Search results for "Sensory system"
showing 10 items of 1266 documents
Sequential grouping modulates the effect of non-simultaneous masking on auditory intensity resolution.
2012
The presence of non-simultaneous maskers can result in strong impairment in auditory intensity resolution relative to a condition without maskers, and causes a complex pattern of effects that is difficult to explain on the basis of peripheral processing. We suggest that the failure of selective attention to the target tones is a useful framework for understanding these effects. Two experiments tested the hypothesis that the sequential grouping of the targets and the maskers into separate auditory objects facilitates selective attention and therefore reduces the masker-induced impairment in intensity resolution. In Experiment 1, a condition favoring the processing of the maskers and the targ…
An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers
2021
This study aims to assess the performance of an analysis method to measure in vivo the movement speed of tear film particles post-blink as a measure of tear film spreading. Ocular surface parameter...
Mass spectroscopic analysis of excimer laser ablated material from human corneal tissue.
1988
The clinical feasibility of photorefractive keratectomy depends on the surface structure of the ablated cornea. Two factors that influence the remodeled surface are the homogeneity of the energy distribution and the properties of the laser source (energy and wavelength). Currently, the homogeneity of the beam is difficult to control. The second factor, laser source properties, was the focus of this study. We investigated the effect of laser wavelength and energy by analyzing the reaction products of photoablation. We monitored the fragments produced by UV-laser ablation of human corneas using mass spectroscopy in the range of 0 to 100 atomic mass units. At 248 nm (KrF), average photon energ…
Incidence of posterior vitreous detachment after cataract surgery
2009
Purpose To report the incidence of posterior vitreous detachment (PVD) after uneventful state-of-the-art small-incision phacoemulsification with implantation of a posterior chamber intraocular lens (PC IOL). Setting Department of Ophthalmology, Ludwigshafen Hospital, Ludwigshafen, Germany. Methods This prospective study evaluated the vitreous status of eyes by biomicroscopic examination, indirect binocular ophthalmoscopy, and B-scan ultrasonography before planned cataract surgery. Patients with the posterior vitreous attached were included for follow-up and examined 1 week, 1 month, and 1 year after uneventful phacoemulsification with PC IOL implantation. The preoperative prevalence and pos…
Visual cortex hyperexcitability in migraine in response to sound-induced flash illusions
2015
Objective: Sound-induced flash illusions depend on visual cortical excitability. In this study, we explored whether sound-induced flash illusions are perceived differently in migraine, a condition associated with pathologic cortical hyperexcitability. Methods: Sound-induced flash illusions were examined in 59 migraine patients (mean age = 32 ± 16 years; 36 females), 32 without aura and 27 with aura, and in 24 healthy controls (mean age = 42 ± 17 years; 16 females). Patients were studied during attacks and interictally. Visual stimuli (flashes) accompanied by sounds (beeps) were presented in different combinations: a single flash with multiple beeps was given to induce the perception of mult…
Plasticity of brain wave network interactions and evolution across physiologic states
2015
Neural plasticity transcends a range of spatio-temporal scales and serves as the basis of various brain activities and physiologic functions. At the microscopic level, it enables the emergence of brain waves with complex temporal dynamics. At the macroscopic level, presence and dominance of specific brain waves is associated with important brain functions. The role of neural plasticity at different levels in generating distinct brain rhythms and how brain rhythms communicate with each other across brain areas to generate physiologic states and functions remains not understood. Here we perform an empirical exploration of neural plasticity at the level of brain wave network interactions repre…
Differences in psychomotor reaction time in male monozygotic twins discordant for lifetime cigarette smoking.
1996
The effects of long-term cigarette smoking on psychomotor reaction time were investigated among 8 pairs of monozygotic male twins highly discordant for lifetime smoking (means 32.4 versus 0.6 pack-years). The men had no diagnosed cardiovascular disease or other major diseases, musculoskeletal complaints, or vision problems that might interfere with reaction time testing. The twins had similar education, work, and exercise histories; alcohol and coffee consumption and exposure to solvents were examined as possible confounds. Direct comparison of cotwins also controlled for age, genetics, and possible early environmental factors. Simple and choice reaction time were measured in the dominant h…
Interoceptive and multimodal functions of the operculo-insular cortex: tactile, nociceptive and vestibular representations.
2013
The operculo-insular cortex has been termed the 'homeostatic control center' or 'general magnitude estimator' of the human mind. In this study, somatosensory, nociceptive and caloric vestibular stimuli were applied to reveal, whether there are mainly common, or possibly specific regions activated by one modality alone and whether lateralization effects, time pattern differences or influences of the aversive nature of the stimuli could be observed. Activation of the dorsal posterior insula was caused by all stimuli alike thus terming this area multimodal. Early phases of the noxious heat and caloric vestibular stimulation led to responses in the anterior insula. Using conjunction analyses we…
Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering
2013
Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …
Convergence of nociceptive and non-nociceptive input onto the medullary dorsal horn in man
1998
Referred pain arising in orofacial pain states is probably due to convergence of different somatosensory input onto the medullary dorsal horn (MDH). To examine convergence between nociceptive and non-nociceptive input onto the MDH, the blink reflex (BR) was applied. R1- and R2-components can be evoked by innocuous stimuli, but only the R2 is elicited by painful heat. The BR was elicited by innocuous electrical stimuli applied to the supraorbital nerve. A conditioning painful heat pulse which did not evoke any BR was homotopically applied to the left forehead preceding the electrical stimulus by 75 ms. While R1 remained unchanged, the R2 was facilitated by about 30%. This study demonstrates …