Search results for "Sound"
showing 10 items of 1845 documents
Imaging findings of primary breast sarcoma : results of a first multicenter study
2016
Abstract Purpose To investigate imaging findings in patients with primary breast sarcoma (PBS). Materials and methods A retrospective search in the databases of 10 radiological departments in Germany from 2000 to 2011 was performed. Only histologically proven cases of PBS were included into the study. Mammography was available in 31 patients (33 lesions), ultrasound images in 24 patients (24 lesions), and for 10 patients (14 lesions) magnetic resonance imaging (MRI) of the breast was performed. The breast findings were classified according to the American College of Radiology Breast Imaging Reporting and Data Systems (BI-RADS) 5th edition categories. Collected data were evaluated by means o…
Early detection of embryonic malformations by transvaginal and color Doppler sonography.
1994
A total of 834 women with uneventful pregnancies were followed prospectively until the 15th week of gestation by TVS to screen for early embryonic malformations. Twenty-eight embryonic anomalies were detected in this series (3.3%). The median gestational age at diagnosis was 11 (range, 8 to 15) weeks. Two neural tube defects were missed by early TVS screening. Two suspected abdominal wall defects were not confirmed by repeat mid-second trimester abdominal sonography representing 6.7% of all fetal malformations evident by 24 weeks of gestation. The sensitivity and specificity of TVS screening for fetal malformations in this series were 93.3 and 99.7%, respectively. In addition, the role of T…
Organochlorine Compounds and Ultrasound Measurements of Fetal Growth in the INMA Cohort (Spain)
2014
This study was funded by grants from the EU (European Union): NEWGENERIS FP6-2003- Food-3-A-016320, FP7-ENV-2011 cod 282957, HEALTH.2010.2.4.5-1; and by grants from Spain: Instituto de Salud Carlos III (Red INMA G03/176, CB06/02/0031, and FIS-FEDER PI03/1615, PI04/1509, PI04/1112, PI04/1931, PI04/2018, PI04/1436, PI05/1079, PI05/1052, PI06/1213, PI07/0314, PI08/1151, PI09/02647, PI09/02311, PI11/01007, PI11/02591, PI11/02038, PI13/1944, PI13/02429, PI14/0891, PI14/1687, and Miguel Servet CP11/00178 and CP13/00054), Conselleria de Sanitat Generalitat Valenciana, Generalitat de Catalunya (CIRIT 1999SGR 00241), Diputación Foral de Guipúzcoa (DFG/004), Departamento de Sanidad y Consumo Gobierno…
Effect of an Endurance and Strength Mixed Circuit Training on Regional Fat Thickness: The Quest for the “Spot Reduction”
2021
Accumulation of adipose tissue in specific body areas is related to many physiological and hormonal variables. Spot reduction (SR) is a training protocol aimed to stimulate lipolysis locally, even though this training protocol has not been extensively studied in recent years. Thus, the present study sought to investigate the effect of a circuit-training SR on subcutaneous adipose tissue in healthy adults. Methods: Fourteen volunteers were randomly assigned to spot reduction (SR) or to a traditional resistance training (RT) protocol. Body composition via bioimpedance analysis (BIA) and subcutaneous adipose tissue via skinfold and ultrasound were measured before and after eight weeks of train…
Application of ultrasound in bone surgery: Two case reports
2010
The present study describes some of the applications of ultrasound in bone surgery, based on the presentation of two clinical cases. The Piezosurgery® ultrasound device was used (Tecnología Mectron Medical, Carasco, Italy). In one case the instrument was used to harvest a chin bone graft for placement in a bone defect at level 1.2, while in the other case a bony window osteotomy was made in the external wall of the maxillary sinus, in the context of a sinus membrane lift procedure. The Piezosurgery® device produces specific ultrasound frequency modulation (25-29 kHz), and has been designed to secure increased precision in application to bone surgery. This instrument produces selective secti…
Comparison of Lateral Abdominal Musculature Activation during Expiration with an Expiratory Flow Control Device Versus the Abdominal Drawing-in Maneu…
2020
Background and Objectives: The purpose of the present study was to quantify and compare lateral abdominal musculature thickness, including the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles, via rehabilitative ultrasound imaging (RUSI) during the use of the expiratory flow control device (EFCD) versus the classic abdominal drawing-in maneuver (ADIM). Materials and Methods: A cross-sectional observational pilot study. Twenty-one women were recruited and assessed the thickness of each muscle (TrA, IO, and EO) by ultrasound imaging at rest, during the ADIM, and during expiration with the EFCD. Waist circumference was also measured under the same circumstan…
Confounding factors of transvaginal ultrasound accuracy in endometrial cancer.
2020
Endometrial cancer is the most frequently diagnosed gynecological tumour. Transvaginal ultrasound has a leading role in the preoperative evaluation of endometrial cancer patients. The study aimed to identify factors that can worsen the diagnostic accuracy of transvaginal ultrasound in endometrial cancer patients. We retrospectively analysed 290 patients with histological diagnosis of endometrial adenocarcinoma. Two-dimensional (2D) gray-scale ultrasound and power Doppler imaging were performed. Age, menopause status, obesity, parity, Figo stage and benign uterine disorders were evaluated as possible factors worsening the diagnostic accuracy of the ultrasonography. FIGO stage IB was the main…
The negative predictive value of cervical interleukin-6 for the risk assessment of preterm birth.
2013
To determine the potential clinical use of cervical interleukin-6 (IL-6) as a negative predictor of preterm birth in symptomatic women.Observational prospective study carried out in a tertiary hospital.We studied 100 singleton pregnant women with threatened preterm delivery and intact membranes, between 24 and 34 weeks, recruited during the period 2006-2008. A cervical swab for IL-6 detection was taken and a transvaginal ultrasound scan was performed for measuring the cervical length.Five women delivered within 2 d and six women within 7 d. A high cervical IL-6 concentration was found in these women. The area under the ROC curve for cervical IL-6 was 0.97 for deliveries within 2 d after the…
Is avoidance of surgery possible in patients with perimenopausal ovarian tumors using transvaginal ultrasound and duplex color Doppler sonography?
1993
A total of 108 cases of small perimenopausal ovarian tumors (largest diameter, less than 7 cm) were evaluated by transvaginal sonography and duplex color Doppler sonography; 101 had criteria for benignity and 7 for malignancy. All cysts were punctured and aspirated to avoid unnecessary surgery (benign cases) and establish the cytologic diagnosis as well as to avoid the risk of leakage (malignant cases). Recurrence rate of benign punctured cysts was 25% within 1 year of follow up. No difference in recurrent rate was seen between pre- and postmenopausal patients (19 of 56 cases in the premenopausal group, and five of 28 cases in the postmenopausal group). The larger the cyst, the greater the …
Imaging of sarcopenia.
2016
Sarcopenia is currently considered a geriatric syndrome increasing in older people. The consequences of sarcopenia – in terms of impaired mobility, limited self-sufficiency and disability – have been amply demonstrated, increasing the need to develop methods to identify muscle mass loss as early as possible. Although sarcopenia involves a reduction in both muscle mass and function, loss of muscle mass remains the essential criterion for diagnosing this condition in daily practice. Computed tomography and magnetic resonance imaging represent the gold standard for studying body composition, and can identify quantitative and qualitative changes in muscle mass. These techniques are costly, time…