Search results for "Server"

showing 10 items of 586 documents

Speckle myocardial imaging modalities for early detection of myocardial impairment in isolated left ventricular non-compaction

2009

Objective To examine the hypothesis that speckle myocardial imaging (SMI) modalities, including longitudinal, radial and circumferential systolic (s) and diastolic (d) myocardial velocity imaging, displacement (D), strain rate (SR) and strain (S), as well as left ventricular (LV) rotation/torsion are sensitive for detecting early myocardial dysfunction in isolated LV non-compaction (iLVNC). Design and results Twenty patients with iLVNC diagnosed by cardiac magnetic resonance (15) or echocardiography (5) were included. Patients were divided into two groups: ejection fraction (EF)>50% (n=10) and EF≤50% (n=10). Standard measures of systolic and diastolic function including pulsed wave tissue D…

AdultMalemedicine.medical_specialtyDiastoleDoppler imagingechocardiography cardiomyopathy.ArticleVentricular Dysfunction LeftYoung AdultSpeckle patternInternal medicinemedicineHumansUltrasonographyObserver VariationIsolated Noncompaction of the Ventricular MyocardiumEjection fractionmedicine.diagnostic_testbusiness.industryArea under the curveReproducibility of ResultsStroke VolumeMagnetic resonance imagingStroke volumeMiddle AgedSettore MED/11 - Malattie Dell'Apparato CardiovascolareMagnetic Resonance ImagingCirculatory systemCardiologyFemaleCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesHeart
researchProduct

Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography

1996

The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D- echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D- echocardiographic data acquisition was performed by automatic transducer rotation at 2 degree increments over a span of 180 degrees. The transesophageal probe was linked to an ultrasound unit and to a 3D- workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes…

AdultMalemedicine.medical_specialtyDuplex ultrasonographyImage qualitymedicine.medical_treatmentDoppler echocardiographyMitral valve stenosisMitral valveImage Processing Computer-AssistedmedicineHumansMitral Valve StenosisRadiology Nuclear Medicine and imagingCardiac imagingAgedCardiac catheterizationObserver Variationmedicine.diagnostic_testbusiness.industryUltrasoundMiddle Agedmedicine.diseaseEchocardiography Dopplermedicine.anatomical_structureFemaleRadiologyCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealThe International Journal of Cardiac Imaging
researchProduct

Emergency radiology: straightening of the cervical spine in MDCT after trauma--a sign of injury or normal variant?

2016

To evaluate whether straightening of the cervical spine (C-spine) alignment after trauma can be considered a significant multidetector CT (MDCT) finding.160 consecutive patients after C-spine trauma admitted to a Level 1 trauma centre received MDCT according to Canadian Cervical Spine Rule and National Emergency X-Radiography Utilization Study indication rule; subgroups with and without cervical collar immobilization (CCI +/-) were compared with a control group (n = 20) of non-traumatized patients. Two independent readers evaluated retrospectively the alignment, determined the absolute rotational angle of the posterior surface of C2 and C7 (ARA C2-7) and grouped the results for lordosis (-1…

AdultMalemedicine.medical_specialtyEmergency Medical Servicesanimal structuresLordosisAdolescentKyphosisSpinal Curvatures030218 nuclear medicine & medical imaging03 medical and health sciencesYoung Adult0302 clinical medicineTrauma CentersMultidetector Computed TomographyEmergency Radiology special featuremedicineHumansRadiology Nuclear Medicine and imagingKyphosisYoung adultRetrospective StudiesObserver Variationbusiness.industryRetrospective cohort studyGeneral MedicineMiddle Agedmedicine.diseaseCervical spineSpinenervous system diseasesmedicine.anatomical_structureSpinal CurvaturesSpinal InjuriesCervical VertebraeLordosisCervical collarFemaleRadiologybusinesspsychological phenomena and processes030217 neurology & neurosurgeryCervical vertebraeThe British journal of radiology
researchProduct

Left ventricular volume determination using Albunex.

