Search results for "Solid"
showing 10 items of 3575 documents
In-tube solid phase microextraction coupled to miniaturized liquid chromatography for both, noble metal nanoparticle assessment and sensitive plasmon…
2021
Abstract Colorimetric localized surface plasmon resonance (LSPR) as analytical response is applied for a wide number of chemical sensors and biosensors. However, the dependence of different factors, such as size distribution of nanoparticles (NPs), shape, dielectric environment, inter-particle distance and matrix, among others, can provide non-reliable results by UV–vis spectrometry in complex matrices if NP assessment is not carried out, particularly at low levels of analyte concentrations. Miniaturized liquid chromatography, capillary (CapLC) and nano (NanoLC), coupled on line with in-tube solid phase microextraction (IT-SPME) is proposed for the first time for both, controlling suitabili…
In-tube solid-phase microextraction-capillary liquid chromatography as a solution for the screening analysis of organophosphorus pesticides in untrea…
2006
This paper describes a method for the selective screening of organophosphorus pesticides in water. In-tube solid-phase microextraction (SPME) in an open capillary column coupled to capillary liquid chromatography (LC) with UV detection has been used to effect preconcentration, separation and detection of the analytes in the same assembly. For in-tube SPME two capillary columns of the same length and different internal diameters and coating thicknesses have been tested and compared, a 30 cm x 0.25 mm I.D., 0.25 micro m thickness coating column, and a 30 cm x 0.1 mm I.D., 0.1 micro m of coating thickness column. In both columns the coating was 95% dimethylpolysiloxane (PDMS)-5% diphenylpolysi…
Validation of a confirmatory method for the determination of macrolides in liver and kidney animal tissues in accordance with the European Union regu…
2006
Abstract This study proposes a simple multiresidue liquid chromatography–diode array detector (LC–DAD) method capable of determining seven macrolide antibiotics in samples of liver and kidney animals at concentrations lower than those allowed by current legislation. Samples were prepared by homogenizing the tissue with EDTA–McIlvaine's buffer and extracted with an Oasis HLB cartridge. The consumption of organic solvent during extraction was minimum. The analytes were detected by LC–DAD and also by liquid chromatography–mass spectrometry with electrospray ionization (LC–(ESI)MS). The method was specific, stable and robust enough for the required purposes. The DAD method was validated in acco…
o-Phthalaldehyde–N-acetylcysteine polyamine derivatives: formation and stability in solution and in C18 supports
2001
A comparative study of different derivatization procedures has been performed in order to improve the stability of the reaction products o-phthalaldehyde-N-acetylcysteine (OPA-NAC) polyamines. Procedures such as solution derivatization, solution derivatization followed by retention on a packing support, derivatization on different packing supports and on-column derivatization, have been optimized and compared. The degradation rate constant (k) of the derivative was dependent on the procedure used and on the analyte. For the spermine (the most unstable isoindol tested) k was 8 +/- 2 x 10(-2) min(-1) in solution versus 7.7 +/- 1.1 x 10(-4) min(-1) on the (C18) solid support. The results obtai…
Green aspects, developments and perspectives of liquid phase microextraction techniques.
2014
Determination of analytes at trace levels in complex samples (e.g. biological or contaminated water or soils) are often required for the environmental assessment and monitoring as well as for scientific research in the field of environmental pollution. A limited number of analytical techniques are sensitive enough for the direct determination of trace components in samples and, because of that, a preliminary step of the analyte isolation/enrichment prior to analysis is required in many cases. In this work the newest trends and innovations in liquid phase microextraction, like: single-drop microextraction (SDME), hollow fiber liquid-phase microextraction (HF-LPME), and dispersive liquid-liqu…
Determination of aliphatic amines in water by liquid chromatography using solid-phase extraction cartridges for preconcentration and derivatization
2001
Bond Elut C18 solid-phase extraction cartridges were used for preconcentration and pre-column derivatization with 3,5-dinitrobenzoyl chloride (DNB) of aliphatic amines in water. Conditions for analyte preconcentration and derivatization (including the volume of sample, concentration of reagent, time of reaction and pH) were investigated, using ethylamine, isopropylamine and dimethylamine as model compounds. On the basis of these studies, a rapid and sensitive method for the determination of aliphatic amines in water is presented. The analytes are retained and purified on the cartridges and then derivatized and desorbed by drawing in succession the DNB solution and acetonitrile. The collecte…
Application of solid-phase microextraction combined with derivatization to the enantiomeric determination of amphetamines.
2005
Abstract The utility of combining chiral derivatization and solid-phase microextraction (SPME) for the enantiomeric analysis of primary amphetamines by liquid chromatography has been investigated. Different derivatization/extraction strategies have been evaluated and compared using the chiral reagent o -phthaldialdehyde (OPA)– N -acetyl- l -cysteine (NAC) and fibres with a Carbowax-templated resin coating. Amphetamine, norephedrine and 3,4-methylenedioxyamphetamine (MDA) were used as model compounds. On the basis of the results obtained, a new method is presented based on the derivatization of the analytes in solution followed by SPME of the OPA–NAC derivatives formed. The proposed conditio…
Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.
2017
A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to b…
Analytical strategies to determine quinolone residues in food and the environment
2007
23 páginas, 5 figuras, 5 tablas.
Development of a selective solid phase extraction method for nitro musk compounds in environmental waters using a molecularly imprinted sorbent
2013
A powerful analytical method for the determination of the family of the nitro musk compounds at trace level in environmental waters-river, sea, and water from a treatment plant-is presented. The method is based on the use of molecularly imprinted silica (MIS) as sorbent for solid phase extraction (SPE) used for the clean-up and the concentration step of the target analytes previous to their determination by gas chromatography-mass spectrometry. The optimized extraction procedure allowed extraction recoveries between 61% and 87% using the MIS. The comparison with a non-imprinted silica (NIS) sorbent, for which extraction recoveries between 8% and 26% were obtained, showed the high selectivit…