Search results for "Sensory Systems"
showing 10 items of 793 documents
Vascular modifications within a choroidal osteoma
1993
We report a case of choroidal osteoma followed-up for 7 years. During this lapse of time the choroidal osteoma showed slight enlargement, development of subretinal hemorrhage and modifications of intratumoral vascularization. Some large intratumoral vessels visible at first examination disappeared at follow-up, while other vessels not observed before developed. The changes in the vascularization of the choroidal osteoma denote profound dynamics in the processes of osseous rearrangement of the tumor.
Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.
2005
To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany.In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometri…
Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes.
2004
Abstract Purpose: To evaluate the change in contrast sensitivity after implantation of the Verisyse toric phakic intraocular lens (IOL) (AMO) for the correction of myopia with astigmatism. Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods: Eighteen eyes had implantation of an iris-supported toric phakic IOL to correct myopia with astigmatism. The mean preoperative spherical equivalent was −12.65 diopters ± 3.6 (SD). The contrast sensitivity with best spectacle correction was determined before surgery and 3 months after surgery using the CSV-1000 HGT instrument (Vector Vision Inc.). Results: Three months after IOL implantation, the mean contrast sen…
Evaluation of the postural stability of elderly persons using time domain signal analysis
2012
A force platform is widely used in the evaluation of postural stability in man. Although an abundance of parameters are typically retrieved from force platform data, no uniform analysis of the data has been carried out. In general, the signal analysis does not analyze the underlying postural event, i.e., whether the signal consists of several small corrections or large excursions. In the present work, we studied the postural stability of 4589 elderly persons from Iceland on a force platform under visual and non-visual conditions during stance on a solid surface. We analyzed the internal relationship between frequently used time domain variables. In addition, we conducted a factor analysis u…
Biogenic Amines Modulate Olfactory Receptor Neurons Firing Activity in Mamestra brassicae
2001
The modulatory effects of the biogenic amines octopamine and serotonin on pheromonal receptor neurons of Mamestra brassicae were investigated. The responses to sex pheromone components of two cells types (A and B) in single male long sensilla trichodea were monitored. Cell types A and B do not respond to the same compound. The response of type A to a pulse of the major sex pheromone component increased 5 min after octopamine injection. Responses of type B to other odorants increased after 30 min. In the absence of any pheromone stimulation the background firing activity of type A increased following octopamine injection. This background activity was used to evaluate the kinetics of octopami…
Successful subretinal delivery and monitoring of MicroBeads in mice
2013
BACKGROUND: To monitor viability of implanted genetically engineered and microencapsulated human stem cells (MicroBeads) in the mouse eye, and to study the impact of the beads and/or xenogenic cells on retinal integrity. METHODOLOGY/PRINCIPAL FINDINGS: MicroBeads were implanted into the subretinal space of SV126 wild type mice using an ab externo approach. Viability of microencapsulated cells was monitored by noninvasive retinal imaging (Spectralis™ HRA+OCT). Retinal integrity was also assessed with retinal imaging and upon the end of the study by light and electron microscopy. The implanted GFP-marked cells encapsulated in subretinal MicroBeads remained viable over a period of up to 4 mont…
An odor timer in milk? Synchrony in the odor of milk effluvium and neonatal chemosensation in the mouse.
2012
International audience; Mammalian newborns exhibit avid responsiveness to odor compounds emanating from conspecific milk. Milk is however developmentally heterogeneous in composition as a function of both evolved constraints and offspring demand. The present study aimed to verify whether milk odor attractivity for neonates is equally distributed along lactation in Mus musculus (Balb-c strain). Therefore, we exposed pups varying in age to milk samples collected from females in different lactational stages. The pups were assayed at postnatal days 2 (P2), 6 (P6) and 15 (P15) in a series of paired-choice tests opposing either murine milk and a blank (water), or two samples of milk collected in …
Image quality with multifocal intraocular lenses and the effect of pupil size
2007
Purpose To analyze the image quality with a refractive and 2 hybrid refractive–diffractive multifocal intraocular lenses (IOLs) in vitro to determine the IOL modulation transfer function (MTF) following the EN-ISO international standard for distance and near vision and to study the IOLs' behavior with different pupil sizes. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods This study evaluated 4 IOLs: the hybrid refractive–diffractive AcrySof ReSTOR SN60D3 (Alcon) and Tecnis ZM900 (AMO), the refractive ReZoom NXG (AMO), and the monofocal AcrySof SN60WF (Alcon). The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Sci…
Uveal effusion syndrome complicated by anterior ischemic optic neuropathy
1995
We report on a case of idiopathic uveal effusion syndrome complicated by AION. To our knowledge such an association hasn't been previously described. We suggest that scleral thickening caused obstruction of vortex veins followed by uveal effusion and compression of posterior ciliary arteries within their intrascleral tract, leading to AION. Nevertheless it can't be excluded that AION was the result of mechanical compression on ciliary vessels of optic disc by choroidal detachment. © 1996, Kluwer Academic Publishers. All rights reserved.
Judging body weight from faces: the height-weight illusion.
2012
Being able to exploit features of the human face to predict health and fitness can serve as an evolutionary advantage. Surface features such as facial symmetry, averageness, and skin colour are known to influence attractiveness. We sought to determine whether observers are able to extract more complex features, namely body weight. If possible, it could be used as a predictor for health and fitness. For instance, facial adiposity could be taken to indicate a cardiovascular challenge or proneness to infections. Observers seem to be able to glean body weight information from frontal views of a face. Is weight estimation robust across different viewing angles? We showed that participants stron…