Search results for "Significant difference"

showing 10 items of 337 documents

Eco depletion: The impact of hunger on prosociality by means of environmentally friendly attitudes and behavior

2021

Abstract The present research investigated the impact of hunger on prosociality in a consumer choice context by means of environmentally friendly attitudes and behavior. Two eye-tracking studies were conducted with hunger measured (Study 1) and manipulated (Study 2). The data were analyzed through bivariate correlations, Pearson's chi-square tests, and analyses of variance (ANOVAs). Our findings, based on cross-sectional and experimental evidence from field and lab settings, revealed that hungry consumers express more prosocial attitudes than their satiated counterparts in terms of general environmental concerns and importance ratings of buying eco-labeled products. However, we found no sig…

MarketingHungerConsumer choiceEco-labeled foodSignificant differenceContext (language use)Variance (accounting)Prosocial attitudesEnvironmentally friendlyConsumer behaviorProsocial behaviorProsocial behaviorVisual attentionPsychologySocial psychologyVisual attentionConsumer behaviourJournal of Retailing and Consumer Services
researchProduct

The impact of cyberostracism on online complaint handling

2013

Purpose – This research aims to examine how consumers react to being ignored by a company once they have complained about an online service failure. The authors seek to propose that automatic reply e-mails to customer complaints are considered a form of cyberostracism, thus having equally harmful effects on customer perceptions as a mere no reply. Design/methodology/approach – The authors first conducted a qualitative study to ensure that consumers feel ignored when companies fail to respond to their e-mails. This was followed by an experimental study that tested the research propositions. The experimental design was a 3 (ostracism) × 2 (severity of failure) factorial between-subjects desi…

MarketingService (business)Perceptionmedia_common.quotation_subjectSignificant differenceComplaintOstracismAdvertisingBusinessBusiness and International Managementmedia_commonQualitative researchInternational Journal of Retail & Distribution Management
researchProduct

Color memory matching in normal and red-green anomalous trichromat subjects

2001

The methods of simultaneous and successive color matching have been studied for a set of seven color reference samples by 15 protanomalous and 21 deuteranomalous trichromat subjects. From comparison between both populations and a group of 25 trichromat normal ones, investigated previously under similar experimental conditions [J. Perez–Carpinell et al. Color memory matching: time effect and other factors. Color Res Appl 1998;23:234–247], we can deduce the following. (a) For anomalous trichromat populations, as with a normal one, we find significant differences between simultaneous and successive color matching, p < 0.05. (b) If we consider the average of all the colors, we find that, while …

Matching (statistics)Color differencebusiness.industryColor visionGeneral Chemical EngineeringSignificant differenceTrichromacyHuman Factors and ErgonomicsGeneral ChemistryAstrophysicsColor matchingAnomalous trichromacyOpticsbusinessDelay timeMathematicsColor Research &amp; Application
researchProduct

The evaluation of surface sealants effect on the color stability of Nano-hybrid composite after polishing with One-Step system (in-vitro)

2018

Background The clinical use of composite resins has increased substantially over the past few years due to increased esthetic demands by patients, improvements in formulation, and simplification of bonding procedures. An alternative for preventing or reducing composite discoloration is using of composite surface sealant. The purpose of this study was to determine the effect of surface sealant on color-stability of Nano-hybrid composites after polishing with one-step system. Material and Methods 56 disk-shaped specimens (10*2 mm) of a Nano-hybrid composite resin (VOCO,Cuxhaven,Germany) were prepared. The specimens were randomly divided in to 2 groups of 28 specimens each. The surfaces of spe…

Materials science030504 nursingResearchSealantComposite numberSignificant differencePolishingOne-StepEsthetic Dentistry030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Composite surface03 medical and health sciences0302 clinical medicineUNESCO::CIENCIAS MÉDICASNano hybridComposite material0305 other medical scienceGeneral DentistryColor coordinatesJournal of Clinical and Experimental Dentistry
researchProduct

The effect of preheating of composite resin on its color stability after immersion in tea and coffee solutions: An in-vitro study

2019

Background One of the concerns in using composite resins is color change. The aim of this study was to investigate the effect of preheating on color stability of composite resins when immersed in coffee and tea. Material and Methods This experimental study included 60 composite disks. The samples were divided into 2 groups, one group prepared at room temperature and the other prepared at 68 °C. After curing, the samples were placed in 37 °C distilled water for 24 hours. The color of the samples was measured (t0) using spectrophotometer according to CIE-L*a*b* system. The samples of each group were then divided into 3 subgroups and respectively immersed in distillated water, coffee and tea f…

Materials scienceComposite numberSignificant difference030206 dentistry:CIENCIAS MÉDICAS [UNESCO]030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineDistilled waterUNESCO::CIENCIAS MÉDICASIn vitro studyGeneral DentistryCuring (chemistry)Nuclear chemistryJournal of Clinical and Experimental Dentistry
researchProduct

The effect of different insertion techniques on the depth of cure and vickers surface micro-hardness of two bulk-fill resin composite materials

2016

BACKGROUND The aim of this study was to evaluate the Vickers surface micro-hardness and the depth of cure of two bulk-fill resin composites and one incremental-fill resin composite. MATERIAL AND METHODS Two Bulk-fill dental resin composites (X-tra Fil, Voco; Sonic-FillTM 2, Kerr Corporation) and an incremental-fill dental resin composite (Filtek™ Z250 XT, 3M ESPE) were used. Sixty cylindrical specimens of 4 mm thickness were prepared using split Teflon moulds. Specimens were divided into six groups (n=10) according to the type of the material used and according to the insertion technique applied (bulk or incremental). Prepared specimens were stored dry in complete darkness at 37°C for 24 ho…

Materials scienceHardness ratioResin compositeResearchSignificant differenceBulk fillOdontología030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyIndentation hardnessCiencias de la saludOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicineUNESCO::CIENCIAS MÉDICASDental resin compositeComposite material0210 nano-technologyGeneral Dentistry
researchProduct

Bond strength of dental nanocomposites repaired with a bulkfill composite

2017

Background The aim of this study was to analyze the bond strength of aged resin based nanocomposites repaired with the same and bulk fill composites. Material and Methods Seventy-two disc shaped resin composites consisted of three different nanocomposite resins (Filtek Ultimate/FU, Herculite XRV Ultra/HXRV, and Reflectys/R) were produced. After storing the samples for 8 weeks in distilled water, each material was combined with the same material or the bulk-fill composite resin system (Filtek Ultimate+Filtek Ultimate/Group-1; Filtek Ultimate+Tetric BF/Group-2; Herculite XRV+Herculite XRV/Group-3; Herculite XRV+Tetric BF/ Group-4; Reflectys+Reflectys/Group 5; Reflectys+Tetric BF/Group-6), for…

Materials scienceNanocompositeBond strengthResearchResin compositeComposite numberSignificant differenceBulk fill030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicineHerculite XRVUNESCO::CIENCIAS MÉDICASAdhesiveComposite material0210 nano-technologyGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct

Evaluation of microhardness, sorption, solubility, and color stability of bulk fill resins : a comparative study

2020

Background Due to the increasing popularity of bulk fill resins, there is a concern that their components can be leached; this is because these are inserted in a single 4-5 mm increment. This in vitro study evaluated the microhardness, sorption, solubility, and color stability of three restorative bulk fill resins, namely: Filtek Bulk Fill (FBF), Tetric N-Ceram Bulk Fill (TNC), and Opus Bulk Fill (OBF). Material and Methods Cylindrical samples were fabricated to be 15 mm in diameter and 1 mm thick (n = 10). For the microhardness test, three random indentations were formulated on the samples using a micro-durometer with a load of 300 gf for 15 s. Sorption and solubility were then evaluated (…

Materials scienceResearchComposite numberSignificant differenceAnalytical chemistrySorptionBulk fill:CIENCIAS MÉDICAS [UNESCO]Indentation hardnessDistilled waterUNESCO::CIENCIAS MÉDICASImmersion (virtual reality)SolubilityOral SurgeryGeneral Dentistry
researchProduct

Fracture resistance of endodontically treated teeth with different direct corono-radicular restoration methods.

2016

BACKGROUND Endodontically treated teeth are widely considered to be more susceptible to fracture than vital teeth. Obturation procedures and post placement have been a main cause of vertical root fracture. MATERIAL AND METHODS Forty-eight human premolars with standardized weakened roots were endodontically treated and allocated to four experimental groups (n=12). After root canal treatment, in group 1, fiber posts #1 were cemented in root canals using Estelite Core Quick, and the crowns were restored with resin composite. For group 2 and 3, the roots and crowns were restored using a light-cured and self-cured adhesive and resin composites respectively. In group 4, it was used the Panavia F …

Materials scienceRoot canalResin compositemedicine.medical_treatment0206 medical engineeringDentistry02 engineering and technologyCrown (dentistry)Operative Dentistry and Endodontics03 medical and health sciences0302 clinical medicineVertical root fracturestomatognathic systemmedicineGeneral DentistryResin cementbusiness.industryResearchSignificant differencetechnology industry and agriculture030206 dentistry:CIENCIAS MÉDICAS [UNESCO]medicine.disease020601 biomedical engineeringstomatognathic diseasesmedicine.anatomical_structureUNESCO::CIENCIAS MÉDICASFracture (geology)AdhesivebusinessJournal of clinical and experimental dentistry
researchProduct

Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vi…

2017

Background: Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. Aim: The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. Design: Experimental single blinded randomized type of in vitro study with sample of 30 single rooted teeth. Endodontic access cavities were prepared and the root canals were filled with the suspension of E. faecalis. Myers and Montogomery Model was used to collect apically extruded debris and irrigant. Canals …

Materials sciencebusiness.industry0206 medical engineeringSignificant differenceDentistryOdontología030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]Ciencias de la salud020601 biomedical engineering03 medical and health sciences0302 clinical medicineUNESCO::CIENCIAS MÉDICASIn vitro studyApical extrusionStatistical analysisRotary instrumentationbusinessGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct