Search results for "Sound"

showing 10 items of 1845 documents

Cardiovascular magnetic resonance-derived aortic compliance, distensibility and pulse wave velocity at rest and during a supine bicycle exercise in y…

2014

Background Purpose: Risk of aortic rupture is evaluated based on the vessel diameter; this parameter is probably insufficient. In vivo evaluation of biomechanical property of the aortic tissue might be of interest to discriminate between normal and altered aortic tissue (A Lalande et al, JMRI 2008). The purpose of this study was to describe a technique to measure regional aortic compliance (AC), aortic distensibility (AD) and aortic stiffness with 1.5 T MRI in young individuals under resting conditions and during supine bicycle exercise.

medicine.medical_specialtySupine position[INFO.INFO-IM] Computer Science [cs]/Medical Imaging030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineInternal medicinemedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingRadiology Nuclear Medicine and imagingYoung adultAortic rupturePulse wave velocityComputingMilieux_MISCELLANEOUSAngiologyMedicine(all)Radiological and Ultrasound Technologymedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryMagnetic resonance imagingCompliance (physiology)Poster Presentationcardiovascular systemCardiologyAortic stiffnessCardiology and Cardiovascular Medicinebusiness
researchProduct

Plain film, CT and MRI sensibility in the evaluation of intraorbital foreign bodies in an in vitro model of the orbit and in pig eyes.

2000

Detection and characterization of intraorbital foreign bodies (IFB) is fundamental in acute trauma setting, preventing inflammatory sequelae or complications related to IFB movements when a MRI study is planned. Papers concerning plain film and CT sensibility in IFB detection show controversial results. For this reason we investigated plain film, CT and MRI sensibility in the evaluation of IFB. For an in vitro model, specimens of dry and fresh wood, glass, iron, plastic and graphite were immersed in animal lard and in a 0.9 % sodium chloride plus 3.5 g/dl human serum albumin solution. Specimens of different size and nature where also implanted into enucleated pig eyes. Air bubbles were intr…

medicine.medical_specialtySwineRadiodensityRadiographyPlain filmEyeSensitivity and SpecificityIn vitro modelmedicineAnimalsHumansRadiology Nuclear Medicine and imagingmedicine.diagnostic_testbusiness.industryUltrasoundMagnetic resonance imagingGeneral MedicineMagnetic Resonance ImagingEye Injuries Penetratingmedicine.anatomical_structureEye Foreign BodiesTomographyRadiologybusinessTomography X-Ray ComputedOrbitOrbit (anatomy)European radiology
researchProduct

Modulation of central corneal thickness by various riboflavin eyedrop compositions in porcine corneas

2012

Purpose To evaluate the modulatory effect of various riboflavin 0.1% and 0.2% compositions on the central corneal thickness (CCT) in fresh porcine corneas. Setting Department of Ophthalmology, Johannes Gutenberg University of Mainz, Mainz, Germany. Design Experimental study. Methods The CCT in freshly enucleated porcine globes was measured by ultrasound pachymetry before and after (if applicable) deepithelialization and every 10 minutes thereafter during 120 minutes of eyedrop application. In Groups 1 and 2 (controls), no eyedrops were applied. In Groups 3 and 4, isotonic riboflavin eyedrops were used. In Groups 5 to 9, hypotonic riboflavin eyedrops were given. In Groups 10 and 11, preparat…

medicine.medical_specialtySwineRiboflavinRiboflavinCorneaCorneal edemaCorneaOphthalmologyIsotonicAnimalsMedicineBody Weights and MeasuresUltrasonographyPhotosensitizing Agentsbusiness.industryCorneal EdemaOsmolar ConcentrationUltrasound pachymetryHydrogen-Ion ConcentrationSensory SystemsSurgeryOphthalmologyCross-Linking ReagentsOphthalmic solutionsmedicine.anatomical_structurePhotochemotherapySurgeryOphthalmic SolutionsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Predictors of testicular viability in testicular torsion

