Search results for "Sensory system"
showing 10 items of 1266 documents
Visuospatial attention lateralization in volleyball players and in rowers.
2011
In the present study, differences in visuospatial attention lateralization were evaluated in athletes engaged in open- compared to closed-skill sports and sedentary nonathletes. 23 volleyball players (open skill; Italian national level and regional level), 10 rowers (closed skill, Italian national level), and 23 sedentary participants responded to a computerized line-length judgment task. Five lines, differing in the length of their right and left segments, were randomly presented; the respondent made a forced-choice decision about the respective length of the two segments. Volleyball players responded significantly faster; those at the higher competitive level were also more accurate, mak…
Comparison of Foot and Hand Reaction Times among Men: A Methodologic Study Using Simple and Multiple-Choice Repeated Measurements
1995
The primary study goal was to compare visual simple and choice reaction times of the hand and foot to assess validity of measurements for evaluating subjects' ability to perform rapid, controlled movements. First, we examined the repeatability ( N = 34) for four different data-sampling methods from a series of 12 trials within sessions and between two test sessions. Simple and choice reaction times with the preferred hand and both feet were then compared among 153 healthy male volunteers aged 35 to 67 years. Pearson correlations for hand and ipsilateral and contralateral foot reaction times on simple and choice tasks (.53 to .80, p<.001) showed that psychomotor foot reaction time is a v…
Changes in the visual field following laser in situ keratomileusis for myopia
2007
Purpose: To assess the changes of the visual field (VF) caused by transient intraocular pressure (IOP) peaks during laser in situ keratomileusis (LASIK) surgery for myopia using automated perimetry. Methods: This prospective study involved 94 eyes of 94 patients who underwent a conventional LASIK procedure. A complete eye examination was carried out in which the IOP measurement, and Humphrey 24-2 SITA standard VF were tested prior to LASIK and 6 and 12 months after LASIK. Patients were divided into two subgroups according to their refractive error. VF global indices, Glaucoma Hemifield Test and the number of depressed points deviating at p < 5%, p < 2%, p < 1% and p < 0.5% on the Pattern …
Iris-fixated toric phakic intraocular lens: Three-year follow-up
2006
Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…
Technical note: a comparison of central and peripheral intraocular pressure using rebound tonometry
2007
Purpose: To compare central and peripheral intraocular pressure (IOP) readings obtained with rebound tonometry.Methods: Intraocular pressure was measured on the right eye of 153 patients (65 males, 88 females), aged from 21 to 85 years (mean +/- S.D., 55.5 +/- 15.2 years) with the ICare rebound tonometer at centre, and 2 mm from the limbus (in the nasal and temporal regions along the 0-180O corneal meridian).Results: Intraocular pressure values obtained with the ICare were 14.9 +/- 2.8; 14.1 +/- 2.5 and 14.5 +/- 2.7 mmHg at centre, nasal and temporal corneal locations, respectively. On average, nasal and temporal IOP readings were 0.75 and 0.37 mmHg lower than the central reading (p 0.05, r…
Differential effects on the laser evoked potential of selectively attending to pain localisation versus pain unpleasantness
2004
Abstract Objective : To determine the effects on the laser evoked potential (LEP) of selectively attending to affective (unpleasantness) versus sensory-discriminative (localisation) components of pain. Methods : LEPs, elicited by painful CO 2 laser stimulation of two areas of the right forearm, were recorded from 62 electrodes in 21 healthy volunteers, during three tasks that were matched for generalised attention: Localisation (report stimulus location), Unpleasantness (report stimulus unpleasantness), Control (report pain detection). LEP components are named by polarity, latency, and electrode. Results : N300-T7 peak amplitude was significantly greater during Localisation than Unpleasantn…
Muscle fatigue affects mental simulation of action.
2011
International audience; Several studies suggest that when subjects mentally rehearse or execute a familiar action, they engage similar neural and cognitive operations. Here, we examined whether muscle fatigue could influence mental movements. Participants mentally and actually performed a sequence of vertical arm movements (rotation around the shoulder joint) before and after a fatiguing exercise involving the right arm. We found similar durations for actual and mental movements before fatigue, but significant temporal discrepancies after fatigue. Specifically, mental simulation was accelerated immediately after fatigue, while the opposite was observed for actual execution. Furthermore, act…
Electrophysiological patterns of oropharyngeal swallowing in multiple sclerosis.
2012
Abstract Objective We performed an electrophysiological study of swallowing (EPSS) in multiple sclerosis (MS) to describe oropharyngeal swallowing abnormalities and to analyze their correlations with dysphagia and with overall neurological impairment. Methods Neurological examinations were quantified using the Kurtzke Functional Systems and the Expanded Disability Status Scale (EDSS). Dysphagia was evaluated using the Dysphagia in Multiple Sclerosis (DYMUS) questionnaire, while fiberoptic endoscopic evaluation of swallowing (FEES) was used to establish the degree of aspiration and penetration, graded using the penetration–aspiration scale (PAS). The EPSS measured the duration of suprahyoid/…
Paradoxical heat sensation in patients with multiple sclerosis
1996
Temperature thresholds were determined in 16 patients with probable or definite multiple sclerosis, in six patients with possible but unconfirmed multiple sclerosis and in 34 healthy subjects, using the method of limits and the thermal sensory limen (TSL) of the MarStock technique. A significant proportion of the patients had thresholds outside the 2.5 SD range for normal subjects, both for warmth detection threshold and TSL. In addition, 10 patients with probable or definite multiple sclerosis and one patient with possible multiple sclerosis reported a paradoxical heat sensation, i.e. a sensation of warmth elicited by a cold stimulus. This illusion was almost exclusively observed with the …
Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.
2008
To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…