Search results for "Sensory system"
showing 10 items of 1266 documents
Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.
2005
To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany.In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometri…
Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes.
2004
Abstract Purpose: To evaluate the change in contrast sensitivity after implantation of the Verisyse toric phakic intraocular lens (IOL) (AMO) for the correction of myopia with astigmatism. Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods: Eighteen eyes had implantation of an iris-supported toric phakic IOL to correct myopia with astigmatism. The mean preoperative spherical equivalent was −12.65 diopters ± 3.6 (SD). The contrast sensitivity with best spectacle correction was determined before surgery and 3 months after surgery using the CSV-1000 HGT instrument (Vector Vision Inc.). Results: Three months after IOL implantation, the mean contrast sen…
Perceptual and response bias in visuospatial neglect due to frontal and parietal repetitive transcranial magnetic stimulation in normal subjects.
2002
Recently some authors have challenged the conventional association of directional motor neglect with damage of frontal structures, showing that pure sensory perceptual neglect (classically associated with parietal lesion) can follow damage of right frontal cortex. The aim of the present study was to assess the type of defect in visuo-spatial attention consequent upon a virtual frontal or parietal lesion induced by transcranial magnetic stimulation in normal subjects. To this purpose eleven subjects performed a visuo-spatial task requiring judgement about the length of the two segments of asymmetrically bisected horizontal lines, presented for 50 ms on a computer monitor. After each visual s…
Evaluation of the postural stability of elderly persons using time domain signal analysis
2012
A force platform is widely used in the evaluation of postural stability in man. Although an abundance of parameters are typically retrieved from force platform data, no uniform analysis of the data has been carried out. In general, the signal analysis does not analyze the underlying postural event, i.e., whether the signal consists of several small corrections or large excursions. In the present work, we studied the postural stability of 4589 elderly persons from Iceland on a force platform under visual and non-visual conditions during stance on a solid surface. We analyzed the internal relationship between frequently used time domain variables. In addition, we conducted a factor analysis u…
Cortical Proprioceptive Processing Is Altered by Aging
2018
Proprioceptive perception is impaired with aging, but little is known about aging-related deterioration of proprioception at the cortical level. Corticokinematic coherence (CKC) between limb kinematic and magnetoencephalographic (MEG) signals reflects cortical processing of proprioceptive afference. We, thus, compared CKC strength to ankle movements between younger and older subjects, and examined whether CKC predicts postural stability. Fifteen younger (range 18-31 years) and eight older (66-73 years) sedentary volunteers were seated in MEG, while their right and left ankle joints were moved separately at 2 Hz (for 4 min each) using a novel MEG-compatible ankle-movement actuator. Coherence…
Biogenic Amines Modulate Olfactory Receptor Neurons Firing Activity in Mamestra brassicae
2001
The modulatory effects of the biogenic amines octopamine and serotonin on pheromonal receptor neurons of Mamestra brassicae were investigated. The responses to sex pheromone components of two cells types (A and B) in single male long sensilla trichodea were monitored. Cell types A and B do not respond to the same compound. The response of type A to a pulse of the major sex pheromone component increased 5 min after octopamine injection. Responses of type B to other odorants increased after 30 min. In the absence of any pheromone stimulation the background firing activity of type A increased following octopamine injection. This background activity was used to evaluate the kinetics of octopami…
Somatosensory event-related potentials in the rabbit cerebral and cerebellar cortices: a correspondence with mismatch responses in humans.
2001
Somatosensory event-related potentials (ERPs) were recorded from the cerebellar (CerCx), somatosensory (SomCx) and visual (VCx) cortices in rabbits in two stimulus conditions. In the oddball condition, airpuffs to two different locations in the rabbit's muzzle corresponded to infrequently presented deviant stimuli (oddball-deviants) interspersed with frequently presented standard stimuli. In the deviant-alone condition, deviants (alone-deviants) were presented without standards. ERPs to oddball-deviants differed significantly from those to standards in CerCx and SomCx, but not in VCx. Furthermore, some of these differences were not found between ERPs to alone-deviants and those to standards…
Chapter 1 Pain and hyperalgesia: definitions and theories
2006
Publisher Summary This chapter describes pain as an unpleasant sensory and emotional experience associated with actual or potential tissue damage. It reflects the first-person perspective of pain: “pain is an unpleasant sensory and emotional experience.” “Nociception” is a term that may more adequately reflect these aspects of pain sensation. The chapter reviews that the adequate stimulus to activate the receptive organs of the nociceptive system consists of either actual or potential tissue damage. But not all noxious stimuli are detected by the nociceptive system. Therefore, the adequate stimulus for this system in the strict sense is that subset of noxious stimuli that can be encoded by …
Successful subretinal delivery and monitoring of MicroBeads in mice
2013
BACKGROUND: To monitor viability of implanted genetically engineered and microencapsulated human stem cells (MicroBeads) in the mouse eye, and to study the impact of the beads and/or xenogenic cells on retinal integrity. METHODOLOGY/PRINCIPAL FINDINGS: MicroBeads were implanted into the subretinal space of SV126 wild type mice using an ab externo approach. Viability of microencapsulated cells was monitored by noninvasive retinal imaging (Spectralis™ HRA+OCT). Retinal integrity was also assessed with retinal imaging and upon the end of the study by light and electron microscopy. The implanted GFP-marked cells encapsulated in subretinal MicroBeads remained viable over a period of up to 4 mont…
An odor timer in milk? Synchrony in the odor of milk effluvium and neonatal chemosensation in the mouse.
2012
International audience; Mammalian newborns exhibit avid responsiveness to odor compounds emanating from conspecific milk. Milk is however developmentally heterogeneous in composition as a function of both evolved constraints and offspring demand. The present study aimed to verify whether milk odor attractivity for neonates is equally distributed along lactation in Mus musculus (Balb-c strain). Therefore, we exposed pups varying in age to milk samples collected from females in different lactational stages. The pups were assayed at postnatal days 2 (P2), 6 (P6) and 15 (P15) in a series of paired-choice tests opposing either murine milk and a blank (water), or two samples of milk collected in …