2007

Abstract Aim Testicular torsion (TT) requires prompt diagnosis and treatment to avoid testicular loss. Most studies have focused on the ideal work up to rule TT out in cases of acute scrotum. We attempted here to define objective criteria to select between orchidopexy and orchidectomy in patients undergoing surgery for TT. Patients and methods Fifteen boys with a median age at presentation of 7.8 (range 6.4–12) years undergoing surgical treatment for TT underwent color-Doppler ultrasound (CDU) preoperatively, and a bleeding test intraoperatively. Duration of preoperative history, degree of torsion, CDU findings and degree of bleeding were analyzed. Results Salvageability was independent of …

medicine.medical_specialtyTesticular torsion; Orchidectomy; Doppler ultrasound; Atrophy; ChildrenTesticular torsionTesticular atrophybusiness.industryUrologyUltrasoundUrologyTesticleOrchidectomymedicine.diseaseDoppler ultrasoundWork-upSurgerymedicine.anatomical_structureAtrophyPediatrics Perinatology and Child HealthmedicineTesticular torsionIn patientAtrophybusinessSurgical treatmentChildren
researchProduct

Ultrasound-guided spinal fracture repositioning

1998

The management of narrowing spinal fragments in the operative treatment of spinal fractures remains an open question, in particular when the procedure is performed by a posterior approach. This article describes the use of intraoperative ultrasonography during spinal surgery. From 1990 to 1997, 116 spinal fractures were treated operatively at our clinic. Stabilization of the spine was achieved with the AO fixateur interne and the AO USS, respectively (Synthes, D-79224, Umkirch, Germany). For 60 cases who had a fractured posterior vertebral surface dislocated into the spinal canal, we used intraoperative ultrasonography to monitor the repositioning of the narrowing fragments. The patients un…

medicine.medical_specialtyThoracic VertebraePosterior approachIntraoperative ultrasoundFracture Fixation InternalIntraoperative PeriodSpinal StenosisSpinal fractureHumansMedicineSpinal canalRachisRetrospective StudiesUltrasonography Doppler DuplexLumbar VertebraeSpinalisbusiness.industryReproducibility of Resultsmedicine.diseaseUltrasound guidedmedicine.anatomical_structureSpinal FracturesSurgeryRadiologyTomography X-Ray ComputedbusinessSpinal CanalAbdominal surgerySurgical Endoscopy
researchProduct

Three-dimensional ultrasound evaluation in the head and neck.

1998

We evaluated the use of a novel three-dimensional ultrasound imaging device in patients with various head and neck lesions. The investigated system was found to be a valuable adjunct to conventional ultrasound in head and neck evaluations. A disadvantage of the three-dimensional system was the need for expensive technical equipment.

medicine.medical_specialtyThree dimensional ultrasoundbusiness.industryConventional ultrasound03 medical and health sciences0302 clinical medicineOtorhinolaryngologyOtorhinolaryngologyHead and Neck Neoplasms030220 oncology & carcinogenesisUltrasound imagingMedicineHumansSurgeryIn patientRadiologyProspective Studies030223 otorhinolaryngologybusinessHead and neckUltrasonographyOtolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery
researchProduct

Value of routine abdominal and lymph node sonography in the follow-up of breast cancer patients.

1994

Abstract Objective: The aim of this study was to review usefulness and intervals for abdominal sonography during the follow-up of breast cancer patients. Additionally, we assessed the value of regional lymph node sonography in patients with possible locoregional recurrence. Subjects: Retrospectively, 2657 abdominal ultrasound examinations of 414 patients and 299 sonographic examinations of the regional lymph nodes in 227 patients after surgical treatment for breast cancer were evaluated. Results: Follow-up abdominal sonography revealed metastases in 6.8% of patients, and in 1% of examinations. There was no dependence on the initial T- or N-stage. At sonography of the regional lymph nodes in…

medicine.medical_specialtyTime FactorsAbdominal ultrasoundMammary glandBreast NeoplasmsSensitivity and SpecificityBreast cancermedicineHumansRadiology Nuclear Medicine and imagingIn patientLymph nodeNeoplasm StagingRetrospective StudiesUltrasonographybusiness.industryIncidenceRetrospective cohort studyGeneral Medicinemedicine.diseasemedicine.anatomical_structureAbdominal NeoplasmsLymphatic MetastasisAbdomenFemaleLymphRadiologyLymph NodesbusinessFollow-Up StudiesEuropean journal of radiology
researchProduct

Low-frequency ultrasound induces nonenzymatic thrombolysis in vitro.

