Search results for "Sound"
showing 10 items of 1845 documents
Thermodynamical derivation of a hydrodynamical model of inhomogeneous superfluid turbulence
2007
In this paper, we build up a thermodynamical model of inhomogeneous superfluid turbulence to describe vortex diffusion in inhomogeneous turbulent tangles, and a coupling between second sound and vortex-density waves. The theory chooses as fundamental fields the density, the velocity, the energy density, the heat flux, and the averaged vortex line length per unit volume. The restrictions on the constitutive quantities are deduced from the entropy principle, using the Liu method of Lagrange multipliers. Field equations are written and the wave propagation is studied with the aim to describe the mutual interactions between the second sound and the vortex tangle.
Second sound, superfluid turbulence, and intermittent effects in liquid helium II
2002
Kernel-based retrieval of atmospheric profiles from IASI data
2011
This paper proposes the use of kernel ridge regression (KRR) to derive surface and atmospheric properties from hyperspectral infrared sounding spectra. We focus on the retrieval of temperature and humidity atmospheric profiles from Infrared Atmospheric Sounding Interferometer (MetOp-IASI) data, and provide confidence maps on the predictions. In addition, we propose a scheme for the identification of anomalies by supervised classification of discrepancies with the ECMWF estimates. For the retrieval, we observed that KRR clearly outperformed linear regression. Looking at the confidence maps, we observed that big discrepancies are mainly due to the presence of clouds and low emissivities in de…
Determination of the object surface function by structured light: application to the study of spinal deformities.
1999
The projection of structured light is a technique frequently used to determine the surface shape of an object. In this paper, a new procedure is described that efficiently resolves the correspondence between the knots of the projected grid and those obtained on the object when the projection is made. The method is based on the use of three images of the projected grid. In two of them the grid is projected over a flat surface placed, respectively, before and behind the object; both images are used for calibration. In the third image the grid is projected over the object. It is not reliant on accurate determination of the camera and projector pair relative to the grid and object. Once the met…
Surface waves on cylindrical solids: numerical and experimental study.
2013
The use of Rayleigh waves enables the solution of several important inspection problems. Propagation of surface waves along straight boundaries has been properly studied but investigations about their propagation on cylindrical surfaces are not sufficient, despite they can be still of interest for NDE applications. It has been proved experimentally that a surface wave pulse suffers a phase shift during its propagation along a cylindrical surface. A numerical approach has been developed to efficiently study these effects for different materials, curvatures and frequencies. This study can help the scientific community to better understand the phenomenon, quite complex and not yet fully explor…
Deep Gaussian Processes for Geophysical Parameter Retrieval
2018
This paper introduces deep Gaussian processes (DGPs) for geophysical parameter retrieval. Unlike the standard full GP model, the DGP accounts for complicated (modular, hierarchical) processes, provides an efficient solution that scales well to large datasets, and improves prediction accuracy over standard full and sparse GP models. We give empirical evidence of performance for estimation of surface dew point temperature from infrared sounding data.
Trade between Sweden and Portugal in the Eighteenth Century : Assessing the Reliability of STRO Compared to Swedish and Portuguese Sources
2018
Intravascular ultrasound imaging of arterial wall architecture.
1992
Intravascular ultrasound (IVUS) is a promising new technique for assessing vascular morphology and structure. Controversy exists whether the three-layer appearance of the arterial wall correctly reflects the histologic structures of the intima, media, and adventitia. We performed an experimental study to clarify the three-layer appearance. The vessel wall architecture was analyzed by IVUS on eight different kinds of plastic cylinders, 24 normal blood vessels from pigs, and 59 human arterial segments. A distinct three-layer appearance was observed on all the plastic cylinders when the ultrasound beam was perpendicular to the wall. A three-layer appearance was also seen in the arterial wall, …
About Objective 3-D Analysis of Airway Geometry in Computerized Tomography
2008
The technology of multislice X-ray computed tomography (MSCT) provides volume data sets with approximately isotropic resolution, which permits a noninvasive 3-D measurement and quantification of airway geometry. In different diseases, like emphysema, chronic obstructive pulmonary disease (COPD), or cystic fribrosis, changes in lung parenchyma are associated with an increase in airway wall thickness. In this paper, we describe an objective measuring method of the airway geometry in the 3-D space. The limited spatial resolution of clinical CT scanners in comparison to thin structures like airway walls causes difficulties in the measurement of the density and the thickness of these structures.…
Analysis of discrete and continuous distributions of ventilatory time constants from dynamic computed tomography.
2005
In this study, an algorithm was developed to measure the distribution of pulmonary time constants (TCs) from dynamic computed tomography (CT) data sets during a sudden airway pressure step up. Simulations with synthetic data were performed to test the methodology as well as the influence of experimental noise. Furthermore the algorithm was applied to in vivo data. In five pigs sudden changes in airway pressure were imposed during dynamic CT acquisition in healthy lungs and in a saline lavage ARDS model. The fractional gas content in the imaged slice (FGC) was calculated by density measurements for each CT image. Temporal variations of the FGC were analysed assuming a model with a continuous…