Search results for "Simulation."
showing 10 items of 4779 documents
A criterion for the assessment of the reliability of ASHRAE conduction transfer function coefficients
2010
This paper presents a new mathematical approach, which, when applied to conduction transfer functions (CTFs) of a multi-layered wall, is able to predict the reliability of building simulations. This new procedure can be used to identify the best set of CTF coefficients, which are a critical point at the core of the ASHRAE calculation methodology founded on the transfer function method. To evaluate the performance of different CTF coefficient sets, the authors performed a large number of thermal simulations on the multi-layered walls included in the ASHRAE Handbook, volume fundamentals, and on other walls typical of Mediterranean building heritage. Those data were employed to test an algorit…
Is the transfer function method reliable in a European building context? A theoretical analysis and a case study in the South of Italy
2005
Abstract The available tools for dynamic simulation of the buildings thermal behaviour are manifold, and the most modern ones, known as TRNSYS, are founded upon the use of the Z-transform (ZT) set also called transfer function method (TFM). The transfer function method (TFM), recommended by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), is one of the most modern tools available to solve heat transfer problems in building envelopes and environments. TFM utilises Z-transforms to solve the equation system that describes the heat transfer in a multi-layered wall. Due to an analogy with an electric circuit, it is possible to write the equation system in a mat…
Simulation of stability and dynamics of multistage flash desalination
2011
gPROMS software was used to study the dynamics of a multistage flash desalination brine circulation system (MSF-BR) as a function of major operating parameters. Most of the previous studies focused on MSF-BR dynamic model development however; it gave very little information on dynamic response of the system to the most significant process independent parameters. The present model was first validated against available industrial data of different plants. System dynamics were obtained upon increasing/decreasing several of the operating parameters over a range of ± 15%. Results show that increase/decrease of the cooling seawater flow rate have limited effect on the system dynamics. Increasing/…
Coupling CFD with a one-dimensional model to predict the performance of reverse electrodialysis stacks
2017
Abstract Different computer-based simulation models, able to predict the performance of Reverse ElectroDialysis (RED) systems, are currently used to investigate the potentials of alternative designs, to orient experimental activities and to design/optimize prototypes. The simulation approach described here combines a one-dimensional modelling of a RED stack with a fully three-dimensional finite volume modelling of the electrolyte channels, either planar or equipped with different spacers or profiled membranes. An advanced three-dimensional code was used to provide correlations for the friction coefficient (based on 3-D solutions of the continuity and Navier-Stokes equations) and the Sherwoo…
Steady State and Dynamic Models of Multistage Flash Desalination: A Review
2010
This article focuses on a review of literature studies on steady state and dynamic modeling of the multistage flash desalination process (MSF). The review shows that both steady state and dynamic models are based on lumped parameter approach. Differences in literature models are found in the assumptions used to model the flashing stage in addition to the correlations used to determine the heat transfer coefficients, thermodynamic losses, thermodynamic and transport properties. Interestingly, literature indicates a rapid progress made in software used for coding and solution of the model equations. The review shows a limited number of literature models for the internals of the flashing stage…
Nonlinear control of an activated sludge aeration process: use of fuzzy techniques for tuning PID controllers
1999
In this paper, several tuning algorithms, specifically ITAE, IMC and Cohen and Coon, were applied in order to tune an activated sludge aeration PID controller. Performance results of these controllers were compared by simulation with those obtained by using a nonlinear fuzzy PID controller. In order to design this controller, a trial and error procedure was used to determine, as a function of error at current time and at a previous time, sets of parameters (including controller gain, integral time and derivative time) which achieve satisfactory response of a PID controller actuating over the aeration process. Once these sets of data were obtained, neural networks were used to obtain fuzzy m…
Automatic Computation of Local Comfort Conditions in Buildings
2000
Publisher Summary A method for the automatic calculation of local comfort conditions in moderate indoor environment is been described in this chapter. It provides, among its output features, graphical maps of the PMV patterns. The program has been implemented on the commonly used operating system, and is characterized by a friendly usability, even by noncomputer expert users. The output of the code can be obtained not only in a graphical way but also in numerical formats. By using the program in conjunction with computer codes that provide the energy demand for climatization of buildings, it would be possible to evaluate the energy savings achieved in correspondence with the various adopted…
Modeling the Sequential Switching Shunt Series Regulator
2005
This letter characterizes, in terms of the bandwidth and limit cycle frequency of its constituent subsystems, the sequential switching shunt series regulator -S/sup 4/R, a high-efficiency, low-mass and volume power cell devised to power the next generation of regulated power buses in telecommunication spacecrafts. Transconductance power source modeling is used to obtain linear and nonlinear models. These are used to establish a design control strategy which involves the dynamic response in large load requirements or at the end of the satellite life. Simulations and experimental results are also given to demonstrate the validity of the model.
A robust calibration methodology for an On-Board Diagnostic car system
2006
New car models are now by law equipped with on-board diagnostic (OBD) systems aimed at monitoring the state of health of strategic components that ensure low levels of polluting exhaust emissions. During development phases, for each new car model, the OBD system must be finely calibrated. This article presents a robust calibration methodology taking into account sources of variability mainly due to production process, operating, and environmental conditions. The methodology enables us to evaluate the false alarm and failure to detect risks intrinsically related to the adopted calibration. An application concerning an upstream oxygen sensor monitored by the OBD is presented.
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…