1996

The aim of this study was to assess the ability of intravenous injection of Albunex to improve left ventricular volume determination in patients with various cardiac diseases. It is conceivable that the intravenous injection of microbubbles could improve echocardiographic left ventricular border delineation leading to improved interobserver variability. Echocardiograms were obtained during simultaneous intravenous injection of 0.08 and 0.12 ml/kg Albunex (four-chamber view). Within 6 hours after the recording of the contrast echocardiograms routine left heart angiography was performed. Volumes were measured using the slice method in native and contrast echocardiograms as well as in the angi…

AdultMalemedicine.medical_specialtyHeart DiseasesSystoleCardiac VolumeHeart angiographyContrast MediaEnd systoleVentricular Function LeftDiastoleInternal medicineAlbuminsmedicineConfidence IntervalsHumansRadiology Nuclear Medicine and imagingIn patientEnd diastoleAgedObserver VariationEjection fractionbusiness.industryCineradiographyAngiocardiographyHeartStroke VolumeMiddle AgedConfidence intervalMicrospheresEchocardiographyInjections IntravenousCardiologyMicrobubblesVentricular volumeFemaleCardiology and Cardiovascular MedicinebusinessJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
researchProduct

Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests

2017

The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plo…

AdultMalemedicine.medical_specialtyHeteroscedasticityIntraclass correlationPosturePopulationBiophysicsTraumatologyCorrelation03 medical and health sciencessymbols.namesake0302 clinical medicineActivities of Daily LivingmedicineHumansOrthopedics and Sports MedicineArthroplasty Replacement KneeeducationGaitReliability (statistics)AgedAged 80 and overObserver Variationeducation.field_of_studybusiness.industryRehabilitationReproducibility of ResultsRecovery of Function030229 sport sciencesMiddle AgedConfidence intervalPearson product-moment correlation coefficientsymbolsPhysical therapyFemalebusiness030217 neurology & neurosurgeryGait & Posture
researchProduct

Towards an international language for incontinence-associated dermatitis (IAD): design and evaluation of psychometric properties of the Ghent Global …

2018

Background Incontinence-associated dermatitis (IAD) is a specific type of irritant contact dermatitis with different levels of severity. An internationally accepted instrument to assess the severity of IAD in adults with established diagnostic accuracy, agreement, and reliability is needed to support clinical practice and research.Objectives To design and psychometrically evaluate the Ghent Global IAD Categorisation Tool (GLOBIAD).Methods The design was based on expert consultation using a three-round Delphi procedure with 34 experts from 13 countries. The instrument was tested using IAD photographs reflecting different severity levels in a sample of 823 health professionals in 30 countries…

AdultMalemedicine.medical_specialtyInternationalityPsychometricsPsychometricsFleiss' kappaDermatologySensitivity and SpecificitySeverity of Illness Index030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineTerminology as TopicSeverity of illnessMedicineHumans030212 general & internal medicineLanguageObserver Variationbusiness.industryIntra-rater reliabilityReference StandardsConfidence interval3. Good healthInter-rater reliabilityUrinary IncontinenceCategorization030220 oncology & carcinogenesisPhysical therapyDermatitis IrritantFemalebusinessKappa
researchProduct

Normal reference values of multilayer longitudinal strain according to age decades in a healthy population: A single-centre experience.

2017

Aims Recent advancements in echocardiographic technology allow to analyse myocardial strain in multiple layers. Little is known about the impact of age on layer-specific longitudinal strain in healthy subjects. The aim of this study was to analyse the influence of age on multilayer longitudinal strain and establish normal reference values of layer-specific strain according to age decades in a healthy population referring to our echo laboratory using 2D speckle-tracking echocardiography with layer-specific software. Methods and results Two-hundred sixty-six healthy, consecutive subjects (mean age = 39.2 ± 17.5 years, women/men = 137/129), free of cardiovascular risk factors, were enrolled. S…

AdultMalemedicine.medical_specialtyLongitudinal strain030204 cardiovascular system & hematologyVentricular Function LeftCohort Studies03 medical and health sciences0302 clinical medicineReference ValuesInternal medicineLinear regressionImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineProspective StudiesProspective cohort studyObserver VariationStrain (chemistry)business.industrysubendocardial strainConfoundingsubepicardial strainAge FactorsStroke VolumeGeneral MedicineMiddle AgedHealthy VolunteersageingAgeingEchocardiographyReference valuesCardiologyLinear ModelsFemaleCardiology and Cardiovascular Medicinebusinessglobal longitudinal strainglobal longitudinal strain subepicardial strain subendocardial strain echocardiography ageingCohort studyEuropean heart journal. Cardiovascular Imaging
researchProduct

Associations between intracranial pressure, intraocular pressure and mean arterial pressure in patients with traumatic and non-traumatic brain injuri…

2008

Introduction: Anatomical proximity of the eye and the intracranial space is a fact but the existence of physiological and pathophysiological relationships between them is elusive. The objective of this study was to explore anatomical and pathophysiological interactions between the eye and the intracranial space and to assess clinical utility of intraocular pressure measurement in estimation of intracranial pressure in patients with brain injuries and to discover how haemodynamic instability could influence these interactions. Controversy surrounds the recent literature concerning this problem and the consensus has not been achieved. Materials and methods: We evaluated the correlation betwee…

AdultMalemedicine.medical_specialtyMean arterial pressureIntraocular pressuregenetic structuresAdolescentIntracranial PressurePopulationBlood PressureStatistics NonparametricCentral nervous system diseaseTonometry OcularYoung AdultmedicineHumansProspective StudiesComaeducationIntraocular PressureGeneral Environmental ScienceIntracranial pressureAgedObserver Variationeducation.field_of_studybusiness.industryMiddle Agedmedicine.diseaseeye diseasesBlood pressureAnesthesiaBrain InjuriesOrthopedic surgeryGeneral Earth and Planetary SciencesIntracranial pressure monitoringFemalebusinessInjury
researchProduct

Pancreatic cancer detection with magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography: a prospective contro…

2000

Summary Background Magnetic resonance cholangiopancreatography (MRCP) is a non-invasive and increasingly used procedure in cases involving biliary and pancreatic diseases. However, the accuracy of MRCP in differential diagnosis between pancreatic cancer and chronic pancreatitis has never been documented in a large prospective controlled study. Methods 124 patients were recruited for the study, selected from 141 consecutive patients with an average age of 55 years (range 19–80) who presented to our department between February, 1996, and January, 1998, with a strong clinical suspicion of pancreatic cancer. MRCP images were interpreted by a radiologist and a gastroenterologist who were unaware…

AdultMalemedicine.medical_specialtyPancreatic diseaseBiopsySensitivity and SpecificityGastroenterologyPredictive Value of TestsPancreatic cancerInternal medicineBiopsymedicineHumansProspective StudiesAgedAged 80 and overCholangiopancreatography Endoscopic RetrogradeCommon Bile DuctObserver VariationMagnetic resonance cholangiopancreatographyEndoscopic retrograde cholangiopancreatographymedicine.diagnostic_testbusiness.industryBiopsy NeedleCarcinomaPancreatic DuctsGeneral MedicineMiddle Agedmedicine.diseaseMagnetic Resonance ImagingPancreatic Neoplasmsmedicine.anatomical_structurePancreatitisChronic DiseaseFeasibility StudiesPancreatitisFemaleRadiologyDifferential diagnosisPancreasbusinessFollow-Up StudiesThe Lancet
researchProduct

Inter- and intrarater reliability of two proprioception tests using clinical applicable measurement tools in subjects with and without knee osteoarth…

2017

Abstract Background The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. Objective To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Design Cross-sectional test-retest design. Method Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correl…

AdultMalemedicine.medical_specialtyRange of Motion Articular/physiologyIntraclass correlationPhysical Therapy Sports Therapy and RehabilitationOsteoarthritisMuscle Strength DynamometerKnee Joint03 medical and health sciencesDisability Evaluation0302 clinical medicinePhysical medicine and rehabilitationReference ValuesmedicineHumans030212 general & internal medicineRange of Motion ArticularReliability (statistics)Aged030203 arthritis & rheumatologyObserver VariationOsteoarthritis Knee/diagnosisbusiness.industryRepeated measures designIntra-rater reliabilityMiddle AgedOsteoarthritis Kneemedicine.diseaseProprioceptionKnee painStandard errorCross-Sectional StudiesPhysical therapyFemaleHuman medicinemedicine.symptombusinessProprioception/physiologyMusculoskeletal sciencepractice
researchProduct