Search results for "Sensor"
showing 10 items of 4594 documents
When the nose must remain responsive: glutathione conjugation of the mammary pheromone in the newborn rabbit
2014
In insects, xenobiotic-metabolizing enzymes were demonstrated to regulate pheromones inactivation, clearing them from the olfactory periphery and keeping receptors ready for stimulation renewal. Here, we investigate whether similar processes could occur in mammals, focusing on the pheromonal communication between female rabbits and their newborns. Lactating rabbits emit in their milk a volatile aldehyde, 2-methylbut-2-enal, that elicits searching-grasping in neonates; called the mammary pheromone (MP), it is critical for pups which are constrained to find nipples within the 5 min of daily nursing. For newborns, it is thus essential to remain sensitive to this odorant during the whole nursin…
Amygdala
2015
The amygdala is considered a key center in managing emotional information and its dysfunction is at the base of disorders ranging through anxiety, depression, PTSD and autism. However, the amygdala seems heterogeneous both structurally (with pallial and supallial components) and functionally. Thus, whereas cortical and thalamic multimodal sensory inputs enter the basolateral complex, the corticomedial amygdala is dominated by olfactory and vomeronasal inputs. Intrinsic amygdaloid circuitry, connects these two amygdaloid divisions and convey processed information to the main amygdala outputs. The pallial amygdala is the main source for telencephalic outputs to associative cortical areas (e.g…
A Novel Wireless Sensor Network for Electric Power Metering
2013
Wireless sensor network with lightweight and efficient communication infrastructures are today a great interest, both at research and industrial level, as they are the basis for reliable monitoring services. Mesh networks are ideal candidates in this scenario, as they can be very fault-tolerant. After introducing wireless network systems requirements, we show the design of a mesh network routing protocol based on AODV schemas. Its implementation runs on top of low-cost off-the-shelf components, and allowed us to build a custom power meter wireless sensor node.
The Combitube, Self-Inflating Bulb, and Colorimetric Carbon Dioxide Detector to Advance Airway Management in the First Echelon of the Battlefield
2006
Combat lifesavers and Army medics are regular combat soldiers who possess skills that enable them to provide lifesaving assistance to combat casualties. Although their training is not equal to that of paramedics, combat lifesavers and Army medics are trained to assess casualties for airway obstruction, as well as the presence or absence of spontaneous ventilation. They are also familiar with the same basic airway maneuvers that are required for blind insertion of the esophageal-tracheal double-lumen airway (ETDLA). Use of the ETDLA in combination with an esophageal detector device and a colorimetric carbon dioxide detector would require skill similar to that which they already possess in pe…
Optimal placement of quality sensors in water distribution systems
2019
Water supply infrastructures are crucial for the sustainable existence and development of modern cities [1,2]. Water distribution systems (WDSs) are complex structures formed by many elements designed and erected to transport water of sufficient quality from water sources to consumers. The amount of the above elements, which can reach up to tens of thousands of links and junctions, their frequently wide spatial dispersion and the WDS characteristic of being very dynamic structures make the management of real WDSs a complex problem [3-5]. Moreover, although the main objective is to supply water in the quantity and quality required, other requirements are essential, namely maintaining conditi…
Wavefront sensing using a graphical user interface
2015
Contract grant sponsor: Ministerio de Economia y Competividad; Contract grant number: FIS2011-23175; Contract grant sponsor: Generalitat Valenciana; Contract grant number: PROMETEOII/2014/072; Contract grant sponsor: Universitat de Valencia; Contract grant number: UV-SFPIE_DINV14-222801
Dynamic wavefront sensing and correction with low-cost twisted nematic spatial light modulators
2010
Off-the-shelf spatial light modulators (SLMs), like twisted nematic liquid crystal displays (TNLCDs) used in projection systems, show some interesting features such as high spatial resolution, easy handling, wide availability, and low cost. We describe a compact adaptive optical system using just one TNLCD to measure and compensate optical aberrations. The current system operates at a frame rate of the order of 10 Hz with a four-level codification scheme. Wavefront estimation is performed through conventional Hartmann–Shack sensing architecture. The system has proved to work properly with a maximum rms aberration of 0. 76 μm and wavefront gradient of 50 rad/mm at a wavelength of 514 nm. The…
Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs
2014
Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…
In vitro optical performance of nonrotational symmetric and refractive-diffractive aspheric multifocal intraocular lenses: impact of tilt and decentr…
2012
Purpose To evaluate the optical quality of Acrysof Restor SN6AD1 refractive–diffractive +3.00 D and Lentis Mplus LS-312 nonrotational symmetric +3.00 D aspheric multifocal intraocular lenses (IOLs) and analyze the effect of tilt and decentration. Setting University of Valencia, Valencia, and University of Murcia, Murcia, Spain. Design Experimental study. Methods An artificial model eye was used to measure wavefront aberrations of both IOL models. The modulation transfer function (MTF) and point-spread function (PSF) were calculated for a 5.0 mm pupil and under 5 situations: centered, 0.2 mm and 0.4 mm decentered, and 2 degrees and 4 degrees tilted. Results The refractive–diffractive IOL had…
A pilot study on the differences in wavefront aberrations between two ethnic groups of young generally myopic subjects
2008
A comparative population-based cross-sectional study design was used to examine the prevalence of wavefront patterns in two different ethnic groups, and the relationship of these patterns with ocular biometrics and gender. The Shin–Nippon SRW5000 open field autorefractor, the Wavefront Analysis Supported Customized Ablation (WASCA) wavefront analyser and the IOLMaster were used to determine wavefront aberrations, mean spherical equivalent (SE) refractive error and axial length (AL). Seventy-four eyes from 74 young healthy subjects (44 British Asians, 30 Caucasians; 36 men, 38 women; mean age 22.51 ± 3.89 years) with mean SE averaging )1.90 ± 2.76 D (range )10.88 to +2.19 D) were examined. R…