2002

To evaluate whether ultrasound, applied over a distance of several centimeters and in the absence of thrombolytic agents, may have a thrombolytic effect on blood clots.Low-frequency (20 kHz) continuous wave ultrasound at different intensity levels (0.15-1.2 W/cm2) and exposure times (5, 10, and 20 minutes) was assessed for its potential to induce thrombolysis of fresh human blood clots. The ultrasound effect was also studied in combination with recombinant tissue-type plasminogen activator-mediated thrombolysis. Experiments were carried out in a flow model in degassed sodium phosphate buffer at 37 degrees C at a distance of 3 cm from the ultrasonic probe to the blood clots. Regardless of ul…

medicine.medical_specialtyTime FactorsRadiological and Ultrasound Technologybusiness.industrymedicine.medical_treatmentUltrasonic TherapyUltrasoundHemodynamicsThrombolysismedicine.diseaseThrombosisRecombinant ProteinsSurgeryThrombolytic drugTissue Plasminogen ActivatorFibrinolysismedicineThrombolytic AgentHumansRadiology Nuclear Medicine and imagingThrombolytic TherapybusinessNuclear medicinePlasminogen activatorJournal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
researchProduct

Learning curve for piezosurgery in well-trained otological surgeons

2009

Abstract Objective Piezosurgery is an ultrasound instrument (24.7-29.5 kHz) capable of cutting bone without necrosis and nonmineralized tissue damage. The aim of this work has been to determine the time required for a well-trained surgeon to perform otological surgery with the piezoelectric device. Study Design Case series with planned data collection. Sixty-three patients affected by otosclerosis and 63 by chronic otitis media were enrolled. For each disease, patients were divided into three numerically equal groups, with each group assigned to a well-trained otological surgeon. Patients underwent stapedotomy (n = 63) and intact canal wall tympanoplasty (n = 63) with the piezoelectric devi…

medicine.medical_specialtyTime Factorsmedicine.medical_treatmentUltrasonic TherapypiezosurgeryOtoacoustic emissionOsteotomyotologic surgerymedicineTrainingHumanspiezosurgery otologic surgeryChronic otitis mediaPiezosurgeryPiezosurgery; Otosclerosis; Chronic otitis media; Training; Surgerymedicine.diagnostic_testbusiness.industrypiezosurgery; otologic surgeryUltrasoundEquipment DesignTympanometryTympanoplastymedicine.diseaseSurgeryOtitis MediaSettore MED/31 - OtorinolaringoiatriaOtosclerosisOtorhinolaryngologyOtosclerosisSurgeryAudiometrybusiness
researchProduct

Ultrasound observation of tissue fluid infiltration causing stridor in a woman undergoing shoulder arthroscopy

2012

Respiratory stridor developed rapidly during an interscalene brachial plexus block for shoulder arthroscopy in an obese woman. Extensive cervicothoracic edema due to tissue diffusion of the arthroscopic fluid was suspected. The outcome of patient after conservative management was satisfactory. We give a brief review of how this complication develops, the ultrasound findings, and briefly discuss similar cases.

medicine.medical_specialtyTissue fluidStridorCritical Care and Intensive Care MedicineArthroscopyEdemamedicineEdemaHumansRespiratory SoundsUltrasonographyShoulder arthroscopyShoulder JointInterscalene brachial plexus blockbusiness.industryUltrasoundMiddle Agedmedicine.diseaseSurgeryAnesthesiology and Pain MedicineFemalemedicine.symptomComplicationbusinessInfiltration (medical)NeckRevista Española de Anestesiología y Reanimación
researchProduct