1748-0221/15/02/P02005
Acoustic transmitters for underwater neutrino telescopes.
2012
In this paper acoustic transmitters that were developed for use in underwater neutrino telescopes are presented. Firstly, an acoustic transceiver has been developed as part of the acoustic positioning system of neutrino telescopes. These infrastructures are not completely rigid and require a positioning system in order to monitor the position of the optical sensors which move due to sea currents. To guarantee a reliable and versatile system, the transceiver has the requirements of reduced cost, low power consumption, high pressure withstanding (up to 500 bars), high intensity for emission, low intrinsic noise, arbitrary signals for emission and the capacity of acquiring and processing recei…
An Ultrasonic Lens Design Based on Prefractal Structures
2016
The improvement in focusing capabilities of a set of annular scatterers arranged in a fractal geometry is theoretically quantified in this work by means of the finite element method (FEM). Two different arrangements of rigid rings in water are used in the analysis. Thus, both a Fresnel ultrasonic lens and an arrangement of rigid rings based on Cantor prefractals are analyzed. Results show that the focusing capacity of the modified fractal lens is better than the Fresnel lens. This new lens is believed to have potential applications for ultrasonic imaging and medical ultrasound fields.
MALTA: a CMOS pixel sensor with asynchronous readout for the ATLAS High-Luminosity upgrade
2018
Radiation hard silicon sensors are required for the upgrade of the ATLAS tracking detector for the High- Luminosity Large Hadron Collider (HL-LHC) at CERN. A process modification in a standard 0.18 μm CMOS imaging technology combines small, low-capacitance electrodes (∼2 fF for the sensor) with a fully depleted active sensor volume. This results in a radiation hardness promising to meet the requirements of the ATLAS ITk outer pixel layers (1.5 × 1015 neq /cm2 ), and allows to achieve a high signal-to-noise ratio and fast signal response, as required by the HL-LHC 25 ns bunch crossing structure. The radiation hardness of the charge collection to Non-Ionizing Energy Loss (NIEL) has been previ…
Brain electrical source analysis of primary cortical components of the tibial nerve somatosensory evoked potential using regional sources.
1998
Tibial nerve somatosensory evoked potentials (SEPs) show higher amplitudes ipsilateral to the side of stimulation, whereas subdural recordings revealed a source in the foot area of the contralateral hemisphere. We now investigated this paradoxical lateralization by performing a brain electrical source analysis in the P40 time window (34-46 ms). The tibial nerve was stimulated behind the ankle (8 subjects). On each side, 2048 stimuli were applied twice. SEPs were recorded using 32 magnetic resonance imaging (MRI)-verified electrode positions (bandpass 0.5-500 Hz). In each case, the P40 amplitude was higher ipsilaterally (0.45 +/- 0.14 microV) than contralaterally (-0.49 +/- 0.16 microV). The…
Ultrasonic cavity solitons
2007
We report on a new type of localized structure, an ultrasonic cavity soliton, supported by large aspect-ratio acoustic resonators containing viscous media. These states of the acoustic and thermal fields are robust structures, existing whenever a spatially uniform solution and a periodic pattern coexist. Direct proof of their existence is given both through the numerical integration of the model and through the analysis and numerical integration of a generalized Swift-Hohenberg equation, derived from the microscopic equations under conditions close to nascent bistability. An analytical solution for the ultrasonic cavity soliton is given.
The DEPFET based Focal Plane Detectors for MIXS on BepiColombo
2010
X-ray detectors based on arrays of DEPFET macropixels, which consist of a silicon drift detector combined with a detector/amplifier structure DEPFET as readout node, provide a convenient and flexible way to adapt the pixel size of a focal plane detector to the resolving power of any given X-ray optical system. Macropixels combine the traditional benefits of an SDD, like scalability, arbitrary geometry and excellent QE even in the low energy range, with the advantages of DEPFET structures: Charge storage capability, near Fano-limited energy resolution, low power consumption and high speed readout. Being part of the scientific payload of ESA's BepiColombo mission, the MIXS instrument will be …
DEPFET based Instrumentation for the MIXS focal plane on BepiColombo
2009
BepiColombo, ESA's fifth cornerstone mission, is a planetary exploration mission to Mercury. On board of BepiColombo's Mercury Planetary Orbiter (MPO), the MIXS instrument will perform a complete X-ray fluorescence analysis of Mercury's crust with unprecedented spectral and spatial resolution. This is achieved by using a lightweight X-ray mirror system and by using of DEPFET based Macropixel devices as X-ray detectors. DEPFET based Macropixel detectors combine the advantages of the DEPFETs, like flexible readout modes, Fano-limited energy resolution and low power consumption, with the properties of the drift detectors, like arbitrary scalable pixel size and geometry. In addition, the excell…