Search results for "Sensor"

showing 10 items of 4594 documents

Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lens

2007

To assess visual results after symmetrical bilateral implantation of a distance-dominant bifocal diffractive intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Fifty patients had bilateral implantation of a distance-dominant diffractive bifocal 447D IOL (Acri.Tec GmbH) in a prospective study. Monocular and binocular best corrected distance visual acuities and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 6-month postoperative visit, the mean binocular best corrected distance acuity and…

AdultMalemedicine.medical_specialtygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensContrast SensitivityNear acuityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularDepth PerceptionVision BinocularPhacoemulsificationMonocularbusiness.industryDistance PerceptionPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyPostoperative visitOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Allogenic simple limbal epithelial transplantation (alloSLET) from cadaveric donor eyes in patients with persistent corneal epithelial defects

2020

Background/aimTo describe the clinical outcome of allogenic simple limbal epithelial transplantation (alloSLET) utilising tissue from cadaveric donor eyes after failed re-epithelialisation of the corneal surface.MethodsMedical records of 14 eyes from 14 patients treated for persistent corneal epithelial defects with alloSLET were reviewed. The primary outcome measure was complete epithelialisation of the corneal surface. Secondary outcome measures were best corrected visual acuity (BCVA) and postoperative side effects due to surgery or medical therapy.ResultsOf the 14 eyes, 7 received alloSLET only and 7 alloSLET together with penetrating keratoplasty (PK). Thirteen (92.9%) of 14 eyes had a…

AdultMalemedicine.medical_specialtygenetic structuresPrednisoloneVisual AcuityLimbus CorneaeCorneal DiseasesCellular and Molecular NeuroscienceRe-EpithelializationCorneaOphthalmologyCadaverHumansMedicineEffective treatmentIn patientAgedRetrospective StudiesCorneal epitheliumAged 80 and overbusiness.industryEpithelium CornealCadaveric donorMiddle AgedMycophenolic AcidAllograftsTissue Donorseye diseasesSensory SystemsTransplantationOphthalmologyTreatment Outcomemedicine.anatomical_structureFemalesense organsbusinessBandage contact lensOcular surfaceImmunosuppressive AgentsBritish Journal of Ophthalmology
researchProduct

Real-time control for transscleral cyclophotocoagulation.

1998

• Background: In transscleral cyclophotocoagulation, the surgeon cannot directly observe the applied laser effects. Overdosage, possibly resulting in unwanted pop effects, or underdosage with no therapeutic effect therefore often occur. • Method and materials: Laser radiation passing through the sclera and ciliary body is partly reflected from the fundus and can be monitored from outside the eye by a detector system. Since all other parameters influencing the intensity of the recorded radiation are constant in time during one laser exposure, the time dependence of this radiation directly reflects the change of transmission of the treated tissue. The laser exposure therefore can be stopped b…

AdultMalemedicine.medical_specialtygenetic structuresSwineGlaucomaFundus (eye)Signallaw.inventionCellular and Molecular NeuroscienceCiliary bodyPostoperative ComplicationslawTransmission curveOphthalmologymedicineCadaverAnimalsHumansAgedLaser Coagulationbusiness.industryCiliary BodyGlaucomaMiddle AgedLasermedicine.diseaseeye diseasesSensory SystemsIntensity (physics)ScleraOphthalmologymedicine.anatomical_structureTreatment OutcomeFemalesense organsSafetybusinessScleraGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
researchProduct

Fixation suppression of optokinetic nystagmus modulates cortical visual-vestibular interaction.

2005

Water activation positron emission tomography and statistical group analysis were used to evaluate differences in activation-deactivation patterns during small-field visual motion stimulation, eliciting rightward optokinetic nystagmus and its fixation suppression in 12 healthy volunteers. Bilateral patterns of activation in the visual cortex, including the motion-sensitive area MT/V5, and deactivations in an assembly of vestibular areas (posterior insula, thalamus, anterior cingulate gyrus) during optokinetic nystagmus was markedly diminished or totally absent during its fixation suppression. This finding agrees with the concept of a reciprocal inhibitory interaction between the visual-opto…

AdultMalemedicine.medical_specialtygenetic structuresThalamusSensory systemStimulationFixation OcularAudiologymedicineHumansNystagmus OptokineticAgedVisual CortexVestibular systemBrain MappingGeneral NeuroscienceOptokinetic reflexReflex Vestibulo-OcularMiddle Agedeye diseasesVisual cortexmedicine.anatomical_structureCerebrovascular CirculationPositron-Emission TomographyFixation (visual)Visual PerceptionPsychologyNeuroscienceInsulaPhotic StimulationNeuroreport
researchProduct

Tactile perceptual processes and their relationship to medically unexplained symptoms and health anxiety

2011

Abstract Objective The Somatic Signal Detection Task (SSDT; Lloyd, Manson, Brown and Poliakoff, 2008) is an innovative paradigm to study perceptual processes related to physical symptoms. It allows examining touch illusions as a laboratory analog of medically unexplained symptoms (MUS) according to the cognitive model of MUS proposed by Brown (2004). The present study compared psychopathologic measures of MUS and health anxiety with SSDT parameters. Furthermore, we aimed to define a reliable measurement of tactile perception threshold. Methods 67 participants of a student population reported whether they detected tactile stimuli at their fingertip which were presented in half of the test tr…

AdultMalemedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectIllusionAnxietyAudiologyStimulus (physiology)Developmental psychologySensory thresholdPerceptionmedicineHumansSomatoform Disordersmedia_commonTactile perceptionResponse biasPsychiatry and Mental healthClinical PsychologyTouch PerceptionTouchSensory ThresholdsTouch PerceptionAnxietyFemalemedicine.symptomPsychologyJournal of Psychosomatic Research
researchProduct

