Search results for "Sonication"
showing 10 items of 85 documents
Conformational transitions of gramicidin A in phospholipid model membranes. A high-performance liquid chromatography assessment.
1991
We have investigated the conformation of gramicidin A reconstituted in different phospholipid environments, small unilamellar vesicles, extensive bilayers, and micelles by exploiting a recently proposed experimental approach based on high-performance liquid chromatography [Bano et al. (1988) J. Chromatogr. 458, 105; Bano et al. (1989) FEBS Lett. 250, 67]. The method allows the separation of conformational species of the peptide namely, antiparallel double-stranded (APDS) dimers and β 6.3 -helical monomers, and quantitation of their proportions in the lipid environment. Various experimental parameters (e.g., nature of organic solvent, time of incubation in organic solvent, lipid-to-peptide m…
Soil remediation: humic acids as natural surfactants in the washings of highly contaminated soils
2005
The remediation of the highly contaminated site around the former chemical plant of ACNA (near Savona) in Northern Italy is a top priority in Italy. The aim of the present work was to contribute in finding innovative and environmental-friendly technology to remediate soils from the ACNA contaminated site. Two soils sampled from the ACNA site (A and B), differing in texture and amount and type of organic contaminants, were subjected to soil washings by comparing the removal efficiency of water, two synthetic surfactants, sodium dodecylsulphate (SDS) and Triton X-100 (TX100), and a solution of a natural surfactant, a humic acid (HA) at its critical micelle concentration (CMC). The extraction …
First‐Derivative Fourier‐Transform Infrared Determination of Oxadiazon in Commercial Herbicide Formulations
2008
Abstract A Fourier‐transform infrared (FTIR) method has been developed for the quantification of oxadiazon in herbicide formulations. The method involves the extraction of the active ingredient by sonication of the samples with CHCl3 and direct measurement of the peak area values in first‐order derivate spectra from 1770 cm−1 to 1774 cm−1 corrected with a baseline point located at 1950 cm−1 and after a 5‐point smoothing. A limit of detection (3 s) of 0.03 mg g−1 and a typical relative standard deviation (RSD) of 1.3% were found. Results obtained were comparable with those found by liquid chromatography with UV detection. The proposed method involves a 7‐times reduction in solvent consumptio…
Analysis of LSD in human body fluids and hair samples applying ImmunElute columns.
2000
Immunoaffinity extraction units (LSD ImmunElute) are commercially available for the analysis of lysergic acid diethylamide (LSD) in urine. The ImmunElute resin contains immobilized monoclonal antibodies to LSD. We applied the ImmunElute procedure to serum and also to human hair samples. For hair analysis the samples were first extracted with methanol under sonication. The extracts were then purified using the ImmunElute resin. LSD analysis was carried out with HPLC and fluorescence detection. The immunoaffinity extraction provides highly purified extracts for chromatographic analysis. The limit of detection (signal-to-noise ratio = 3) has been determined to be < 50 pg regardless of which sa…
Non-chromatographic speciation of toxic arsenic in vegetables by hydride generation-atomic fluorescence spectrometry after ultrasound-assisted extrac…
2007
A non-chromatographic, sensitive and simple analytical method has been developed for the determination of toxic arsenic species in vegetable samples by hydride generation-atomic fluorescence spectrometry (HG-AFS). As(III), As(V), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were determined by hydride generation-atomic fluorescence spectrometry using a series of proportional equations. The method is based on a single extraction of the arsenic species considered from vegetables through sonication at room temperature with H(3)PO(4) 1 mol L(-1) in the presence of 0.1% (w/v) Triton XT-114 and washing of the solid phase with 0.1% (w/v) EDTA, followed by direct measurement of the co…
On-line speciation of mercury in fish by cold vapour atomic fluorescence through ultrasound-assisted extraction
2004
A fully mechanized procedure has been developed for the speciation of mercury in fish samples by using cold vapour atomic fluorescence spectrometry (CV-AFS). Sample slurries in an acid mixture in the presence of a surfactant and with traces of K2Cr2O7, were injected into a flow system, sonicated and merged with 1 ml of an oxidant mixture of KBr/KBrO3 heated at 50 °C in a water bath and total Hg determined by CV-AFS. Sonicated sample slurries were also measured, in the absence of KBr/KBrO3, in order to obtain a second series of data which could be employed to establish the concentrations of free Hg(II). Different compositions of the acidic extractant solutions were evaluated by mixing HCl, H…
Improvement of the electrophoretic protein profiles of Leguminosae gums extracts using gamanase and application to the evaluation of carob–guar mixtu…
2004
Abstract A quantitative assay for guar gum in carob gum, based on the extraction of proteins in acetonitrile–water (7:3), separation by capillary electrophoresis and multiple linear regression (MLR) using the areas of nine selected peaks as predictors, was improved by performing the extraction in the presence of gamanase. In the absence of the enzyme, peak migration times and areas depended on the guar content, which complicated peak identification and evaluation. Manual correction of the migration times by comparison with standard electropherograms obtained with pure carob and carob–guar mixtures was required; however, when the proteins were extracted under sonication at 60 °C for 30 min i…
Speciation of selenium and tellurium in milk by hydride generation atomic fluorescence spectrometry
2004
A simple, fast and highly sensitive method has been developed for the differentiation of Se and Te into their (IV) and (VI) oxidation states in milk samples by HG-AFS. This procedure involves a previous leaching of milk slurries by sonication with aqua regia for 10 min. Se(IV) and Te(IV) were determined by analysis of the samples without a pre-reduction step; being total Se and Te determined after reduction with KBr. The method provides limit of detection values (LOD) of 0.012 and 0.023 ng ml−1 for Se(IV) and Te(IV) respectively. Average relative standard deviation values of 10.5%, 3.9%, 12% and 12.5% were found for the determination of Se(IV), Se(VI), Te(IV) and Te(VI) in milk samples cont…
Non-chromatographic speciation analysis of arsenic and antimony in milk hydride generation atomic fluorescence spectrometry
2003
Abstract A rapid, high sensitivity method has been developed for the determination of As(III), As(V), Sb(III) and Sb(V) in milk samples by using hydride generation atomic fluorescence spectrometry. The method is based on the leaching of As and Sb from milk through the sonication of samples with aqua regia followed by direct determination of the corresponding hydrides both before and after reduction with KI. It was confirmed by recovery experiments on spiked commercially available samples that neither the reduced nor the oxidized forms of the elements under study or mixtures of the two oxidation states were modified by the room temperature sample treatment with aqua regia. The methodologies …
Multicommutation as an environmentally friendly analytical tool in the hydride generation atomic fluorescence determination of tellurium in milk.
2003
The aim of this study is to show the advantages of the emerging multicommutation methodology based on the use of solenoid valves for Te determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS). The delivery of a series of alternating sequential insertions of small volumes of samples and reagents gives rise to new hydrodynamic processes and exciting analytical potentials by controlling the time of flow through the on/off-switched solenoid valves. This drastically reduces the reagent consumption by a factor of 4 and the generation of effluents (590 mL h(-1) instead of 750 mL h(-1) generated by the continuous-mode measurement) and also provides an improvement in th…