Search results for "Seroma"
showing 10 items of 18 documents
New mesh shape and improved implantation procedure to simplify and standardize open ventral hernia repair: a preliminary report.
2010
Introduction Issues in ventral hernia repair are represented by the need for mesh fixation and how to assure a sufficient mesh overlap of the defect. Aiming to resolve these problems, this study describes a modified technique for ventral and incisional hernia repair based upon a newly developed mesh with a special design. This new type of implant allows broader coverage of the abdominal wall and results in tension- and fixation-free repair. Materials and methods A unique geometrically shaped mesh consisting of a large central body and radiating arms was used to repair ventral or incisional hernia. The mesh was intended not to be point-fixated. The friction of the straps passing through the …
Prophylactic Single-use Negative Pressure Dressing in Closed Surgical Wounds After Incisional Hernia Repair: A Randomized, Controlled Trial.
2020
OBJECTIVE A randomized controlled trial (RCT) was undertaken to evaluate whether the prophylactic application of a specific single-use negative pressure (sNPWT) dressing on closed surgical incisions after incisional hernia (IH) repair decreases the risk of surgical site occurrences (SSOs) and the length of stay. BACKGROUND The sNPWT dressings have been associated to several advantages like cost savings and prevention of SSOs like seroma, hematoma, dehiscence, or wound infection (SSI) in closed surgical incisions. But this beneficious effect has not been previously studied in cases of close wounds after abdominal wall hernia repairs. METHODS An RCT was undertaken between May 2017 and January…
Is it really useful the Harmonic scalpel in axillary dissection for locally advanced breast cancer? A case series.
2017
Background. The seroma is one of the most common complications in the axillary lymph nodal dissection (different surgical approaches have been tried to reduce the seroma incidence). In our study we evaluate the outcome of patients using or not the ultrasonic scalpel (Harmonic scalpel) according to a standardized surgical technique. Patients and Methods. From January 2011 to December 2015 120 patients underwent axillary dissection for breast cancer. Patients were divided in two groups: patients belonging to the first group underwent Harmonic scalpel dissection and patients belonging to the second group underwent classical dissection. Each group consisted of 60 patients. Quadrantectomy (QUAD)…
Prospective randomized comparison of conventional instruments and the Harmonic Focus(®) device in breast-conserving therapy for primary breast cancer.
2011
Abstract Background In recent years, surgeons have utilized Harmonic instruments to perform breast cancer resection. Retrospective and prospective studies have demonstrated that the use of this surgical device for mastectomy and axillary dissection can reduce perioperative blood loss, seroma formation, and duration and total amount of drainage. No study has analyzed the feasibility of Harmonic instruments in breast-conserving surgery. We conducted a prospective, randomized clinical trial comparing Harmonic instrument and conventional surgery in the performance of breast-conserving surgery and axillary procedures to determine differences in surgical procedures, postoperative outcome, and com…
Does the use of fibrin glue prevent seroma formation after axillary lymphadenectomy for breast cancer? A prospective randomized trial in 159 patients.
2010
Background Seroma formation frequently occurs in patients who have undergone axillary lymphadenectomy. The aim of the study was to evaluate the effect of fibrin glue in the prevention of seroma formation after axillary lymphadenectomy. Materials and Methods Hundred fifty-nine breast cancer patients about to undergo quadrantectomy or mastectomy plus axillary lymphadenectomy were enrolled in the study and randomized into two groups. Fibrin glue spray applied to the axillary fossa plus placement of closed suction drainage were used in 80 patients (group A); placement of closed suction drainage was only used in 79 patients (group B). Results Group A patients showed a slight advantage with regar…
Does Ligasure(TM) Reduce Fluid Drainage in Axillary Dissection? A Randomised Prospective Clinical Trial
2007
Background: Axillary lymph node dissection (ALND) is an integral part of breast cancer treatment. It is required in about 40–50% of patients. The placement of a drain in the axilla after an operation is current surgical practice. Short surgical stay programmes increase operating efficiency and reduce medical care costs, without compromising quality of care. LigaSureTM is a new haemostatic device that uses bipolar energy to seal vessels. The aim of this study is to determine whether axillary dissection with LigaSureTM reduces the time of wound drainage, the duration of surgical intervention and the volume of drainage after treatment. Patients and methods: This study is a prospective randomiz…
The abdominal wall incisional hernia repair in cirrhotic patients
2018
BACKGROUND: The incidence of abdominal wall hernia in cirrhotic patients with ascites is between 20 and 40%. Controversies regarding the treatment modality and surgical timing of abdominal wall incisional hernia repair in cirrhotic patients remain. The study proposed wants to analyze the abdominal incisional hernia repair in cirrhotic patients with ascites performed in a single center to determine post-operative morbidity, mortality and complication rate. PATIENTS AND METHODS: Cirrhotic patients with abdominal incisional hernia that underwent surgical operation for abdominal wall hernia repair at the "Policlinico Paolo Giaccone" at Palermo University Hospital between January 2015 and Decemb…
Deep seroma after incisional hernia repair. Case reports and review of the literature.
2015
Wound-related complications are common after incisional hernia repair with mesh; seroma formation is the most frequent problem. The formation of a deep seroma has been rarely reported in the literature.In one year, September 2012-2013, 136 patients underwent surgery for incisional hernia repair, both elective and urgent.The following complications were observed: one dislocation of polypropylene prosthesis, a massive relapsed seroma and two deep seromas described in this article. A 63- years-old female underwent open incisional hernia repair with an intraperitoneal PTFE patch. She developed recurrent seroma under the mesh drained percutaneously, and finally the prosthesis was removed. A 72- …
Laparoscopic versus open mesh repair for recurrent inguinal hernia: a meta-analysis of outcomes
2009
Abstract Background The objective of this study was to examine the outcomes of comparisons between laparoscopic and open mesh repairs in the setting of recurrent inguinal hernia. Methods The electronic databases MEDLINE, Embase, Pubmed, and the Cochrane Library were used to search for articles from 1990 to 2008. The present meta-analysis pooled the effects of outcomes of a total of 1,542 patients enrolled into 5 randomized controlled trials and 7 comparative studies, using classic and modern meta-analytic methods. Results Significantly fewer cases of hematoma/seroma formation were observed in the laparoscopic group in comparison with the Lichtenstein group (odds ratio, .38; .15–.96; P = .04…
Multiparametric evaluation of risk factors associated to seroma formation in abdominal wall surgery
2018
INTRODUCTION: Incisional hernia is one of the main topics in the general surgery since there is not a unanimous consensus concerning to the best surgical methodology to adopt. It seems that prosthetic surgery is the best technique, even if responsible for the development of periprosthetic seroma. The aim of this study is to assess whether the preoperative abnormalities of the bio-humoral parameters may be considered as risk factors for seroma. PATIENTS AND METHODS: From July 2016 to July 2017 at the "Policlinico Paolo Giaccone", Palermo, Department of Emergency Surgery, 56 patients included in this study, underwent laparotomic mesh repair. The inclusion criteria were: age > 18 years, inc…