Search results for "Sound"
showing 10 items of 1845 documents
Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Asso…
2018
This Consensus Document is the first of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The first document appraises the role of intracoronary imaging to guide percutaneous coronary interventions (PCIs) in clinical practice. Current evidence regarding the impact of intracoronary imaging guidance on cardiovascular outcomes is summarized, and patients or lesions most likely to derive clinical benefit from an imaging-guided intervention are identified. The relevance of the u…
Vaginal progesterone decreases preterm birth and neonatal morbidity and mortality in women with a twin gestation and a short cervix: an updated meta‐…
2017
Objective To assess the efficacy of vaginal progesterone for the prevention of preterm birth and neonatal morbidity and mortality in asymptomatic women with a twin gestation and a sonographic short cervix (cervical length ≤ 25 mm) in the mid-trimester. Methods This was an updated systematic review and meta-analysis of individual patient data (IPD) from randomized controlled trials comparing vaginal progesterone with placebo/no treatment in women with a twin gestation and a mid-trimester sonographic cervical length ≤ 25 mm. MEDLINE, EMBASE, POPLINE, CINAHL and LILACS (all from inception to 31 December 2016), the Cochrane Central Register of Controlled Trials, Research Registers of ongoing tr…
Untersuchungen �ber eine akute Wirkung von Trijodthyronin auf Refrakt�rzeit und Leitungsgeschwindigkeit des Meerschweinchenvorhofs
1962
Es wird uber die Untersuchung einer akuten Wirkung von T3 in vitro auf die Refraktarperiode und die Leitungsgeschwindigkeit des Meerschweinchenvorhofs berichtet. T3 verkurzte die Refraktarzeit geringfugig (5,2%). Bei vermindertem K-Gehalt der Badlosung oder nach Vorgabe von ACh oder DNP trat die Verkurzung der Refraktarzeit unter T3 wesentlich deutlicher in Erscheinung, und es konnte Flimmern ausgelost werden, obwohl die Substanzen vor der Gabe von T3 vollstandig ausgespult waren. Adrenalin hatte keinen Einflus auf den T3-Effekt. Die Leitungsgeschwindigkeit wurde durch T3 nicht verandert.
Influence of the suspension of continued treatment with flurazepam and amobarbital on two discrimination learning schedules.
1977
The authors have studied the effect of the suspension of chronic treatment with flurazepam and amobarbital on the operant behavior of rats that for the first time were in the presence of two fixed-interval discrimination schedules. With the sound discrimination schedule, the responses emitted by the treated animals had characteristics similar to those of control animals. With the temporal discrimination schedule, though it is not possible to distinguish between learning rates, modifications in the intensity of the effect (increases in lever pressing) indicate that, considering the doses, the action of flurazepam is slight and that of amobarbital clear and statistically significant.
Schallreaktionen bei Nachtfaltern
1949
Numerous Noctuides and Geometrides show quite mistakable reactions upon sound stimulations ranging from 10,000 to 20,0000 vib/sec (Hertz). The lowest limit range of perception seems to lie at 40,000 up to 80,000 vib/sec. The reactions of sitting or walking animals are instant movements of flight or catalepsy. Flying animals try evasion or stop their flight at once. Sleeping animals can not be roused by sound stimulation. There are no sound reactions if both tympani are pierced. The Noctuides and Geometrides seem to perceive the supersonic echolocation cries of bats by aid of their tympanal organs.
Photo-acoustic phase-delayed excitation of guided waves in coated bone phantoms
2013
Photo-acoustic skeletal quantitative ultrasound enables assessment of the fundamental flexural guided wave (FFGW) propagating in bone. This mode, consistent with the F(1,1) tube mode can now be measured through a coating of soft tissue. Interference due to ultrasound propagation in the soft tissue surrounding the bone is reduced by using phase-delayed ultrasound excitation. Photo-acoustic phase-delayed excitation was done on five axisymmetric bone phantoms (1-5 mm wall thickness), coated by a 5 mm thick soft-tissue mimicking layer. A fiber head comprising a linear array of four optical fibers (400 μm diameter), illuminated by pulsed laser diodes (905 nm wavelength) generated ultrasound. Thi…
Investigation of correction factors for non-reference conditions in ion chamber photon dosimetry with Monte-Carlo simulations.
2009
Current dosimetry protocols require geometrical reference conditions for the determination of absorbed dose in external radiotherapy. Whenever these geometrical conditions cannot be maintained the application of additional corrections becomes necessary, in principle. The current DIN6800-2 protocol includes a corresponding factor k(NR), but numerical values are lacking and no definite information about the magnitude of this correction is available yet. This study presents Monte-Carlo based calculations within the 6 MV-X photon field of a linear accelerator for a common used ion chamber (PTW31010) employing the EGSnrc code system. The linear accelerator model was matched to measurements, show…
Characterization of PTW-31015 PinPoint ionization chambers in photon and proton beams
2018
The increased use of complex forms of radiotherapy using small-field photon and proton beams has invoked a growing interest in the use of micro-ionization chambers. In this study, 48 PTW-TM31015 PinPoint-type micro-ionization chambers that are used in the commissioning and patient specific QA of a proton pencil beam scanning (PBS) delivery system have been characterized in proton and high-energy photon beams. In both beam modalities, the entire set of PinPoint chambers was characterized by imaging them, by evaluating their stability using check source measurements, by experimentally determining the ion recombination, polarity effect and by cross calibrating them in terms of absorbed dose to…
A Monte-Carlo based model of the AX-PET demonstrator and its experimental validation
2013
AX-PET is a novel PET detector based on axially oriented crystals and orthogonal wavelength shifter (WLS) strips, both individually read out by silicon photo-multipliers. Its design decouples sensitivity and spatial resolution, by reducing the parallax error due to the layered arrangement of the crystals. Additionally the granularity of AX-PET enhances the capability to track photons within the detector yielding a large fraction of inter-crystal scatter events. These events, if properly processed, can be included in the reconstruction stage further increasing the sensitivity. Its unique features require dedicated Monte-Carlo simulations, enabling the development of the device, interpreting …
Collision-kerma conversion between dose-to-tissue and dose-to-water by photon energy-fluence corrections in low-energy brachytherapy
2016
The AAPM TG-43 brachytherapy dosimetry formalism, introduced in 1995, has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations, except in the vicinity of the source capsule. Subsequent dosimetry developments, based on Monte Carlo calculations or analytical solutions of transport equations, do not rely on the CPE assumption and determine directly the dose to different tissues. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so tha…