Search results for "Solid phase extraction"
showing 10 items of 297 documents
Analysis of perfluorinated compounds in sewage sludge by pressurized solvent extraction followed by liquid chromatography–mass spectrometry
2011
Perfluorinated compounds (PFCs) are widely used in everyday life and one of the main recipients of these compounds is waste water treatment plants (WWTPs). Due to the structure and physicochemical properties of PFCs, these compounds could be redistributed from influent water to sludge. This work reports a new validated protocol for the analysis of 13 perfluorinated acids, 4 perfluorosulfonates and the perfluorooctanesulfonamide. The present work has been focused to develop a sensitive and robust method for the analysis of 18 PFCs in sewage sludge, based on pressurized solvent extraction (PSE) followed by solid phase extraction (SPE) clean-up, analytes separation by liquid chromatography and…
Mycotoxin Incidence in Some Fish Products: QuEChERS Methodology and Liquid Chromatography Linear Ion Trap Tandem Mass Spectrometry Approach
2019
The inclusion of vegetal raw materials in feed for fish farming has increased the risk of mycotoxin occurrence in feed, as well as in edible tissues from fish fed with contaminated feed, due to the carry-over to muscle portions. Therefore, the objective of this study was to evaluate the occurrence of 15 mycotoxins in processed fish products, which are commonly consumed, such as smoked salmon and trout, different types of sushi, and gula substitutes. A QuEChERS method was employed to perform the mycotoxin extraction from fish samples. For mycotoxin identification and quantitation, the selected technique was the liquid chromatography-tandem mass spectrometry linear ion trap (LC-MS/MS-LIT). Sm…
Sensitive screening of synthetic cannabinoids using liquid chromatography quadrupole time-of-flight mass spectrometry after solid phase extraction.
2021
Analysis of synthetic cannabinoids still poses a challenge for many institutions due to the number of available substances and the constantly changing drug market. Both new and well-known substances keep appearing and disappearing on the market, making it hard to adapt analytical methods in a timely manner. In this study, we developed a qualitative screening approach for synthetic cannabinoids and their metabolites by means of liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF-MS). Samples were measured in data-dependent auto-MS/MS mode and identified by fragment spectra, retention time and accurate mass. Two established solid phase extractions were compared using fo…
Determination of fatty alcohol ethoxylates by derivatisation with maleic anhydride followed by liquid chromatography with UV-vis detection.
2007
The esterification of fatty alcohol ethoxylates (FAEs) by melting with maleic anhydride has been studied in the presence of urea. The reaction rate and yield of non-ethoxylated and ethoxylated alcohols increase largely when grinded urea is suspended in the reaction medium, a 100% yield being achieved at 80 degrees C in 15 min. The procedure is tolerant to the presence of large amounts of water. The UV-vis response factors of the derivatives of individual FAE oligomers vary little with the number of carbon atoms in the alkyl chain, n, and the number of ethylene oxide units, m. Derivatised samples of industrial FAE mixtures, cleaning products and river and sea waters were chromatographed on a…
A new proposal for the determination of polychlorinated biphenyls in environmental water by using host-guest adsorption
2020
Abstract Polychlorinated biphenyls (PCBs) are ubiquitous environmental pollutants whose wide industrial use has been banned over the years in most countries due to their persistence and bioaccumulation. In fact, the International Agency for Research on Cancer defined them in 2016 as carcinogenic to humans based on sufficient evidence of an increased risk of cancer, being children and pregnant or lactating women the most vulnerable population subgroups. In this work, a new alternative for the determination of polychlorinated biphenyls (PCB28, PCB52, PCB101, PCB138, PCB153, and PCB180) in water samples has been developed by using a cyclodextrin-containing silica microparticulated material as …
Application potential of dummy molecularly imprinted polymers as solid-phase extraction sorbents for determination of low-mass polybrominated dipheny…
2019
Abstract Despite the introduction of restrictive regulations in the USA and the European Union, polybrominated diphenyl ethers (PBDEs) are still found in various types of environmental and biological samples at significant concentration levels. The presence of these persistent organic pollutants in the environment raises important issues because of their negative impact on immunological and neurological systems, and on the hormonal balances in living organisms. From the analytical point of view, the final determination of PBDEs would entail substantial challenges, because it would necessitate conducting the pre-concentration of analytes, or sample clean up. The aim of the present study is t…
Assessing drugs of abuse distribution in Turia River based on geographic information system and liquid chromatography mass spectrometry
2017
Drugs of abuse are continuously discharged into wastewaters as part of their elimination process. Pollution at very low concentrations appears to be broad in environmental compartments near populated areas. A total of 42 drugs of abuse and metabolites were analysed in surface water samples collected in 2012 and 2013 by solid phase extraction and liquid chromatography coupled to mass spectrometry. Analytical results of target compounds were georeferenced and integrated into a geographical information systems (GIS). Ecotoxicological risk of drugs of abuse detected in the Turia River was evaluated in this study by calculating risk quotient (RQ). In 2012, 6 compounds were detected in a total of…
Perfluoroalkyl substance contamination of the Llobregat River ecosystem (Mediterranean area, NE Spain).
2014
The occurrence and sources of 21 perfluoroalkyl substances (PFASs: C4-C14, C16, C18 carboxylate, C4, C6-C8 and C10 sulfonates and C8 sulfonamide) were determined in water, sediment, and biota of the Llobregat River basin (NE Spain). Analytes were extracted by solid phase extraction (SPE) and determined by liquid chromatography triple quadrupole mass spectrometer (LC-QqQ-MS). All samples were contaminated with at least one PFAS, being the most frequently found perfluorobutanoate (PFBA), perfluorooctanoate (PFOA) and perfluorooctane sulfonate (L-PFOS). In general, mean PFAS concentrations measured in sediments (0.01-3.67 ng g(-1)) and biota (0.79-431 μg kg(-1)) samples were higher than those …
Development of pipette tip-based poly(methacrylic acid-co-ethylene glycol dimethacrylate) monolith for the extraction of drugs of abuse from oral flu…
2019
Abstract In this work, a monolithic polymer based on poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MAA-co-EDMA) was prepared inside 200 μL pipette tips for the extraction of drug of abuse from oral fluid samples. After an appropriate surface tip modification, several polymerization mixtures with different monomer/cross-linker ratios, and percentage of porogen were studied. The most appropriate monolith to easily flow organic solvents and oral fluid samples was prepared with a MAA/EDMA ratio of 8:92 wt/wt and dodecanol containing 10 wt% toluene, as porogenic solvent. Parameters affecting the extraction procedure were evaluated and the monolith was characterized in terms of bindin…
Surface molecularly imprinted silica for selective solid-phase extraction of biochanin A, daidzein and genistein from urine samples
2015
Selective molecularly imprinted silica polymer (SiO2MIP) for extraction of biochanin A, daidzein and genistein was synthesized using the surface molecular imprinting technique with the silica gel as a support. Biochanin A (BCA) was used as a template, 3-aminopropyltriethoxysilane (APTES) as a functional monomer, and tetraethoxysilicane (TEOS) as a cross-linker. Non-imprinted polymer with the sol–gel process (SiO2NIP) was also prepared for comparison. The synthesized polymers were characterized by Fourier transform infrared spectrometry (FTIR), scanning electron microscopy (SEM) and a standard Brunauer-Emett-Teller (BET) and Barret–Joyner–Halenda (BJH) analysis. The obtained results indicate…