Long-term sensorimotor and therapeutical effects of a mild regime of prism adaptation in spatial neglect

2015

International audience; Spatial neglect (SN) is commonly associated with poor functional outcome. Adaptation to a rightward optical deviation of vision has been shown to benefit to SN rehabilitation. The neurophysiological foundations and the optimal modalities of prism adaptation (PA) therapy however remain to be validated. This study is aimed at exploring the long-term sensory-motor, cognitive and functional effects produced by weekly PA sessions over a period of four weeks. A double-blind, monocentric randomized and controlled trial (RCT) was carried out. Twenty patients with left SN secondary to stroke were included, 10 in the “prism” group and 10 in the “control” group. The sensory-mot…

AdultMalemedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentNeglectlaw.inventionPerceptual DisordersDouble blindPhysical medicine and rehabilitationDouble-Blind MethodRandomized controlled trialFeedback SensorylawmedicineHumansAttentionOrthopedics and Sports MedicineStrokeHemineglectAgedmedia_commonSpatial neglectRehabilitationRehabilitationCognitionMiddle Agedmedicine.diseaseAdaptation PhysiologicalFunctional Independence MeasureStrokeTreatment OutcomePrism adaptationSpace Perception[ SDV.NEU ] Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]Egocentric referenceVisual PerceptionPhysical therapyFemale[SDV.NEU]Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]Bottom-upPsychologyPrism adaptationPsychomotor PerformanceRCTAnnals of Physical and Rehabilitation Medicine
researchProduct

Effect of 3rd-order aberrations on human vision

2007

To investigate the effect of 3rd-order aberrations on human vision.Grupo de Ciencias de la Visión, University of Murcia, Murcia, Spain.The 3rd-order aberrations coma and trefoil were induced with purpose-designed soft contact lenses, 3 inducing coma (low [0.05 microm], medium [0.13 microm], high [1.03 microm]) and 3 inducing trefoil (low [0.07 microm], medium [0.17 microm], high [0.96 microm]). Monocular high-contrast (HCVA) and low-contrast (LCVA) visual acuities and contrast sensitivity were measured in 11 subjects wearing contact lenses with a 5.0 mm artificial pupil.The reduction in HCVA and LCVA was statistically significant only for the highest coma and trefoil values (P.0001). For co…

AdultMalemedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentVision DisordersVisual AcuityComa (optics)Models Biologicaldigestive systemContrast SensitivityOcular physiologyOpticsOphthalmologyRefractive surgeryHumansMedicineContrast (vision)TrefoilVision Ocularmedia_commonbusiness.industryContact Lenses HydrophilicRefractive ErrorsSensory SystemsInduced comaOphthalmologyFemaleSurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Long-term follow-up of a multifocal apodized diffractive intraocular lens after cataract surgery.

2007

Purpose To report the long-term performance of the AcrySof ReSTOR SA60D3 intraocular lens (IOL) after cataract surgery. Setting University Hospital Maastricht, Maastricht, The Netherlands. Methods This prospective clinical trial comprised 44 eyes (22 consecutive patients) having cataract surgery with implantation of the ReSTOR IOL. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected near visual acuity, best distance-corrected near visual acuity, spectacle dependence, undesired visual symptoms, patient satisfaction, and incidence of posterior capsule opacification were analyzed 6 months and 3 years postoperatively. Results The mean u…

AdultMalemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentEye diseaseAcrylic ResinsVisual AcuityIntraocular lensRefraction OcularCataractContrast SensitivityPatient satisfactionLens Implantation IntraocularOphthalmologySurveys and QuestionnairesmedicineHumansProspective StudiesProspective cohort studyAgedAged 80 and overLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)PhacoemulsificationCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomePatient SatisfactionCapsulotomyQuality of LifeOptometrySurgeryFemalesense organsbusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Myxoma of the orbit: a clinicopathologic report.

1990

A 27-year-old white man developed proptosis of his left eye over a period of 2 years. It was associated with vertical diplopia and displacement of the left globe down and laterally. Ultrasonography showed a cystic mass in the superior orbital region. Computed tomography (CT) demonstrated a solid, well-defined lesion behind the globe displacing the optic nerve medially. A transfrontal craniotomy revealed a nodular mass in the posterior and superior orbit, which extended anteriorly up to the globe. Histopathology, immunohistochemistry, and transmission electron microscopy proved the tumor to be a myxoma.

AdultMalemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentEye diseaseLesionCellular and Molecular NeurosciencemedicineDiplopiaExophthalmosHumansCraniotomyUltrasonographyDiplopiabusiness.industryMyxomaAnatomymedicine.diseaseeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureOptic nerveOrbital NeoplasmsHistopathologysense organsmedicine.symptombusinessTomography X-Ray ComputedMyxomaOrbit (anatomy)Follow-Up StudiesGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
researchProduct

Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens

2005

Purpose To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Twenty-two myopic eyes and 9 hyperopic eyes were included in the study. The mean age of the 2 groups was 34 years and 40 years, respectively. The scotopic pupil size was measured with a handheld infrared pupillometer (Colvard, Oasis Medical) before and 6 months after implantation of the TPIOL. All examinations were performed under scotopic conditions after 2 minutes of dark adaptation with the fellow eye covered. Intraindi…

AdultMalemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentIrisMagnificationIntraocular lensAstigmatismProsthesis DesignPhakic intraocular lensPupilLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaMydriasismedicineHumansIris (anatomy)Lenses Intraocularbusiness.industrySuture TechniquesAstigmatismPupilMiddle Agedmedicine.diseaseeye diseasesSensory SystemsToric lensOphthalmologyHyperopiamedicine.anatomical_structureOptometryFemaleSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct