Search results for "Shield"
showing 10 items of 177 documents
Quantitative prediction of gas-phase F19 nuclear magnetic shielding constants
2008
Benchmark calculations of (19)F nuclear magnetic shielding constants are presented for a set of 28 molecules. Near-quantitative accuracy (ca. 2 ppm deviation from experiment) is achieved if (1) electron correlation is adequately treated by employing the coupled-cluster singles and doubles (CCSD) model augmented by a perturbative correction for triple excitations [CCSD(T)], (2) large (uncontracted) basis sets are used, (3) gauge-including atomic orbitals are used to ensure gauge-origin independence, (4) calculations are performed at accurate equilibrium geometries [obtained from CCSD(T)/cc-pVTZ calculations correlating all electrons], and (5) vibrational averaging and temperature corrections…
Quantitative prediction of gas-phase N15 and P31 nuclear magnetic shielding constants
2010
High-level ab initio benchmark calculations of the (15)N and (31)P NMR chemical shielding constants for a representative set of molecules are presented. The computations have been carried out at the Hartree-Fock self-consistent field (HF-SCF), density functional theory (DFT) (B-P86 and B3-LYP), second-order Moller-Plesset perturbation theory (MP2), coupled cluster singles and doubles (CCSD), and CCSD augmented by a perturbative treatment of triple excitations [CCSD(T)] level of theory using basis sets of triple zeta quality or better. The influence of the geometry, the treatment of electron correlation, as well as basis set and zero-point vibrational effects on the shielding constants are d…
Overcoming synchronization issues in wireless technology Partial Discharge measurement
2016
In this paper, several aspects of the fundamentals of wireless Partial Discharge (PD) measurements are first discussed. Then, the relevance of the problem of voltage synchronization in PD wireless diagnosis is outlined. When portable instruments are used for PD detection, the main issue is the voltage measurement at the site where the PD detection is carried out. When such analysis is carried out over shielded cables, the AC (50/60 Hz) voltage reference signal is not easily detectable, while one of the basic parameters for PD diagnosis, the displacement of the inception voltage of the PD as compared to the reference voltage, is not available. Even if highperformance sensors are readily avai…
Lightning-current distribution in MV grids interconnected earthing systems
2017
The paper presents first investigations results on the effects of lightning stroke on medium voltage (MV) installations' earthing systems, connected together with the metal shields of the MV distribution grid cables. The study enables to evaluate the distribution of the lightning current among interconnected earth electrodes in order to assess if the interconnection, usually done for reducing earth potential rise during an earth fault, can give place to dangerous situations far from the installation hit by the lightning stroke. Two case studies of direct lightning stroke are presented and discussed: two interconnected MV substations of the MV grid; a high voltage/medium voltage (HV/MV) stat…
On the effects of HV/MV stations on global grounding systems
2016
The METERGLOB project has faced the issue of the identification of Global Grounding Systems. One of the main point of the problem is to define if an interconnection of single grounding systems gives place to a Global Grounding System in any condition and for every kind of ground fault. This paper focuses the attention on what happens in the case of single line to ground fault inside a HV/MV station whose ground electrode is connected to the cable' shields of the MV lines outgoing the station and supplying the secondary substations of a given area.
Attenuation of low frequency magnetic fields produced by HV underground power cables
2015
High-voltage underground cable systems are becoming more common as the demand for electrical power within urban centers increase, also considering the difficulties in building new overhead power lines in the vicinity of city centers because of authorization issues. Therefore, interest towards the evaluation of magnetic fields produced by high-voltage power lines has been triggered during the last decade and concern about effects on human health of exposure to extra low frequency (ELF) magnetic fields due to power lines has been increasing as well. Hence, the evaluation of the magnetic field produced by underground power cables is important in order to develop methods for mitigating their in…
Ground-Fault Current Transfer at the Transition Station of a Combined Overhead-Cable Line. A Parametric Analysis
2007
When a substation is fed by a combined overhead-cable transmission line, a significant part of the ground fault current flows through the grounded cable sheaths and discharges into the earth at the transition station, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, the local ground electrode, small and of high resistance, could be inadequate to maintain the ground potential rise within safety limits in case of a fault to ground at the receiving end substation. Based on a circuit model approach, the paper presents a parametric analysis of the fault current distribution between the faulted substation and the transition station, ta…
A mobile robot for vigilance tasks improved with a new robust and low cost communications system immune to attacks with EMI noise
2006
This work pretends to develop a robot for vigilance tasks that are able to tolerate diverse kinds of attacks and be able to operate in environments with elevated electromagnetic noise, being even immune to sabotage provoked by means of high electromagnetic fields. A new CAN based communications system that interconnects the different devices that compose the mobile robot has been developed to achieve this goal. The system is based on a shielded communications hub, that interconnects diverse nodes by means of CAN. On the other hand, the point to point communication between each node and the hub is carried out by means of economic optical fiber. With this approach all robot devices are connec…
Test bench for coupling and shielding magnetic field
2016
This paper describes a test bench for training purposes, which uses a magnetic field generator to couple this magnetic field to a victim circuit. It can be very useful to test for magnetic susceptibility as well. The magnetic field generator consists of a board, which generates a variable current that flows into a printed circuit board with spiral tracks (noise generator). The victim circuit consists of a coaxial cable concentric with the spiral tracks and its generated magnetic field. The coaxial cable is part of a circuit which conducts a signal produced by a signal generator and a resistive load. In the paper three cases are studied. First, the transmitted signal from the signal generato…
Charge measurement using an array of Faraday’s Cups on a printed circuit board
2014
Abstract An absolute method of measuring charge is to use a Faraday Cup (FC) principle. This study relates to a novel method of measuring charge on a flat substrate, which is coated with charged powder particles. The substrate consists of an array of FC with different dimensions. The sensor is manufactured using flame-retardant printed circuit board (PCB) technology. The objective of this work is to reduce the charge sharing by developing a grounded shield cup around each conductive cup in the array and accordingly increase cup-to-ground capacitance. The results have confirmed that the improved well shielding would provide a more accurate quantitative charge measurement.