Search results for "Shield"

showing 10 items of 177 documents

Preliminary Mechanical Characterization of Thermal Filters for the X-IFU Instrument on Athena

2018

The X-ray Integral Field Unit (X-IFU) is one of the two instruments of the Athena astrophysics space mission approved by ESA in the Cosmic Vision Science Program. The X-IFU consists of a large array of TES microcalorimeters that will operate at ~ 50 mK inside a sophisticated cryostat. A set of thin filters, highly transparent to X-rays, will be mounted on the cryostat thermal shields in order to attenuate the IR radiative load, to attenuate RF electromagnetic interferences, and to protect the detector from contamination. In this paper, we present the current thermal filters design, describe the filter samples developed/procured so far, and present preliminary results from the ongoing charac…

PhysicsCryostatX-IFUCosmic VisionAtomic and Molecular Physics and Opticbusiness.industryDetectorShieldsX-ray microcalorimeterThermal filterCondensed Matter Physics01 natural sciencesAtomic and Molecular Physics and OpticsCharacterization (materials science)OpticsFilter (video)0103 physical sciencesThermalRadiative transferGeneral Materials ScienceAthenaMaterials Science (all)010306 general physicsbusiness010303 astronomy & astrophysics
researchProduct

Magnetic shielding of soft protons in future X-ray telescopes: the case of the ATHENA Wide Field Imager

2018

Both the interplanetary space and the Earth magnetosphere are populated by low energy ($\leq300$ keV) protons that are potentially able to scatter on the reflecting surface of Wolter-I optics of X-ray focusing telescopes and reach the focal plane. This phenomenon, depending on the X-ray instrumentation, can dramatically increase the background level, reducing the sensitivity or, in the most extreme cases, compromising the observation itself. The use of a magnetic diverter, deflecting protons away from the field of view, requires a detailed characterization of their angular and energy distribution when exiting the mirror. We present the first end-to-end Geant4 simulation of proton scattering…

PhysicsField (physics)ProtonAstrophysics::High Energy Astrophysical PhenomenaAstrophysics::Instrumentation and Methods for AstrophysicsMagnetosphereFOS: Physical sciencesAstronomy and AstrophysicsX-ray telescopeField of view01 natural sciencesComputational physicsMagnetic field010309 opticsCardinal pointSpace and Planetary Science0103 physical sciencesElectromagnetic shieldinginstrumentation: miscellaneous – telescopesAstrophysics - Instrumentation and Methods for Astrophysics010303 astronomy & astrophysicsInstrumentation and Methods for Astrophysics (astro-ph.IM)
researchProduct

Collimation of Target Induced Halo Following MAGIX at MESA

2019

The Mainz Energy-recovering Superconducting Accelerator (MESA) will be an electron accelerator allowing operation in energy-recovery linac (ERL) mode. It provides the opportunity to operate scattering experiments at energies of ~100 MeV with thin gas-targets. The MESA Internal Gas Target Experiment (MAGIX) aims to operate windowless jet targets and different gases up to Xenon to search for possible dark photon interactions, to precisely measure the magnetic proton radius and astrophysical S-factors. Investigations on the impact of the target on beam dynamics and beam losses are required for machine safety and to examine limits to ERL operation. The goal of this work is to understand target …

PhysicsHistorybusiness.industryParticle accelerator530Dark photonLinear particle acceleratorCollimated lightComputer Science ApplicationsEducationlaw.inventionAccelerator PhysicsMC6: Beam Instrumentation Controls Feedback and Operational AspectsOpticslawCryomoduleElectromagnetic shieldingPhysics::Accelerator Physicsddc:530HalobusinessBeam (structure)
researchProduct

Mono-energetic electron induced single-event effects at the VESPER facility

2016

We present experimental evidence of electron induced upsets in a reference ESA SEU monitor, the SEU based particle detector, induced by 200 MeV electron beam at the VESPER facility at CERN. Comparison of experimental cross sections and simulated cross sections are shown and the differences are analyzed. Possible secondary contributions to the upset rate by neutrons and cumulative dose effects are discussed, showing that electronuclear reactions are the expected SEU mechanism. Insight is given as to possible overall electron contribution to the upset rates in the Jovian radiation environment inside a typical spacecraft shielding are evaluated.

PhysicsLarge Hadron Collider010308 nuclear & particles physicsElectronRadiation01 natural sciencesUpsetParticle detectorNuclear physics0103 physical sciencesElectromagnetic shieldingCathode rayNeutron010306 general physics2016 16th European Conference on Radiation and Its Effects on Components and Systems (RADECS)
researchProduct

Three-Dimensional Neutronics and Shielding Analyses for the ITER Divertor

1996

3-D neutronics and shielding analyses have been performed for the divertor region of the ITER interim design. The peak neutron wall loading in the divertor region is 0.6 MW/m{sup 2} at the divertor cassette dome. The total nuclear heating in the 60 divertor cassettes is 102.4 MW. The peak helium production in the VV behind the pumping ducts is 0.5 He appm/FPY implying that rewelding might be feasible. The total nuclear heating in the parts of the TF coils in the divertor region is only 2.1 kW. 5 refs., 4 figs., 5 tabs.

