Search results for "Specificity."

showing 10 items of 2232 documents

Reliability of the bright liver echo pattern in diagnosing steatosis in patients with cryptogenic and HCV-related hypertransaminasaemia.

2008

Aim To evaluate the reliability of the bright liver (BL) echo pattern on ultrasound to detect histological steatosis in chronic cryptogenic hypertransaminasaemia (CCH) and hepatitis C virus (HCV)-related forms of hypertransaminasaemia. Materials and methods One hundred and fifty patients, 54 with CCH and 96 with HCV hypertransaminasaemia (76 genotype 1/2 and 20 genotype 3), were enrolled. Histological steatosis was measured as the percentage of hepatocytes involved. The reliability of the BL sign was estimated using the sensitivity, specificity, positive and negative predictive values. Results Histological steatosis was present in 102/150 patients (68%) divided into 59/96 (62%) in the HCV g…

AdultMalemedicine.medical_specialtyHepatitis C virusHepacivirusmedicine.disease_causeGastroenterologySensitivity and SpecificityInternal medicineStatistical significanceGenotypemedicinePrevalenceHumansRadiology Nuclear Medicine and imagingProspective StudiesUltrasonography Doppler ColorTransaminasesHepatitis Chronicbiologybusiness.industryFatty liverGeneral MedicineHepatitis CMiddle Agedmedicine.diseasebiology.organism_classificationHepatitis CConfidence intervalFatty LiverItalyLiverHepatocytesFemalebright liver ultrasound steatosis cryptogenic hypertransaminasaemiaSteatosisbusinessBiomarkersClinical radiology
researchProduct

Detection of central pulmonary artery thromboemboli by transesophageal echocardiography in patients with severe pulmonary embolism.

1992

Transthoracic echocardiography generally provides only indirect signs of pulmonary embolism. In contrast, with transesophageal echocardiography the thromboembolus itself can be visualized in the central parts of the pulmonary artery. The aims of our study were to evaluate, first, the incidence of central pulmonary artery thromboemboli in patients with severe pulmonary embolism, and second, the accuracy of the echocardiographic diagnosis. Our study group comprised 60 patients with proved severe pulmonary embolism. All patients were examined by transthoracic and transesophageal echocardiography. The echocardiographic findings concerning the absence or presence of central pulmonary artery thro…

AdultMalemedicine.medical_specialtyHypertension PulmonaryBlood PressurePulmonary ArterySensitivity and SpecificityEsophagusInternal medicinemedicine.arteryThromboembolismmedicineHumansRadiology Nuclear Medicine and imagingIn patientProspective StudiesThrombusAgedbusiness.industryAngiography Digital SubtractionMiddle Agedmedicine.diseasePulmonary embolismEchocardiographyPulmonary arteryCardiologyFemaleRadiologyCardiology and Cardiovascular MedicinebusinessPulmonary EmbolismTomography X-Ray ComputedJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
researchProduct

Value of contrast-enhanced MR angiography and helical CT angiography in chronic thromboembolic pulmonary hypertension.

2003

The aim of this study was to evaluate the diagnostic value of contrast-enhanced MR angiography (ce MRA) and helical CT angiography (CTA) of the pulmonary arteries in the preoperative workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH). The ce MRA and CTA studies of 32 patients were included in this retrospective evaluation. Image quality was scored by two independent blinded observers. Data sets were assessed for number of patent segmental, subsegmental arteries, and number of vascular segments with thrombotic wall thickening, intraluminal webs, and abnormal proximal to distal tapering. Image quality for MRA/CTA was scored excellent in 16 of 16, good in 11 of 14, m…

AdultMalemedicine.medical_specialtyHypertension PulmonaryContrast MediaRisk AssessmentSensitivity and SpecificitySeverity of Illness IndexPredictive Value of TestsPreoperative CareMedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesNeuroradiologyAgedRetrospective StudiesThrombectomyPostoperative Caremedicine.diagnostic_testbusiness.industrymusculoskeletal neural and ocular physiologyUltrasoundInterventional radiologyGeneral MedicineMiddle Agedmedicine.diseaseThrombosiseye diseasesHelical ctRadiographic Image EnhancementTreatment OutcomePulmonary VeinsPredictive value of testsAngiographyChronic DiseaseChronic thromboembolic pulmonary hypertensionFemaleRadiologybusinessPulmonary EmbolismTomography Spiral Computedpsychological phenomena and processesMagnetic Resonance AngiographyFollow-Up StudiesEuropean radiology
researchProduct

Towards an international language for incontinence-associated dermatitis (IAD): design and evaluation of psychometric properties of the Ghent Global …

