Search results for "SiPM"

showing 6 items of 36 documents

Continuous Wave fNIRS with Silicon Photomultiplier

2015

This work is focused on the development of a Continuous Wave (CW) NIRS integrated system with multi-wavelength LED sources between 700 and 950 nm and a Silicon Photomultiplier detector (SiPM) developed by STMicroelectronics. The Signal Noise Rate (SNR), measured placing the LEDs and an SiPM in a direct contact with the surface of a plastic phantom mimicking a real human head, results higher than the calculated minimum, required to detect small variation in the HbO2 and HHb concentration, till a source detector separation (SDS) of 6 cm.

fnirs sipm near infrared spectroscopySettore ING-INF/01 - Elettronica
researchProduct

THE SILICON PHOTOMULTIPLIER:AN IN-DEPTH ANALYSIS IN THE CONTINUOUS WAVE REGIME

2014

The Silicon Photomultiplier (SiPM) is a novel solid state photon counting detector consisting of a parallel array of avalanche photodiodes biased beyond their breakdown voltage. It has known a fast development in the last few years as a possible alternative to vacuum photomultiplier tubes (PMTs) and conventional avalanche photodiodes (APDs). Indeed, current research in photodetectors is directed toward an increasing miniaturization of the pixel size, thus both improving the spatial resolution and reducing the device dimensions. SiPMs show high photon detection efficiency in the visible and near infrared range, low power consumption, high gain, ruggedness, compact size, excellent single-phot…

opalsSPADresponsivitySiPMAPDAvalanche photodiodesingle-photon avalanche diodephotodetectorsnrsilicon photomultiplierSettore ING-INF/01 - Elettronica
researchProduct

Signal to noise ratio measurements of silicon photomultipliers in the continuous wave regime

2014

We report on our signal to noise ratio (SNR) measurements carried out, in the continuous wave regime, on a novel class of silicon photomultipliers (SiPMs) fabricated in planar technology on silicon p-type substrate.

photomultiplier SiPM snr detectorSettore ING-INF/02 - Campi ElettromagneticiSettore ING-INF/01 - Elettronica
researchProduct

A silicon photomultiplier-based analog front-end for DC component rejection and pulse wave recording in photoplethysmographic applications

2022

The growing attention towards healthcare and the constant technological innovations in the field of semiconductor components have allowed a widespread availability of smaller devices, suitable to be worn and able to continuously acquire physiological signals. Wearable devices are, however, more prone to yield signals corrupted by artifacts caused by movement. This issue is particularly relevant in photoplethysmographic (PPG) applications where also, to exploit the whole dynamic range of the acquisition device, the DC component of the signal should be removed and the AC component amplified. In this context, we have designed and realized an analog front-end (AFE) suitable to be integrated wit…

photoplethysmography (PPG)bio-sensing applicationSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaAnalog front-end (AFE)wearable health devices (WHD)silicon photomultiplier (SiPM)Settore ING-INF/01 - Elettronica2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)
researchProduct

P-on-N and N-on-P silicon photomultipliers: responsivity comparison in the continuous wave regime

2013

We report the electrical and optical comparison, in continuous wave regime, of two novel classes of silicon photomultipliers (SiPMs) fabricated on silicon P-type and N-type substrate respectively. Responsivity measurements have been performed with an incident optical power from tenths of picowatts to hundreds of nanowatts and on a broad spectrum, ranging from ultraviolet to near infrared (340-820 nm). For both classes of investigated SiPMs, responsivity shows flat response versus the optical incident power, when a preset overvoltage and wavelength is applied . More in detail, this linear behavior extends up to about 10 nW for lower overvoltages, while a shrink is observed when the reverse b…

sipm photomultiplier responsivity siliconSettore ING-INF/01 - Elettronica
researchProduct

Development of high resolution and efficiency detectors based on Silicon Photomultipliers (SIPMS) and continuous crystals for medical physics applica…

2017

El trabajo presentado en esta tesis introduce y evalúa dos aspectos novedosos en los detectores de rayos gamma para imagen médica: el uso de fotomultiplicadores de silicio (SiPMs, en inglés) acoplados a cristales centelleadores continuos. Tradicionalmente, los tubos fotomultiplicadores (PMTs, en inglés) acoplados a cristales centelleadores han jugado un papel dominante en la detección de rayos gamma. En los últimos años ha aparecido un nuevo tipo de fotodetector de estado sólido, el SiPM, como opción para sustituir a los PMTs en ciertas aplicaciones. Los SiPMs tienen una ganancia y una eficiencia cuántica altas, un voltaje de operación bajo y unas propiedades temporales excelentes. Además, …

sipmscristales continuospetcámara compton:FÍSICA [UNESCO]animales pequeñosUNESCO::FÍSICAterapia hadrónicaasicfotodetectores
researchProduct