Search results for "Spatial"
showing 10 items of 2121 documents
Visuospatial attention lateralization in volleyball players and in rowers.
2011
In the present study, differences in visuospatial attention lateralization were evaluated in athletes engaged in open- compared to closed-skill sports and sedentary nonathletes. 23 volleyball players (open skill; Italian national level and regional level), 10 rowers (closed skill, Italian national level), and 23 sedentary participants responded to a computerized line-length judgment task. Five lines, differing in the length of their right and left segments, were randomly presented; the respondent made a forced-choice decision about the respective length of the two segments. Volleyball players responded significantly faster; those at the higher competitive level were also more accurate, mak…
Role of high-resolution ultrasonography without and with real-time spatial compound imaging in evaluating the injured posterior cruciate ligament: pr…
2009
This study sought to compare high-resolution ultrasonography (HRUS) without and with compound imaging in evaluating the injured posterior cruciate ligament (PCL). Thirteen patients with a magnetic resonance imaging (MRI) diagnosis of PCL lesions (ten acute and three chronic) and 20 healthy controls underwent conventional and compound HRUS performed by the same radiologist who was blinded to the subjects' case-control status. The PCL was scanned in a longitudinal direction in all cases. HRUS images were assessed for PCL thickness by two other radiologists blinded to the number and type of PCL injury. PCLs were classified as normal or injured, and the latter as having acute or chronic injurie…
Optokinetic stimulation affects temporal estimation in healthy humans
2007
The representation of time and space are closely linked in the cognitive system. Optokinetic stimulation modulates spatial attention in healthy subjects and patients with spatial neglect. In order to evaluate whether optokinetic stimulation could influence time perception, a group of healthy subjects performed "time-comparison" tasks of sub- and supra-second intervals before and after leftward or rightward optokinetic stimulation. Subjective time perception was biased by the direction of optokinetic stimulation. Rightward optokinetic stimulation induced an overestimation of time perception compared with baseline and leftward optokinetic stimulation. These results indicate a directional bias…
The Intracranial Distribution of Gliomas in Relation to Exposure From Mobile Phones: Analyses From the INTERPHONE Study
2016
When investigating the association between brain tumors and use of mobile telephones, accurate data on tumor position are essential, due to the highly localized absorption of energy in the human brain from the radio-frequency fields emitted. We used a point process model to investigate this association using information that included tumor localization data from the INTERPHONE Study (Australia, Canada, Denmark, Finland, France, Germany, Israel, Italy, Japan, New Zealand, Norway, Sweden, and the United Kingdom). Our main analysis included 792 regular mobile phone users diagnosed with a glioma between 2000 and 2004. Similar to earlier results, we found a statistically significant association …
The role of posterior parietal cortices on prismatic adaptation effects on the representation of time intervals
2013
Previous studies provided evidence of an ascending left-to-right spatial representation of time durations by using a technique affecting high levels of spatial cognition, i.e. prismatic adaptation (PA). Indeed, PA that induced a leftward aftereffect distorted time representation toward an underestimation, while PA that induced a rightward aftereffect distorted time representation toward an overestimation. The present study advances previous findings on the effects of PA on time by investigating the neural basis subtending these effects. We focused on the posterior parietal cortex (PPC) since it is involved in the PA procedure and also in the formulation of the spatial representation of time…
Choice of spatial frequency for contrast sensitivity evaluation after corneal refractive surgery.
2002
ABSTRACT PURPOSE: To study the utility of measurements of contrast sensitivity at different spatial frequencies as an index of visual recovery following refractive surgery. METHODS: Contrast sensitivity at 1.5, 3, 6, 12, and 18 c/deg was measured with the Stereo Optical FACT chart in 20 patients after photorefractive keratectomy (PRK) using the Nidek EC-5000 excimer laser system, and in 18 patients following laser in situ keratomileusis (LASER). Contrast sensitivity was measured preoperatively and 1, 3, 6, and 12 months after surgery. RESULTS: Results showed a statistically significant reduction (P<01) in contrast sensitivity at all spatial frequencies in PRR patients during the first an…
Neglect-like effects induced by tDCS modulation of posterior parietal cortices in healthy subjects
2011
Background Repetitive transcranial magnetic stimulation (rTMS) over right posterior parietal cortex was shown to induce interference on visuospatial perception in healthy subjects. Transcranial direct current stimulation (tDCS) is another noninvasive brain stimulation technique that works modulating cortical activity. It is applied through easy to use, noncostly, and portable devices. Objective/Hypothesis The aim of the current study was to investigate if the novel approach of “dual” stimulation over parietal cortices compared with the unilateral (right) cathodal one is able to induce greater and/or longer-lasting neglect-like effects in normal subjects performing a computerized visuospatia…
Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes.
2009
PURPOSE To determine the differences in refractive and visual results obtained in eyes with high and low myopia after multifocal intraocular lens (IOL) implantation. METHODS Monocular visual acuity for distance and near, with and without distance correction, and photopic and mesopic contrast sensitivity were measured at 6 months after surgery in 152 myopic eyes implanted with the AcrySof ReSTOR Natural (SN60D3) IOL. Two groups were created: high and low myopia (76 eyes in each). RESULTS Monocular best distance-corrected visual acuity was 0.02+/-0.06 logMAR for low myopes and 0.05+/-0.09 logMAR for high myopes. Monocular best distance-corrected near visual acuity was 0.04+/-0.05 and 0.07+/-0…
Comparison of the Behavioural Inattention Test and the Catherine Bergego Scale in assessment of hemispatial neglect.
2010
The objective of the study was to correlate visual and behavioural assessments of hemispatial neglect caused by cerebrovascular accident. We assessed 17 consecutive right-hemisphere stroke patients with hemispatial neglect: the Catherine Bergego Scale (CBS) was used to evaluate neglect in spontaneous behaviour and the conventional subtests of the Behavioural Inattention Test (BIT C) were used to assess visual neglect. The proportional severity of both visual and behavioural neglect was calculated in each individual patient. Dissociations were found between mild neglect in visual screening tasks and moderate or severe neglect in behaviour, although in most patients, neglect was equally evide…
Hemispatial neglect reflected on visual memory
2011
PURPOSE Recent studies of hemispatial neglect have revealed both lateralized and nonlateralized attention mechanisms contributing to the syndrome. In addition, neglect patients show impaired spatial working memory and diminished working memory capacity. The aim of this study was to investigate, how neglect would be reflected in their performances in commonly used clinical visual memory tests. METHODS Twelve patients with right hemisphere lesions and left neglect and twelve matched controls were assessed with the Behavioural Inattention Test, the visual reproduction of the WMS-R, the object memory test, the Rey figure test and the list learning test. Visuo-spatial span was explored with the …