2018

Background Incontinence-associated dermatitis (IAD) is a specific type of irritant contact dermatitis with different levels of severity. An internationally accepted instrument to assess the severity of IAD in adults with established diagnostic accuracy, agreement, and reliability is needed to support clinical practice and research.Objectives To design and psychometrically evaluate the Ghent Global IAD Categorisation Tool (GLOBIAD).Methods The design was based on expert consultation using a three-round Delphi procedure with 34 experts from 13 countries. The instrument was tested using IAD photographs reflecting different severity levels in a sample of 823 health professionals in 30 countries…

AdultMalemedicine.medical_specialtyInternationalityPsychometricsPsychometricsFleiss' kappaDermatologySensitivity and SpecificitySeverity of Illness Index030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineTerminology as TopicSeverity of illnessMedicineHumans030212 general & internal medicineLanguageObserver Variationbusiness.industryIntra-rater reliabilityReference StandardsConfidence interval3. Good healthInter-rater reliabilityUrinary IncontinenceCategorization030220 oncology & carcinogenesisPhysical therapyDermatitis IrritantFemalebusinessKappa
researchProduct

Technical note: a comparison of central and peripheral intraocular pressure using rebound tonometry

2007

Purpose: To compare central and peripheral intraocular pressure (IOP) readings obtained with rebound tonometry.Methods: Intraocular pressure was measured on the right eye of 153 patients (65 males, 88 females), aged from 21 to 85 years (mean +/- S.D., 55.5 +/- 15.2 years) with the ICare rebound tonometer at centre, and 2 mm from the limbus (in the nasal and temporal regions along the 0-180O corneal meridian).Results: Intraocular pressure values obtained with the ICare were 14.9 +/- 2.8; 14.1 +/- 2.5 and 14.5 +/- 2.7 mmHg at centre, nasal and temporal corneal locations, respectively. On average, nasal and temporal IOP readings were 0.75 and 0.37 mmHg lower than the central reading (p 0.05, r…

AdultMalemedicine.medical_specialtyIntraocular pressuregenetic structuresSensitivity and SpecificityICare((R))Cornea03 medical and health sciencesTonometry Ocular0302 clinical medicineReference ValuesOphthalmologyCorneamedicineHumansIntraocular PressureAgedAged 80 and overScience & Technologybusiness.industryReproducibility of ResultsTechnical noteREBOUND TONOMETRYMiddle AgedSensory Systemseye diseasesPeripheralOphthalmologymedicine.anatomical_structureMeridian (perimetry visual field)Temporal RegionsReference values030221 ophthalmology & optometryFemalerebound tonometrysense organsICare®corneal structureperipheral tonometrybusiness030217 neurology & neurosurgeryOptometryintraocular pressure
researchProduct

[Prognostic value of interleukin 6 for death of patients with sepsis].

2016

Abstract Background and objective To see the influence of interlukin-6 (IL-6) as an inflammatory mediator in patients with systemic inflammatory response syndrome (SIRS) and sepsis, assessing whether their serum levels during their stay in intensive care unit (ICU) serve as an early mortality prognostic marker. Material and methods A prospective observational cohort study with 203 ICU patients from a third level hospital. A descriptive analysis was made, X 2 test used to compare qualitative variables, T -Student test to compare quantitative ones. We made a logistic regression multivariant analysis on admission, third and seventh day of stay with dependent variable mortality and independent …

AdultMalemedicine.medical_specialtyLogistic regressionSensitivity and SpecificitySeverity of Illness Indexlaw.inventionSepsis03 medical and health sciences0302 clinical medicinelawInternal medicineSepsismedicineHumans030212 general & internal medicineLongitudinal StudiesProspective StudiesSurvival analysisAgedAged 80 and overAPACHE IIbusiness.industryInterleukin-6030208 emergency & critical care medicineMiddle Agedmedicine.diseasePrognosisIntensive care unitSurgerySystemic inflammatory response syndromeLogistic ModelsEtiologyFemalebusinessBiomarkersCohort studyMedicina clinica
researchProduct

Effect of Kernels Used for the Reconstruction of MDCT Datasets on the Semi-Automated Segmentation and Volumetry of Liver Lesions

2014

Purpose: To evaluate the effect of different reconstruction kernels on the semi-automated segmentation of liver lesions in MDCT. Materials and Methods: A total 62 liver lesions were measured by three independent radiologists with the semi-automated segmentation software Oncology-Prototype (Fraunhofer MEVIS, Siemens Healthcare, Germany) using MDCT datasets (3-mm slice thickness, 2-mm increment) reconstructed with standard, soft and detailed kernels (Philips B, A and D). To ensure objective measurements, only lesions with satisfactory initial segmentation were included, and manual correction was not used. The effective diameter and volume were recorded for each lesion. Segmentation in the sof…

