Search results for "Sensory Systems"
showing 10 items of 793 documents
DaVinci's Mona Lisa entering the next dimension.
2013
For several of Leonardo da Vinci's paintings, such as The Virgin and Child with St Anne or the Mona Lisa, there exist copies produced by his own studio. In case of the Mona Lisa, a quite exceptional, rediscovered studio copy was presented to the public in 2012 by the Prado Museum in Madrid. Not only does it mirror its famous counterpart superficially; it also features the very same corrections to the lower layers, which indicates that da Vinci and the ‘copyist’ must have elaborated their panels simultaneously. On the basis of subjective (thirty-two participants estimated painter-model constellations) as well as objective data (analysis of trajectories between landmarks of both paintings), …
Monocular Versus Binocular Calibrations in Evaluating Fixation Disparity With a Video-Based Eye-Tracker
2015
When measuring fixation disparity (an oculomotor vergence error), the question arises as to whether a monocular or binocular calibration is more precise and physiologically more appropriate. In monocular calibrations, a single eye fixates on a calibration target that is taken as having been projected onto the center of the fovea; the corresponding vergence state represents the heterophoria (the resting vergence position), which has no effect on the calibration procedure. In binocular calibrations, a vergence error may be present and may affect the subsequent measurement of the fixation disparity during binocular recordings. This study includes a test of the precision of both monocular and …
Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creatio…
2010
Purpose To compute and compare visual acuity, refractive outcomes, and anterior corneal aberration changes after myopic laser in situ keratomileusis (LASIK) with flap creation by a mechanical microkeratome and by a femtosecond laser. Setting Private practice refractive surgery center, Valencia, Spain. Design Comparative case series. Methods Patients were assigned to have LASIK flap creation with a mechanical microkeratome (Carriazo-Barraquer) or a femtosecond laser (IntraLase). The Visx S2 excimer laser was used for myopic ablation in all cases. Main outcome measures included uncorrected and corrected distance visual acuities and the defocus equivalent. Higher-order aberrations (HOAs) were …
Visual performance of two simultaneous vision multifocal contact lenses
2012
Purpose To evaluate and compare the visual performance of two simultaneous vision multifocal contact lenses (CLs). Methods In this cross-over study design 20 presbyopic subjects were fitted with two different simultaneous vision multifocal CLs (the PureVision Multifocal Low Add and Acuvue Oasys for Presbyopia) in random order. After 1 month, binocular distance visual acuity (BDVA) under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions, binocular near visual acuity (BNVA), binocular distance contrast sensitivity function (CSF) under photopic and mesopic conditions, binocular near CSF and defocus curve were measured. Subjects were then refitted with the alternative correction and the proc…
Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system.
2007
To assess the quality of vision in patients who had implantation of asymmetric Acri. Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The study comprised 343 consecutive patients who had bilateral implantation of the Acri. Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were…
Quantifying the Wollaston Illusion
2020
In the early 19th century, William H. Wollaston impressed the Royal Society of London with engravings of portraits. He manipulated facial features, such as the nose, and thereby dramatically changed the perceived gaze direction, although the eye region with iris and eye socket had remained unaltered. This Wollaston illusion has been replicated numerous times but never with the original stimuli. We took the eyes (pupil and iris) from Wollaston’s most prominent engraving and measured their perceived gaze direction in an analog fashion. We then systematically added facial features (eye socket, eyebrows, nose, skull, and hair). These features had the power to divert perceived gaze direction by…
The Auditory Kuleshov Effect: Multisensory Integration in Movie Editing
2016
Almost a hundred years ago, the Russian filmmaker Lev Kuleshov conducted his now famous editing experiment in which different objects were added to a given film scene featuring a neutral face. It is said that the audience interpreted the unchanged facial expression as a function of the added object (e.g., an added soup made the face express hunger). This interaction effect has been dubbed “Kuleshov effect.” In the current study, we explored the role of sound in the evaluation of facial expressions in films. Thirty participants watched different clips of faces that were intercut with neutral scenes, featuring either happy music, sad music, or no music at all. This was crossed with the facia…
Allocentric time-to-contact and the devastating effect of perspective
2014
AbstractWith regard to impending object–object collisions, observers may use different sources of information to judge time to contact (tC). We introduced changes of the observer’s vantage point to test among three sets of hypotheses: (1) Observers may use a distance-divided-by-velocity algorithm or, alternatively, elaborated τ-formulae, all of which give exact tC information; (2) observers may use simple τ-formulae (i.e., formulae of the type: visual angle divided by its own first temporal derivative); (3) observers may capitalize on non-τ variables. Hypotheses (2) and (3) imply specific patterns of errors. We presented animated, impending collisions between a moving object and a stationar…
The big picture: effects of surround on immersion and size perception.
2014
Despite the fear of the entertainment industry that illegal downloads of films might ruin their business, going to the movies continues to be a popular leisure activity. One reason why people prefer to watch movies in cinemas may be the surround of the movie screen or its physically huge size. To disentangle the factors that might contribute to the size impression, we tested several measures of subjective size and immersion in different viewing environments. For this purpose we built a model cinema that provided visual angle information comparable with that of a real cinema. Subjects watched identical movie clips in a real cinema, a model cinema, and on a display monitor in isolation. Wher…
Timing flickers across sensory modalities
2009
In tasks requiring a comparison of the duration of a reference and a test visual cue, the spatial position of test cue is likely to be implicitly coded, providing a form of a congruency effect or introducing a response bias according to the environmental scale or its vectorial reference. The precise mechanism generating these perceptual shifts in subjective duration is not understood, although several studies suggest that spatial attentional factors may play a critical role. Here we use a duration comparison task within and across sensory modalities to examine if temporal performance is also modulated when people are exposed to spatial distractors involving different sensory modalities. Di…