Search results for "Sound"

showing 10 items of 1845 documents

Vortex density waves and high-frequency second sound in superfluid turbulence hydrodynamics

2010

In this paper we show that a recent hydrodynamical model of superfluid turbulence describes vortex density waves and their effects on the speed of high-frequency second sound. In this frequency regime, the vortex dynamics is not purely diffusive, as for low frequencies, but exhibits ondulatory features, whose influence on the second sound is here explored.

PhysicsNon-equilibrium thermodynamicsTurbulenceQuantum vortexFOS: Physical sciencesGeneral Physics and AstronomyNon-equilibrium thermodynamicsVorticityLiquid helium IISuperfluid turbulenceVortexCondensed Matter - Other Condensed MatterSuperfluidityClassical mechanicsSecond soundSettore MAT/07 - Fisica MatematicaSuperfluid helium-4Other Condensed Matter (cond-mat.other)
researchProduct

Neutrino propagation and spin zero sound in hot neutron matter with Skyrme interactions

1999

We present microscopic calculations of neutrino propagation in hot neutron matter above nuclear density within the framework of the Random Phase Approximation . Calculations are performed for non- degenerate neutrinos using various Skyrme effective interactions. We find that for densities just above nuclear density, spin zero sound is present at zero temperature for all Skyrme forces considered. However it disappears rapidly with increasing temperature due to a strong Landau damping. As a result the mean-free path is given, to a good approximation, by the mean field value. Because of the renormalization of the bare mass in the mean field, the medium is more transparent as compared to the fr…

PhysicsNuclear and High Energy PhysicsMean free pathBare massNuclear TheoryFOS: Physical sciencesFísicaZero soundHigh Energy Physics - PhenomenologyHigh Energy Physics - Phenomenology (hep-ph)Mean field theoryQuantum mechanicsQuantum electrodynamicsNeutronNeutrinoRandom phase approximationNuclear density
researchProduct

Enhancement of nucleon-nucleon cross section in sidewards flowing nuclear matter through zero sound mode excitation

1998

We investigate the modification induced on the nucleon-nucleon cross section by screening of the interaction inside nuclear matter. The interaction is described by the relativistic one boson exchange of $\sigma$, $\omega$ and $\pi$ mesons. Medium effects enter as loop corrections to the meson propagators and are characterized not only by density, but also by temperature and velocity with respect to the center of mass of the collision. The cross section displays peaks for some specific values of the velocity, corresponding to the excitation of zero-sound modes of the longitudinal $\omega$ field. The enhancement factor amounts to about 1.5 under reasonable conditions. It increases with densit…

PhysicsNuclear and High Energy PhysicsNuclear TheoryMesonNuclear TheoryFOS: Physical sciencesZero soundNuclear matterNuclear physicsNuclear Theory (nucl-th)Cross section (physics)Center of massNucleonNuclear ExperimentExcitationBoson
researchProduct

On the existence of higher waves in a layer of superfluid helium

1973

The two implicit equations that contain the dispersion laws of waves propagating in a He II layer of variable thickness are formally investigated for solutions that go beyond those associated with the layer modifications of first and second sound: A series of symmetric and antisymmetric layer modes are found to exist by calculating the distribution of roots of the dispersion equations in the complex wave number plane as a function of layer thickness and angular frequency. All these modes turn out to be strongly attenuated and can be regarded as layer modifications of the viscous wave. Phase velocities, attenuation coefficients, and velocity profiles of some of them are calculated numericall…

PhysicsNuclear and High Energy PhysicsWave propagationDispersion relationQuantum mechanicsSecond soundGroup velocityWavenumberMechanicsPhase velocityDispersion (water waves)Superfluid helium-4Zeitschrift für Physik A Hadrons and nuclei
researchProduct

Carbon fragmentation measurements and validation of the GEANT4 nuclear reaction models for hadrontherapy

2012

Nuclear fragmentation measurements are necessary when using heavy-ion beams in hadrontherapy to predict the effects of the ion nuclear interactions within the human body. Moreover, they are also fundamental to validate and improve the Monte Carlo codes for their use in planning tumor treatments. Nowadays, a very limited set of carbon fragmentation cross sections are being measured, and in particular, to our knowledge, no double-differential fragmentation cross sections at intermediate energies are available in the literature. In this work, we have measured the double-differential cross sections and the angular distributions of the secondary fragments produced in the (12)C fragmentation at 6…

PhysicsNuclear reactionRadiological and Ultrasound TechnologyHEAVY-ION REACTIONS; BEAM TRANSPORT; THERAPY;Monte Carlo methodBinary numberHeavy Ion RadiotherapyTHERAPYCarbonSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)IonNuclear physicsMolecular dynamicsFragmentation (mass spectrometry)CascadeHEAVY-ION REACTIONSHumansRadiology Nuclear Medicine and imagingNuclear ExperimentQuantumMonte Carlo MethodBEAM TRANSPORT
researchProduct

Electroweak baryogenesis at high bubble wall velocities

2020

It is widely believed that electroweak baryogenesis should be suppressed in strong phase transitions with fast-moving bubble walls, but this effect has never been quantitatively studied. We rederive fluid equations describing transport of particle asymmetries near the bubble wall without making the small-wall-velocity approximation. We show that the suppression of the baryon asymmetry is a smooth function of the wall speed and that there is no special behavior when crossing the sound speed barrier. Electroweak baryogenesis can thus be efficient also with strong detonations, generically associated with models with observably large gravitational waves. We also make a systematic and critical c…

PhysicsPhase transitionleptogenesis010308 nuclear & particles physicsGravitational waveBubbleastrofysiikkaElectroweak interactionHigh Energy Physics::Phenomenologybaryogenesishiukkasfysiikkakosmologia01 natural sciences114 Physical sciencesBaryogenesisPhysics::Fluid DynamicsBaryon asymmetryQuantum electrodynamicsSpeed of sound0103 physical sciences010306 general physicsVacuum expectation value
researchProduct

Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams.

2020

The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of…

PhysicsPhotonsPhotonRadiological and Ultrasound TechnologyMonte Carlo methodUncertaintyWater030218 nuclear medicine & medical imagingNuclear physics03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisIonizationAbsorbed doseIonization chamberRelative biological effectivenessDosimetryRadiology Nuclear Medicine and imagingLaser beam qualityRadiometryMonte Carlo MethodRelative Biological EffectivenessPhysics in medicine and biology
researchProduct

Monte Carlo study of microdosimetric diamond detectors

2015

Ion-beam therapy provides a high dose conformity and increased radiobiological effectiveness with respect to conventional radiation-therapy. Strict constraints on the maximum uncertainty on the biological weighted dose and consequently on the biological weighting factor require the determination of the radiation quality, defined as the types and energy spectra of the radiation at a specific point. However the experimental determination of radiation quality, in particular for an internal target, is not simple and the features of ion interactions and treatment delivery require dedicated and optimized detectors. Recently chemical vapor deposition (CVD) diamond detectors have been suggested as …

PhysicsPhotonsWork (thermodynamics)PhotonRadiological and Ultrasound Technologybusiness.industryDetectorMonte Carlo methodUncertaintyDiamondRadiationengineering.materialIonOpticsengineeringRadiometryRadiology Nuclear Medicine and imagingDiamondProtonsRadiometrybusinessMonte Carlo MethodPhysics in Medicine and Biology
researchProduct

Rashba spin-orbit-interaction-based quantum pump in graphene

2012

We present a proposal for an adiabatic quantum pump based on a graphene monolayer patterned by electrostatic gates and operated in the low-energy Dirac regime. The setup under investigation works in the presence of inhomogeneous spin-orbit interactions of intrinsic- and Rashba-type and allows to generate spin polarized coherent current. A local spin polarized current is induced by the pumping mechanism assisted by the spin-double refraction phenomenon.

PhysicsPhysics and Astronomy (miscellaneous)Condensed matter physicsCondensed Matter - Mesoscale and Nanoscale PhysicsGrapheneDirac (software)FOS: Physical sciencesPhysics::OpticsSpin–orbit interactionlaw.inventionlawMonolayerMesoscale and Nanoscale Physics (cond-mat.mes-hall)Refraction (sound)Condensed Matter::Strongly Correlated ElectronsAdiabatic processQuantumSpin-½
researchProduct

Monte Carlo calculation of dose rate distributions around the Walstam CDC.K-type137Cs sources

2001

Basic dosimetric data for the Walstam CDC.K-type low dose rate 137Cs sources in water have been calculated using Monte Carlo techniques. These sources, CDC.K1 -K3 and CDC.K4, are widely used in a range of applicators and moulds for the treatment of intracavitary and superficial cancers. Our purpose is to improve existing data about these sources using the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water have been calculated around these sources and are presented as conventional 2D Cartesian look-up tables. Also the AAPM Task Group 43 formalism for dose calculation has been applied. The calculated dose rate constant for the CDC.K1-K3 source is A = 1.106 +/- 0.001…

PhysicsPolynomial regressionModels StatisticalRadiological and Ultrasound TechnologyRadiotherapy Planning Computer-AssistedMonte Carlo methodSievert integrallaw.inventionComputational physicsCesium RadioisotopeslawAnisotropyHumansDosimetryRadiology Nuclear Medicine and imagingCartesian coordinate systemStatistical physicsLow dose rateRadiometryDose rateAnisotropyMonte Carlo MethodAlgorithmsSoftwarePhysics in Medicine and Biology
researchProduct