AdultMalemedicine.medical_specialtyLung NeoplasmsInitial SeedAutomated segmentationBreast NeoplasmsTumor responseSensitivity and SpecificityMultidetector Computed TomographyImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingSegmentationTumor growthAgedMathematicsAged 80 and overbusiness.industryLiver NeoplasmsPattern recognitionSpiral Cone-Beam Computed TomographyGold standard (test)Middle AgedTumor BurdenEffective diameterLiverKernel (statistics)FemaleArtificial intelligenceRadiologyColorectal NeoplasmsbusinessSoftwareRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

MRI in lung transplant recipients using hyperpolarized 3He: comparison with CT.

2002

PURPOSE To elucidate the ability of 3He-MRI to detect ventilation defects in lung transplant recipients, 3He-MRI was compared to CT for concordance. MATERIALS AND METHODS We examined 14 lung recipients using 3He-MRI on a 1.5 T MR scanner. CT served as a reference method. Up to four representative ventilation defects were defined for each lung on 3He-MRI and compared to corresponding areas on CT. RESULTS Altogether, 59 representative ventilation defects were defined on 3He-MRI. Plausible CT correlates were found for 29 ventilation defects; less plausible CT correlates were found for eight defects. In 22 defects (37%) no corresponding CT changes were detected. CT demonstrated correlates for v…

AdultMalemedicine.medical_specialtyLungbusiness.industryConcordanceEarly detectionBronchiolitis obliteransMiddle Agedmedicine.diseaseHeliumMagnetic Resonance ImagingSensitivity and Specificitymedicine.anatomical_structuremedicineBreathingHumansRadiology Nuclear Medicine and imagingFemaleRadiologybusinessPulmonary VentilationTomography X-Ray ComputedLungLung TransplantationJournal of magnetic resonance imaging : JMRI
researchProduct

Masseter reflex and blink reflex abnormalities in Chiari II malformation.

2001

Masseter reflex and blink reflex were evaluated in 64 patients with a myelomeningocele and Chiari II malformation. In 46 patients, no brainstem signs or symptoms were present. Brainstem dysfunction related to Chiari II malformation occurred in 18 patients. The masseter reflex was more frequently abnormal in the symptomatic than asymptomatic patients (P = 0.02). Although the blink reflex was similarly affected in the two groups of patients (P > 0.1), it was very sensitive, being abnormal in 83% of symptomatic and 65% of asymptomatic patients. Concomitant abnormality of masseter reflex and the late contralateral blink reflex component (R2c) was almost exclusively found in symptomatic patients…

AdultMalemedicine.medical_specialtyMeningomyeloceleAdolescentPhysiologyAsymptomaticSensitivity and SpecificityCentral nervous system diseaseCellular and Molecular NeurosciencePhysiology (medical)medicineHumansCorneal reflexChildChi-Square DistributionBlinkingMasseter MuscleElectrodiagnosismedicine.diseaseElectric StimulationSurgeryArnold-Chiari MalformationAnesthesiaConcomitantCiliospinal reflexChild PreschoolFemaleNeurology (clinical)Brainstemmedicine.symptomAbnormalityPsychologyJaw jerk reflexMusclenerve
researchProduct

Diagnostic accuracy of current sonographic criteria for the detection of outflow abnormalities in the internal jugular veins

2012

Objectives: This study was aimed at evaluation of the diagnostic value of Doppler sonography for the assessment of abnormalities in the internal jugular veins (IJVs). Method: One hundred and sixteen IJVs were assessed in 58 patients with associated multiple sclerosis. Findings of Doppler sonography were compared with results of the reference test: catheter venography. Results: At least one positive extracranial sonographic criterion suggesting venous abnormality was found in 92.2% of the assessed veins. Yet, sensitivity, specificity, positive and negative predictive values of sonography were low: 93.4%, 12.0%, 79.4% and 33.3% for at least one positive criterion, and for at least two positiv…

AdultMalemedicine.medical_specialtyMultiple SclerosisDiagnostic accuracySensitivity and SpecificitymedicineHumansUltrasonography Doppler ColorAgedphlebographybusiness.industryDoppler ultrasonoundGeneral MedicineMiddle Agedmedicine.diseaseDoppler sonographyFemaleOutflowDoppler ultrasoundRadiologyJugular VeinsCardiology and Cardiovascular MedicineVenous malformationbusinessvenous malformationPhlebology : the journal of venous disease
researchProduct