Search results for "Sensory"

showing 10 items of 2427 documents

Psychophysical and electrofunctional contrast sensitivity in cataractous patients treated with bendazac-lysine salt

1990

The clinical progression of the cataract may be influenced by drugs which reduce the denaturation of lens proteins. One of the most promising drugs is the bendazac-lysine salt. The drug was used in a double-blind study of a group of patients with initial cortical cataract in order to evaluate the changes in visual acuity and contrast sensitivity by means of a psychophysical and an electrophysiological method. After 6 months of treatment with bendazac the mean values of visual acuity showed a statistically significant increase in respect to baseline values, as well as an improvement of the threshold of contrast for most spatial frequencies. In the eyes treated with placebo there was no stati…

medicine.medical_specialtyIndazolesVisual acuitygenetic structuresEye diseasemedia_common.quotation_subjectVisual AcuityPlaceboCataractContrast SensitivityLens proteinDouble-Blind MethodOral administrationPhysiology (medical)OphthalmologyBendazacPsychophysicsmedicineHumansContrast (vision)media_commonbusiness.industryAnti-Inflammatory Agents Non-Steroidalmedicine.diseaseeye diseasesSensory SystemsSurgeryElectrophysiologyOphthalmologyElectrophysiologyEvoked Potentials Visualmedicine.symptombusinessPhotic Stimulationmedicine.drugDocumenta Ophthalmologica
researchProduct

Assessment of environmental AMD risk factors in a population of patients suffering from stroke and myocardial infarction

2010

International audience; Purpose: Stroke and myocardial infarction are common diseases occurring in patients suffering from Age Macular Degeneration (AMD). We assessed the rate of AMD and AMD risk factors in patients suffering from recent stroke or myocardial infarction. Methods: Patients suffering from a recent stroke or myocardial infarction (less than 1 month) benefited from a thorough ophthalmic examination with the following measurements and evaluations: visual acuity, intraocular pressure, fundus photography, Raman spectroscopy and macular OCT. In the same time a food questionnaire was dispensed. Finally, blood samples to measure fatty acids and lutein were performed. Results: 74 patie…

medicine.medical_specialtyIntraocular pressureLongitudinal studyVisual acuitygenetic structuresPopulation03 medical and health sciences0302 clinical medicineInternal medicinemedicineMyocardial infarction[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrganseducationStrokeeducation.field_of_study[SDV.MHEP] Life Sciences [q-bio]/Human health and pathologymedicine.diagnostic_testbusiness.industryFundus photographyGeneral MedicineMacular degenerationmedicine.diseaseeye diseases3. Good healthSurgeryOphthalmology[SDV.AEN] Life Sciences [q-bio]/Food and Nutrition[SDV.MHEP.OS] Life Sciences [q-bio]/Human health and pathology/Sensory Organs030221 ophthalmology & optometrysense organsmedicine.symptombusiness[SDV.AEN]Life Sciences [q-bio]/Food and Nutrition030217 neurology & neurosurgery[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
researchProduct

Consequences of dietary omega-3 polyunsaturated fatty acid deficiency on retinal function and intraocular pressure in the rat

2009

Purpose Omega-3 polyunsaturated fatty acids (ω3) are key components in nervous structures but their dietary intakes in the overall population are often below nutritional requirements. A chronic deficiency in ω3 is recognized to be associated with functional impairment of the retina. At the opposite, ω3 supplementation is associated with a reduced risk for AMD. The consequences of ω3 deficiency on other eye structures than the retina, such as ciliary bodies, are scarce. The purpose of our study was to compare the response of the retina and ciliary bodies to dietary ω3 deficiency in terms of fatty acid profile and eye functionality. Methods Two successive generations of Lewis rats (G1 and G2)…

medicine.medical_specialtyIntraocular pressuregenetic structuresPopulationGlaucomaBiology03 medical and health scienceschemistry.chemical_compound0302 clinical medicineCiliary bodyInternal medicinemedicine[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory Organseducationchemistry.chemical_classificationeducation.field_of_studymedicine.diagnostic_testFatty acidRetinalGeneral Medicinemedicine.diseaseeye diseasesOphthalmologyEndocrinologymedicine.anatomical_structureBiochemistrychemistry030221 ophthalmology & optometrysense organs030217 neurology & neurosurgery[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyPolyunsaturated fatty acidElectroretinography
researchProduct

