Search results for "Sensory system"
showing 10 items of 1266 documents
Influence of articulation rate on two memory tasks in young and older adults.
2008
This study investigated the relation between phonological loop functioning and age. Phonological loop is a time-based subsystem of the Working Memory Model of Baddeley and Wilson, which uses rehearsal of information as an active process to avoid phonological decay. Performance differences were examined between young and older adults in two speech-based memory tasks, such as the immediate serial recall of words and the Digit Ordering Task. Analysis showed that performance on both tasks was lower for the older group. Articulation rate was also measured to test the hypothesis that the impairment of some cognitive functions in adults can be associated to their slowness or the greater time need…
An alternative clinical routine for subjective refraction based on power vectors with trial frames.
2016
PURPOSE Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. METHODS An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented …
Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation
2003
Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…
Phakic intraocular lenses to correct high myopia
2003
Abstract Purpose: To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. Setting: La Fe University Hospital, Department of Ophthalmology, and the Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods: In this prospective comparative study, a phakic IOL was implanted in 217 highly myopic eyes (118 patients). Fifty-nine eyes received an Adatomed IOL, 21 eyes a Staar IOL, and 137 eyes an Artisan IOL. The mean preoperative spherical equivalent was −15.39 diopters (D) ± 2.83 (SD), −16.00 ± 5.05 D, and −16.17 ± 2.75 D in the Adatomed, Staar, and Artisan groups, respectively. The …
Long-term results of surgical treatment of high myopia with Worst-Fechner intraocular lenses
1995
Abstract This retrospective study evaluated the results in 90 eyes that had a minus-power anterior chamber intraocular lens implanted to correct high myopia. Preoperative myopia ranged from −7.00 to −24.00 D. Postoperative spherical equivalent was −0.50 D; 80.5% of eyes were within 1.00 D of emmetropia. Two years postoperatively, no cataract formation, retinal detachment, glaucoma, or significant endothelial damage had occurred. We conclude that minus-power lenses can rapidly, safely, and predictably correct high myopia in phakic patients.
Excimer laser photorefractive keratectomy for high myopia
1995
Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…
Prevalence of corneal astigmatism before cataract surgery.
2008
To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…
Endothelial study of iris-claw phakic lens: four year follow-up.
1998
Abstract Purpose: To study quantitative and morphometric endothelial changes in phakic eyes implanted with the Worst iris-claw lens to correct high myopia. Setting: Department of Ophthalmology, University Hospital “La Fe”, Valencia, Spain. Material and Methods: This retrospective study involved 111 phakic eyes (73 patients) implanted with the Worst iris-claw lens. Noncontact specular microscopy and computer-assisted analysis was performed preoperatively and 6 months and 1, 2, 3, and 4 years postoperatively. Results: The mean cell loss was 3.85% at 6 months, 6.59% at 1 year, 9.22% at 2 years, 11.68% at 3 years, and 13.42% at 4 years. At 2 years, the hexagonality and coefficient variation in …
Management of Cochlear Implant Electrode Migration.
2016
The present study reviewed a cochlear implant (CI) patient population after surgery, which received a free-fitting electrode carrier designed for hearing preservation. The aim was to determine the rate of electrode migration of the CI electrodes and present clinical and surgical implications.Retrospective patient review.Tertiary referral university hospital.Two hundred seventy-eight patients implanted uni- or bilaterally with lateral wall electrodes designed for hearing preservation (358 implants). The control group was 323 patients implanted uni- or bilaterally with preformed perimodiolar electrodes (468 implants).Determination of CI electrode migration was conducted according to a clinica…
Subthreshold low frequency repetitive transcranial magnetic stimulation selectively decreases facilitation in the motor cortex
2002
Objective: To investigate the modulatory effect of a subthreshold low frequency repetitive transcranial magnetic stimulation (rTMS) train on motor cortex excitability. Methods: The study consisted of two separate experiments. Subjects received a 10 min long subthreshold 1Hz rTMS train. In the first experiment, (single pulse paradigm), cortical excitability was assessed by measuring the amplitude of motor evoked potentials (MEPs) before and after the rTMS train. In the second experiment, a paired pulse paradigm was employed. Results: Corticospinal excitability, as measured by the MEP amplitude, was reduced by the rTMS train (experiment 1), with a significant effect lasting for about 10 min a…