Search results for "Sparging"
showing 10 items of 16 documents
Magnetic field control of gas-liquid mass transfer in ferrofluids
2020
Abstract Gas-liquid mass transfer plays a key role in a broad range of industrial processes. The magnetic field control over the morphology of the gas-liquid interface and solute transport is an attractive feature if it can be realized efficiently. However, the magnetic properties of typical liquids and gases are rather weak. The experimental investigation is carried out to evaluate the effect of the magnetic field, which is mediated by magnetic nanoparticles, on the gas-liquid mass exchange during the sparging run through a hydrocarbon ferrofluid. The results indicate that the gradient field is especially effective at controlling the gas-liquid contact volume: the foaming of the liquid dur…
Impact of anaerobic dynamic membrane bioreactor configuration on treatment and filterability performance
2017
Abstract Submerged and external anaerobic dynamic membrane bioreactors (AnDMBRs) have been compared in terms of removal efficiency, filtration characteristics and microbial community structure. High COD removal efficiencies were obtained with both submerged and external AnDMBRs. To obtain an effective dynamic membrane (DM) layer enabling high quality permeate, longer time was required in the external AnDMBR configuration compared to the submerged one. A difference in microbial community structure was identified using pyrosequencing analyses between the submerged and external AnDMBRs. The number of archaeal types decreased in the bulk sludge of the external AnDMBR. External sludge recirculat…
Instrumentation, control, and automation for submerged anaerobic membrane bioreactors
2015
A submerged anaerobic membrane bioreactor (AnMBR) demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON® , Koch Membrane Systems, PUR-PSH31) was designed and operated for urban wastewater treatment. An instrumentation, control, and automation (ICA) system was designed and implemented for proper process performance. Several single-input-single-output (SISO) feedback control loops based on conventional on off and PID algorithms were implemented to control the following operating variables: flow-rates (influent, permeate, sludge recycling and wasting, and recycled biogas through both reactor and membrane tanks), sludge wasting volume, temperature, transmembrane pr…
Mathematical modelling of filtration in submerged anaerobic MBRs (SAnMBRs): long-term validation
2013
The aim of this study was the long-term validation of a model capable of reproducing the filtration process occurring in a submerged anaerobic membrane bioreactor (SAnMBR) system. The proposed model was validated using data obtained horn a SAnMBR demonstration plant fitted with industrial-scale hollow-fibre membranes. The validation was carried out using both lightly and heavily fouled membranes operating at different bulk concentrations, gas sparging intensities and transmembrane fluxes. Across a broad spectrum of operating conditions, the model correctly forecast the respective experimental data in the long term. The simulation results revealed the importance of controlling irreversible f…
Sub-critical filtration conditions of commercial hollow-fibre membranes in a submerged anaerobic MBR (HF-SAnMBR) system: The effect of gas sparging i…
2012
A submerged anaerobic MBR demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON®, Koch Membrane Systems, PUR-PSH31) was operated using municipal wastewater at high levels of mixed liquor total solids (MLTS) (above 22gL -1). A modified flux-step method was applied to assess the critical flux (J C) at different gas sparging intensities. The results showed a linear dependency between J C and the specific gas demand per unit of membrane area (SGD m). J C ranged from 12 to 19LMH at SGD m values of between 0.17 and 0.5Nm 3h -1m -2, which are quite low in comparison to aerobic MBR. Long-term trials showed that the membranes operated steadily at fluxes close to the est…
Gas-lift anaerobic dynamic membrane bioreactors for high strength synthetic wastewater treatment: Effect of biogas sparging velocity and HRT on treat…
2016
Abstract A laboratory scale external anaerobic dynamic membrane bioreactor (AnDMBR) treating high strength wastewater (influent COD ≈ 20 g/L) was operated to assess the effect of biogas sparging velocity (GSV) and hydraulic retention time (HRT) on removal efficiency and dynamic membrane (DM) filtration characteristics. An increase in GSV resulted in a decrease in DM filtration resistance. DM or cake layer was identified as the main contributor to the total filtration resistance. The external AnDMBR achieved over 99% COD removal efficiency irrespective of the GSV. The results showed that the DM formation process proceeded until a stable cake layer was reached. Reducing of HRT resulted in an …
Model-based automatic tuning of a filtration control system for submerged anaerobic membrane bioreactors (AnMBR)
2014
This paper describes a model-based method to optimise filtration in submerged AnMBRs. The method is applied to an advanced knowledge-based control system and considers three statistical methods: (1) sensitivity analysis (Morris screening method) to identify an input subset for the advanced controller; (2) Monte Carlo method (trajectory-based random sampling) to find suitable initial values for the control inputs; and (3) optimisation algorithm (performing as a supervisory controller) to re-calibrate these control inputs in order to minimise plant operating costs. The model-based supervisory controller proposed allowed filtration to be optimised with low computational demands (about 5min). E…
Outdoor flat-panel membrane photobioreactor to treat the effluent of an anaerobic membrane bioreactor. Influence of operating, design, and environmen…
2018
[EN] As microalgae have the ability to simultaneously remove nutrients from wastewater streams while producing valuable biomass, microalgae-based wastewater treatment is a win-win strategy. Although recent advances have been made in this field in lab conditions, the transition to outdoor conditions on an industrial scale must be further investigated. In this work an outdoor pilot-scale membrane photobioreactor plant was operated for tertiary sewage treatment. The effects of different parameters on microalgae performance were studied including: temperature, light irradiance (solar and artificial irradiance), hydraulic retention time (HRT), biomass retention time (BRT), air sparging system an…
Factors that affect the permeability of commercial hollow-fibre membranes in a submerged anaerobic MBR (HF-SAnMBR) system
2013
A demonstration plant with two commercial HF ultrafiltration membrane modules (PURON (R), Koch Membrane Systems, PUR-PSH31) was operated with urban wastewater. The effect of the main operating variables on membrane performance at sub-critical and supracritical filtration conditions was tested. The physical operating variables that affected membrane performance most were gas sparging intensity and back-flush (BF) frequency. Indeed, low gas sparging intensities (around 0.23 Nm(3) h(-1) m(-2)) and low BF frequencies (30s back-flush for every 10 basic filtration relaxation cycles) were enough to enable membranes to be operated sub-critically even when levels of mixed liquor total solids were hi…
A filtration model applied to submerged anaerobic MBRs (SAnMBRs)
2013
The aim of this study was to develop a model able to correctly reproduce the filtration process of submerged anaerobic MBRs (SAnMBRs). The proposed model was calibrated and validated in a SAnMBR demonstration plant fitted with industrial-scale hollow-fibre membranes. Three suspended components were contemplated in the model: total solids concentration; dry mass of cake on the membrane surface; and dry mass of irreversible fouling on the membrane surface. The model addressed the following physical processes: the build-up and compression of the cake layer during filtration; cake layer removal using biogas sparging to scour the membrane; cake layer removal during back-flushing; and the consoli…