Dietary polyunsaturated fatty acids, intraocular pressure, and glaucoma

2014

Abstract Glaucoma is a progressive optic neuropathy and is the second leading cause of blindness worldwide. Estimations predict that nearly 80 million people will be affected by the disease in 2020. Increased intraocular pressure (IOP) has been recognized as a major risk factor for developing glaucoma. Although IOP-lowering agents have been shown to be effective for decreasing the progression of glaucoma, extensive research has been done to identify modifiable lifestyle factors involved in the pathogenesis of this disease. Among these factors, dietary lipids and particularly dietary polyunsaturated fatty acids (PUFAs) represent a promising approach. The aim of this chapter is to summarize t…

medicine.medical_specialtyIntraocular pressureretinagenetic structuresomega-6[ SDV.AEN ] Life Sciences [q-bio]/Food and NutritionGlaucomaDiseaseBiologyBioinformaticsoptic nerveOptic neuropathyPathogenesis03 medical and health sciences0302 clinical medicinelipidmedicineRisk factor[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory Organs030304 developmental biologychemistry.chemical_classification0303 health sciencesmedicine.diseaseeye diseasesSurgery3. Good health[SDV.AEN] Life Sciences [q-bio]/Food and Nutritionnutritionglaucomachemistry[SDV.MHEP.OS] Life Sciences [q-bio]/Human health and pathology/Sensory Organs[ SDV.MHEP.OS ] Life Sciences [q-bio]/Human health and pathology/Sensory OrgansOptic nerve030221 ophthalmology & optometrysense organsomega-3diet[SDV.AEN]Life Sciences [q-bio]/Food and NutritionPolyunsaturated fatty acidpolyunsaturated fatty acidsintraocular pressure
researchProduct

Latanoprost-induced iris darkening: a morphometric study of human peripheral iridectomies.

2003

Abstract Purpose. This microscopic study was undertaken to compare the melanocytes of peripheral iridectomy specimens from two eyes that had latanoprost-induced iris darkening (LIID) with iridectomies taken from the fellow untreated eyes. Methods. The two patients in this study were the ones who underwent LIID in the latanoprost treated eye from a series of 17 patients requiring bilateral trabeculectomy. The first trabeculectomy procedure provided a control peripheral iridectomy for each patient, whereas the second eye was treated with once daily 50 μg ml−1 latanoprost drops for 6 months. The four peripheral iridectomy specimens from the two LIID patients were subjected to quantitative morp…

medicine.medical_specialtyIridectomygenetic structuresmedicine.medical_treatmentEye diseaseGlaucomaIrisTrabeculectomyMelanocyteBiologyExfoliation SyndromeMelaninCellular and Molecular Neurosciencechemistry.chemical_compoundOphthalmologymedicineTrabeculectomyHumansLatanoprostAntihypertensive AgentsIntraocular PressureMelanosomeMelaninsMelanosomesGranule (cell biology)Anatomymedicine.diseaseeye diseasesSensory SystemsOphthalmologyMicroscopy Electronmedicine.anatomical_structurechemistryIris DiseasesProstaglandins F SyntheticLatanoprostMelanocytessense organsStromal CellsPigmentation DisordersGlaucoma Open-AngleExperimental eye research
researchProduct

Implantation of a custom intraocular lens with a 30-diopter torus for the correction of high astigmatism after penetrating keratoplasty.

2003

Abstract We present a 62-year-old woman who had implantation of an intraocular lens (IOL) with a torus of 30.0 diopters (D) in an eye after penetrating keratoplasty. The patient presented with cataract and a best corrected visual acuity of 20/400. Penetrating keratoplasty was performed in 1975 because of decompensated keratoconus. With a clear but inferiorly decentered corneal graft, visual acuity was limited because of keratoplasty-related high corneal astigmatism of 22.5@156 that could not be successfully treated with spectacles or contact lenses. A custom toric IOL with –30.0 D of cylindrical power was implanted in the capsular bag via a sclerocorneal tunnel incision. Additionally, a sph…

medicine.medical_specialtyKeratoconusRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentEye diseaseVisual AcuityIntraocular lensAstigmatismKeratoconusProsthesis DesignCataractHigh astigmatismLens Implantation IntraocularOphthalmologymedicineHumansDioptreLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismCorneal TopographyMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Oxidative tissue damage after phacoemulsification: influence of ophthalmic viscosurgical devices.

