Search results for "Solid Phase Extraction"

showing 10 items of 297 documents

Sample Preparation to Determine Pharmaceutical and Personal Care Products in an All-Water Matrix: Solid Phase Extraction

2020

© 2020 by the authors.

ConcentrationWater samplesPharmaceuticals and personal care productsPharmaceutical ScienceSewageReviewCosmeticsWastewater010501 environmental sciences01 natural sciencesEnvironmental impact of pharmaceuticals and personal care productsAnalytical ChemistryAigua AnàlisiTandem Mass SpectrometryDrug DiscoverySample preparationOnlineSolid phase extractionProcess engineeringGroundwaterChromatography High Pressure LiquidSewageDispersive liquid-liquid microextractionSolid Phase ExtractionDisksPharmaceutical PreparationsWastewaterChemistry (miscellaneous)Molecular MedicineEnvironmental MonitoringFarmacologiaLiquid Phase MicroextractionCartridgesSensitivity and SpecificityWater PurificationIsolationlcsh:QD241-441lcsh:Organic chemistryPhysical and Theoretical Chemistry0105 earth and related environmental sciencesSolid-phase extractionbusiness.industry010401 analytical chemistryOrganic ChemistryAnalytical techniqueExtraction (chemistry)Water0104 chemical sciencesEnvironmental sciencebusinessSurface waterWater Pollutants Chemical
researchProduct

Polish Yellow Sweet Clover (Melilotus officinalis L.) Honey, Chromatographic Fingerprints, and Chemical Markers

2017

A case study of Polish Melilotus officinalis honey was presented for the first time. Gas chromatography–mass spectrometry (GC-MS) (after steam distillation, Soxhlet extraction, ultrasonic solvent extraction, and solid phase extraction (SPE)) and targeted high performance liquid chromatography with a photodiode array detector (HPLC-PAD) were applied to determine the characteristic components of honey. While ubiquitous in most honeys, carbohydrates, terpene derivatives, and phenylacetic acid dominated in the Soxhlet extracts (25.54%) and in the application of SPE (13.04%). In addition, lumichrome (1.85%) was found, and may be considered as a marker of this honey. Due to the presence of these …

DPPHFlavonoidPharmaceutical Science01 natural sciencesHigh-performance liquid chromatographyvolatileAntioxidantsCatechinGas Chromatography-Mass SpectrometryArticleAnalytical Chemistrylaw.inventionlcsh:QD241-441Steam distillationchemistry.chemical_compound0404 agricultural biotechnologyPhenolslcsh:Organic chemistryMelilotus officinalislawGallic AcidDrug DiscoveryMedicagoHumansGallic acidSolid phase extractionPhysical and Theoretical ChemistryChromatography High Pressure LiquidFlavonoidschemistry.chemical_classificationChromatographybiology010401 analytical chemistryOrganic ChemistryExtraction (chemistry)honey markersHoney04 agricultural and veterinary sciencesbiology.organism_classificationMelilotus officinalis040401 food science0104 chemical sciencesyellow sweet cloverchemistryChemistry (miscellaneous)yellow sweet clover; <i>Melilotus officinalis</i>; phenolic; volatile; honey markersMolecular MedicinephenolicMolecules; Volume 22; Issue 1; Pages: 138
researchProduct

Liquid Chromatographic Analysis of Amphetamine and Related Compounds in Urine Using Solid-Phase Extraction and 3,5-Dinitrobenzoyl Chloride for Deriva…

1997

A chromatographic method for the analysis of amphetamine and related compounds in urine using 3,5-dinitrobenzoyl chloride (3,5-DNB) as a labeling reagent is presented. This assay is based on the employment of solid-phase extraction (SPE) cartridges for sample cleanup and derivatization. Experimental conditions are optimized for the simultaneous derivatization of ephedrine, norephedrine, pseudoephedrine, beta-phenylethylamine, amphetamine, methamphetamine, and 3-phenylpropylamine. The derivatives formed are separated in a LiChrospher 1000 RP18 (125 x 4-mm i.d., 5-microns film thickness) analytical column using a water-acetonitrile gradient elution and detected at 254 nm. Derivatization in C1…