PhysicsNeutron transportNuclear heating020209 energyDivertorGeneral EngineeringIter tokamakchemistry.chemical_element02 engineering and technology01 natural sciences010305 fluids & plasmasNuclear physicschemistryHeat flux0103 physical sciencesElectromagnetic shielding0202 electrical engineering electronic engineering information engineeringNeutronHeliumFusion Technology
researchProduct

Magnetized boxes for housing polarized spins in homogeneous fields

2010

Abstract We present novel types of permanently magnetized as well as current powered boxes built from soft-ferromagnetic materials. They provide shielded magnetic fields which are homogeneous within a large fraction of the enclosed volume, thus minimizing size, weight, and costs. For the permanently magnetized solutions, homogenization is achieved either by an optimized distribution of the permanent field sources or by jacketing the field with a soft-ferromagnetic cylindrical shell which is magnetized in parallel to the enclosed field. The latter principle may be applied up to fields of about 0.1 T. With fields of about 1 mT, such boxes are being used for shipping spin-polarized 3 He worldw…

PhysicsNuclear and High Energy PhysicsCondensed matter physicsSpinsBiophysicsMechanicsModels TheoreticalCondensed Matter PhysicsBiochemistryHomogenization (chemistry)Magnetic fieldlaw.inventionMagneticsElectromagnetic FieldsHomogeneouslawShielded cableComputer SimulationSpin LabelsJournal of Magnetic Resonance
researchProduct

The magnetic shielding for the neutron decay spectrometer aSPECT

2014

Abstract Many experiments in nuclear and neutron physics are confronted with the problem that they use a superconducting magnetic spectrometer which potentially affects other experiments by their stray magnetic field. The retardation spectrometer a SPECT consists, inter alia, of a superconducting magnet system that produces a strong longitudinal magnetic field of up to 6.2 T. In order not to disturb other experiments in the vicinity of a SPECT, we had to develop a magnetic field return yoke for the magnet system. While the return yoke must reduce the stray magnetic field, the internal magnetic field and its homogeneity should not be affected. As in many cases, the magnetic shielding for a S…

PhysicsNuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsElectromagnetMagnetic energyDemagnetizing fieldForce between magnetsFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)law.inventionComputational physicsNuclear physicsMagnetizationlawMagnetElectromagnetic shieldingMagnetic pressureNuclear Experiment (nucl-ex)InstrumentationNuclear Experiment
researchProduct

Background radiation effects and hazards in planetary instrumentation

2006

Recent and proposed future planetary missions are becoming increasingly concerned with detailed geochemical assessment, often in a bid to ascertain the presence of water and life supporting geochemical systems. The instruments involved may use some kind of radioactive source, e.g. X-ray fluorescence spectrometry, Mossbauer spectrometry, neutron scattering. Having radioactive sources on a lander/rover poses various potential problems, in regard to both safety to personnel involved in the building of the instrument and to radiation effects on spacecraft structure and on other instruments. Indeed background radiation effects from one instrument may dominate measurements in another resulting in…

PhysicsNuclear and High Energy PhysicsRadiation shieldingSpacecraftbusiness.industryRadioactive sourceFluorescence spectrometryInstrumentation (computer programming)businessInstrumentationPlanetary missionsBackground radiationAstrobiologyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Study of background characteristics of a low-level HPGe spectrometer with passive shielding in various configurations

1997

Abstract A low-background germanium spectrometer has been investigated with different combinations of shielding materials in two locations at ground level. In particular, seven shielding configurations have been tested in a room with thick walls and ceiling. The background components, peaks and continuum in the 50–2600 keV energy region, obtained in the several experimental conditions are reported and discussed.

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industrychemistry.chemical_elementGermaniumSemiconductor detectorGround levelOpticschemistryElectromagnetic shieldingbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Quantitative Determination of Renal 99mTc-MAG3 Clearance. A Comparison of Results Acquired Simultaneously in Whole Body Geometry and with a Gamma Cam…

1997

289 patients were simultaneously investigated with a partially shielded whole body counter (Oberhausen) and in camera technique to correlate the values of the MAG3-clearance. Good correlation was found for the often used times schedules of taking blood samples. Late blood samples increase high clearance values in both methods slighly. The shape of the ROI has no influence using camera technique. We conclude, that camera technique can replace the Oberhausen method with a partially shielded whole body counter.

PhysicsOpticsbusiness.industrylawTime scheduleShielded cableScintillation counterWhole bodybusiness99mTc MAG3Quantitative determinationlaw.inventionGamma camera
researchProduct