2003

To quantify the oxidative tissue damage after phacoemulsification, correlate the damage to the energy applied, and investigate the influence of ophthalmic viscosurgical devices (OVDs).Department of Ophthalmology, University of Mainz, Mainz, Germany.The study comprised 130 eyes operated on by 1 surgeon using the same phacoemulsification machine. Some eyes received an OVD before phacoemulsification and some did not. Energy values were expressed as phaco time; that is, ultrasound (US) time (seconds) after conversion to 100% phaco power. Patients were grouped as follows: Group 1, phaco time less than 20 seconds and no OVD; Group 2, phaco time 20 to 40 seconds and no OVD; Group 3, phaco time mor…

medicine.medical_specialtyLipid Peroxidesgenetic structuresFree Radicalsmedicine.medical_treatmentSodium hyaluronateAqueous humorLactoseMethylcelluloseThiobarbituric Acid Reactive SubstancesAqueous Humorchemistry.chemical_compoundPostoperative ComplicationsOphthalmologyTissue damageOxazinesMedicineHumansHyaluronic AcidAgedPhacoemulsificationbusiness.industryUltrasoundPhacoemulsificationFree Radical ScavengersSensory SystemsOphthalmologyOxidative StresschemistrySurgeryLipid PeroxidationbusinessJournal of cataract and refractive surgery
researchProduct

The treatment of severe self-injurious behavior through sensory stimulation: A case report

2016

Self-injurious behavior of an institutionalized man with profound intellectual disability was treated with a daily 15-min sensory stimulation program, which consisted of moving the arms and hands of the participant, swinging his body, and massage. The frequency of self-injurious behavior was measured in 10-min sessions. Using a reversal design, it was shown that sensory stimulation decreased the participant’s self-hitting behavior significantly, both in intensity and in frequency. Sensory stimulation is recommended for use in those cases in which functional analysis has shown that self-injury may be reinforced by its sensory consequences.

medicine.medical_specialtyMassageSensory stimulation therapysensory stimulationmedicine.medical_treatmentSensory systemself-injurious behaviorkehitysvammatmedicine.diseaselaitoshoitoPhysical medicine and rehabilitationSelf-injurious behavior; intellectual disabilities; applied behavior analysisIntellectual disabilitymedicineinstitutional careLibrary of Congress Classificationta516intellectual disabilitiesSpecial education; psychologyApplied behavior analysisPsychologyFunctional analysis (psychology)Clinical psychologyitsetuhokäyttäytyminen
researchProduct

Spring constants of capsular tension rings.

2004

Purpose To determine the spring constants of several types of capsular tension rings (CTRs). Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Fourteen models of CTRs provided by 9 companies were tested; all were 11.0 mm in diameter. The CTRs were positioned in a special retainer of a material-testing machine and compressed at a constant speed of 10.0 mm per minute. The distance and force values were recorded, and each CTR model was tested 3 times using a new specimen each time. The resulting measurements were used to calculate a mean spring constant for each CTR model. Results All tested CTRs showed linear proportionality between force and compress…

medicine.medical_specialtyMaterials scienceCompressive StrengthTension (physics)Lens Capsule CrystallineConstant speedBiocompatible MaterialsProstheses and ImplantsCompression (physics)Biocompatible materialSensory SystemsSurgeryOphthalmologySpring (device)Capsular bagZonular dialysismedicineHumansPolymethyl MethacrylateSurgeryComposite materialConstant (mathematics)Journal of cataract and refractive surgery
researchProduct

Healon5 viscoadaptive formulation: Comparison to Healon and Healon GV

2001

Abstract Purpose To compare the rheological characteristics of a viscoadaptive viscoelastic formulation with those of 2 standard ophthalmic viscosurgical devices (OVDs). Setting Department of Ophthalmology, Johannes Gutenberg-University, and Max Planck-Institute for Polymer Research, Mainz, Germany. Methods An independent comparative study of 3 OVDs of sodium hyaluronate (Healon®, Healon GV®, and Healon®5) was performed using the Advanced Rheometric Expansion System to analyze rheologic behavior (eg, dynamic frequency dependence of the complex viscosity) as well as rheological parameters (eg, viscosity at zero shear rate, pseudoplasticity, relaxation time, elastic and viscous modulus). Resu…

medicine.medical_specialtyMaterials scienceRheometryViscosityTurbulenceChemistry PharmaceuticalFrequency dependenceElasticitySensory SystemsViscoelasticityShear rateOphthalmologyViscosityRheologyOphthalmologymedicineSurgeryHyaluronic AcidComposite materialElasticity (economics)Journal of Cataract and Refractive Surgery
researchProduct