Detection limitAnalyteChromatographyAmphetaminesGeneral MedicinePseudoephedrineHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundchemistryNitrobenzoatesReagentmedicineIndicators and ReagentsSolid phase extractionEphedrineDerivatizationChromatography High Pressure Liquidmedicine.drugJournal of Chromatographic Science
researchProduct

Sequential-injection determination of traces of disodium phenyl dibenzimidazole tetrasulphonate in urine from users of sunscreens by on-line solid-ph…

2005

Abstract A sensitive and selective method to determine disodium phenyl dibenzimidazole tetrasulphonate (PDT) in the urine of sunscreen users, which is suitable for studies on body accumulation/excretion is proposed. On-line solid-phase extraction allows the analyte to be retained and subsequentely eluted, using a strong anion exchange (SAX) microcolumn. Standard addition calibration was carried out with only one standard. The wavelengths of excitation and emission were 330 and 454 nm, respectively. The method allows PDT to be determined in both, spiked and unspiked human urine samples, without any pre-treatment. Results obtained for spiked urine samples (40–200 ng ml −1 ) showed the accurac…

Detection limitAnalyteChromatographyChemistryElutionAdministration TopicalSkin AbsorptionClinical BiochemistryFluorescence spectrometryReproducibility of ResultsPharmaceutical ScienceUrineHydrogen-Ion ConcentrationAnalytical ChemistryExcretionSpectrometry FluorescenceStandard additionFlow Injection AnalysisDrug DiscoveryHumansBenzimidazolesSolid phase extractionSunscreening AgentsSpectroscopyJournal of Pharmaceutical and Biomedical Analysis
researchProduct

Determination of 3-(4′-methylbenzylidene)camphor and its metabolite 3-(4′-carboxybenzylidene)camphor in human semen by solid-phase extraction and liq…

2015

An analytical method for the determination of the controversial UV filter 3-(4′-methylbenzylidene)camphor (MBC) and its metabolite 3-(4′-carboxybenzylidene)camphor (CBC) in human semen is presented. The method is based on the simultaneous hydrolysis of phase II conjugates and protein precipitation, followed by solid-phase extraction (SPE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) detection. The proposed method was validated by analyzing spiked analyte-free human semen samples. Matrix-matched calibration using an analyte-free semen pool was employed. Satisfactory recoveries (92–114%) were obtained using this calibration methodology, thus showing the accuracy of the propos…

Detection limitAnalyteChromatographyChemistryGeneral Chemical EngineeringMetaboliteGeneral EngineeringMass spectrometryAnalytical Chemistrychemistry.chemical_compoundCamphorLiquid chromatography–mass spectrometryProtein precipitationSolid phase extractionAnalytical Methods
researchProduct

Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

2013

Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including prac…

Detection limitAnalyteChromatographyChemistryOrganic ChemistryExtraction (chemistry)Analytical chemistryGeneral MedicineSolid-phase microextractionBiochemistryAnalytical ChemistryMeasuring instrumentSample preparationSample collectionSolid phase extractionSolid Phase MicroextractionJournal of chromatography. A
researchProduct

New micromethod combining miniaturized matrix solid-phase dispersion and in-tube in-valve solid-phase microextraction for estimating polycyclic aroma…

2008

Abstract Miniaturized matrix solid-phase dispersion (MSPD) was developed for the extraction of common polycyclic aromatic hydrocarbons (PAHs) from bivalve samples (100 mg, dry weight). Additional clean-up and analyte enrichment was accomplished by in-tube solid-phase microextraction (SPME). For this purpose the extracts collected after MSPD were diluted with water and injected into a capillary column coated with the extractive phase. This capillary column was connected to the analytical column by means of a switching valve. Separation and quantification of the PAHs were carried out using a monolithic LC column and fluorescence detection. Since the in-tube SPME device allowed the processing …

Detection limitAnalyteChromatographyChemistryOrganic ChemistryExtraction (chemistry)Analytical chemistryReproducibility of ResultsGeneral MedicineReference StandardsSolid-phase microextractionBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryBivalviaMatrix (chemical analysis)AnimalsSample preparationSolid phase extractionPolycyclic Aromatic HydrocarbonsSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct

Sensitive determination of ethacrynic acid in urine samples by reversed-phase liquid chromatography with ultraviolet detection using solid-phase extr…

1992

Abstract A rapid method is described for the identification and determination of ethacrynic acid in human urine samples by liquid chromatography with UV detection, the retention time of the analyte being 4.9 min. The samples were previously conditioned using C 18 solid-phase extraction columns and chromatographed on an HP-LiChrospher RP C 18 column (5 μm; 125 mm × 4 mm i.d.) with gradient elution with acetonitrile-acetate buffer (pH 4). The detector was set at 275 nm and furosemide was used as an internal standard. The procedure was applied to the determination of ethacrynic acid at concentrations of 0.01-10 μg ml -1 and the limit of detection was 6 ng ml -1 .

Detection limitAnalyteChromatographyChemistrymedicine.medical_treatmentExtraction (chemistry)UrineReversed-phase chromatographyBiochemistryAnalytical ChemistrymedicineEnvironmental ChemistrySample preparationSolid phase extractionDiureticSpectroscopyAnalytica Chimica Acta
researchProduct

A solid-phase extraction liquid chromatography-tandem mass spectrometry method for the percutaneous absorption assessment of 3-(4′-methylbenzylidene)…

2013

The UV filter 3-(4′-methylbenzylidene)camphor (MBC) is a common ingredient in sunscreen cosmetic products. However, different in vitro and in vivo studies suggest that MBC can cause endocrine disrupting effects. This report focuses on the development of an analytical method based on solid-phase extraction (SPE) prior to liquid chromatography tandem mass spectrometry (LC-MS/MS) for the determination of MBC and its main phase I metabolite, named 3-(4′-carboxybenzylidene)camphor (CBC), in urine from users of sunscreen cosmetic products containing MBC. The formation of phase II metabolites (i.e., glucuronide and sulphate conjugates) was also considered by carrying out an enzymatic hydrolysis of…

Detection limitAnalyteChromatographyGeneral Chemical EngineeringMetaboliteGeneral EngineeringAnalytical ChemistryCamphorchemistry.chemical_compoundchemistryLiquid chromatography–mass spectrometryStandard additionSolid phase extractionGlucuronideAnal. Methods
researchProduct

Development of a fully automated sequential injection solid-phase extraction procedure coupled to liquid chromatography to determine free 2-hydroxy-4…

2010

Abstract 2-Hydroxy-4-methoxybenzophenone and 2-hydroxy-4-methoxybenzophenone-5-sulphonic acid, commonly known as benzophenone-3 (BZ3) and benzophenone-4 (BZ4), respectively, are substances widely used as UV filters in cosmetic products in order to absorb UV radiation and protect human skin from direct exposure to the deleterious wavelengths of sunlight. As with other UV filters, there is evidence of their percutaneous absorption. This work describes an analytical method developed to determine trace levels of free BZ3 and BZ4 in human urine. The methodology is based on a solid-phase extraction (SPE) procedure for clean-up and pre-concentration, followed by the monitoring of the UV filters by…

Detection limitAnalyteChromatographymedicine.diagnostic_testChemistryElutionSolid Phase ExtractionExtraction (chemistry)TemperatureHydrogen-Ion ConcentrationBiochemistryAnalytical ChemistryBenzophenonesSpectrophotometryStandard additionmedicineHumansEnvironmental ChemistrySpectrophotometry UltravioletSolid phase extractionSelectivitySunscreening AgentsChromatography High Pressure LiquidSpectroscopyAnalytica Chimica Acta
researchProduct